• 제목/요약/키워드: Operating condition

Search Result 3,034, Processing Time 0.03 seconds

Clearance Variation Effects on Micro Wave Rotor Operation

  • Okamoto, Koji;Yamaguchi, Kazuo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.855-861
    • /
    • 2008
  • Micro wave rotor is expected to improve the performance of micro gas turbines drastically. In the present study, a micro wave rotor test rig was designed and built for micro gas turbines of 1-10 kW output range, and its test runs were carried out with cold air flow. In the previous experiments, the leakage loss had large influence on its operating condition. Therefore, abradable coating was applied on the end walls to achieve the operation with zero clearance for leakage reduction and its improvement on the operating condition is discussed in this study.

  • PDF

Present condition and Improvement of Citizen Monitor System of Railway Operation Companies (철도운영회사의 모니터 제도 운영 현황 및 개선 방향)

  • Han, Woo-Jin;Park, Jeong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.770-775
    • /
    • 2008
  • Currently most domestic passenger railway transportation companies are operating citizen monitor system. The citizen monitor is the system to grasp the passengers' inconvenience and proposals in depth and to collect improvement methods based on those. But the present citizen monitor system has little difference from general complaint processing system, so it is necessary to improve to correspond its original purpose. Therefore in this paper, based on my citizen monitor experience of many years and literature investigation, I will summarize present condition of the operation of citizen monitor system, grasp its problems and propose improvement point of citizen monitor system. By these improvement, the effectiveness of citizen monitor system per expense will increase, and ultimately it can be contributed to public relations and service advancement of railway operating companies.

  • PDF

An investigation on the heating energy consumption and operating condition in apartment houses (공동주택의 에너지소비량 및 난방운전 실태에 관한 조사연구)

  • 신용태
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.45-50
    • /
    • 1994
  • The energy consumption in apartment houses is investigated according to the heating systems, that is, district, central, and individual heating systems. And, operating conditions of intermittent heating are surveryed and analysed in the central heating systems. As a result, each annual energy consumption of district, central and individual heating system is 143.56 Mcal/m2year, 216.78 Mcal/m2year and 150.68 Mcal/m2year, Also, the heating is generlly started at 04:00 and 17:00 of each day, and the heating system is operated for 2~3 hours per each time.

  • PDF

The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona (충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성)

  • 김은호
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.

Development of CMMS for the real-time CBMS (CMMS(Computerized Maintenance Management System)의 실 시간적인 CBMS(Condition Based Maintenance System) 연구)

  • 박주식;박재현;강경식;이광배
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • Equipment and machine of industrial plant are give effect to mechanical-stress of many working-stop or long time operating. Therefore, to be old and decrepit of every king of equipment. As long time operating equipment period into increase conservation and of repair equipment time is efficacious necessity of utility factor gradually that of productivity of diminution and complete equipment expense of increase. Conservation at special skill working and necessity is that will effectually and complete a period prevention management diagnosis can conservation point at issues at in advance.

  • PDF

Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems (혼합송전계통에서 재폐로 시행시 개폐과전압 해석)

  • Lim, Kwang-Sik;Lee, Jong-Boem;Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

Three-Dimensional Thermohydrodynamic Analysis of Journal Bearings Operating in Turbulent Region Using $kappa-varepsilon$ Model (난류상태로 운전되는 저어널베어링에서의 $kappa-varepsilon$ 모델을 이용한 3-차원 THD해석)

  • 이득우;김경웅
    • Tribology and Lubricants
    • /
    • v.3 no.1
    • /
    • pp.39-46
    • /
    • 1987
  • Frictional loss in turbulent regime is abnormally increased compared with in laminar regime. Thus the consideration of temperature rise across fluid film is significant in analysis and conventional isothermal theory loses its usefulness for performance prediction. This paper proposes to the three-dimensional thermohydrodynamic analysis of finite journal bearings operating under turbulent condition using two-equation model($\kappa-\varepsilon$ model) proposed by Hassid & Poreh. The equations are solved numerically by finite difference method. We make the analysis applicable even at large eccentricity when back flow of the lubricants occurs and axial flow is no longer ignored compared to circumferential flow.

Optimization of a semi-batch esterification reactor (반회분 에스테르화 반응기의 최적화)

  • 이융효;박선원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.582-588
    • /
    • 1993
  • A scheme of dynamic optimization for batch reactor his been developed and applied to a semi-batch esterification reactor. To obtain optimal operating conditions for the given semi-batch reactor system with complex reaction kinetic and process constraints, a general nonlinear programming solver and finite element techniques have been introduced. The optimization results for the complex reactor system have been compared with those of Kumar et al. [1984] to show better optimization performance. The proposed optimizing scheme has been applied to the free end time problem to obtain the realistic operating condition. The results can supply valuable information for economic operation of the given batch esterification reactor.

  • PDF

An Experimental Study of Three Buffer Pulse Tube Refrigerator (Three buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성제;고득용;김효봉;신완순
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

An Experimental Study of a Therr Buffer Pulse Tube Refrigerator (Three Buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성재;고득용;김효봉;신완순
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF