• Title/Summary/Keyword: Operating Team

Search Result 572, Processing Time 0.058 seconds

A Study on the Relationships among Nursing Organizational Characteristics, Types of Nursing Organizational Culture and Team Effectiveness at Operating Rooms (수술실의 간호조직특성, 조직문화 유형 및 팀 효과성과의 관계)

  • Kim, Boon-Han;Kim, Yoon-Sook;Jeon, Hye-Won;Kim, Keum-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.3
    • /
    • pp.385-396
    • /
    • 2006
  • Purpose: This study was a literary investigation in the development of an effective team-raised and cultural nursing organization targeting operating room nurses. This was done by grasping organizational features, different types of nursing organizational culture and team effectiveness, and by analyzing the relationships among variables. Method: The participators were 373 nurses. The data was collected between March 10th and April 28th, 2004. SPSS Win 11.0 program was used for data analysis. Results: Results of this study were as follows: A nursing organization at operating rooms was found to have an organizational culture with the characteristic of a centralized power and hierarchy-oriented organizational culture. With respect to a relationship between operating room organizational characteristics and the types of nursing organizational culture, there was a significant correlation in relationship-oriented culture and innovation-oriented culture. In the relation between the types of operating room organizational culture and team-effectiveness, it showed a significant correlation in team-devotion, peer-groupsatisfactional perception of a team's outcome in decreasing order. Conclusion: The organizational characteristic at operating rooms was power centralization and the culture type was hierarchy-oriented. These are factors that have a negative effect on a team-effectiveness-affecting relationship-oriented culture, innovation-oriented culture and work-oriented culture.

  • PDF

Enhancing Lifetime of White OLED Device by Minimizing Operating Voltage Increase

  • Lee, Sung-Soo;Choi, Jun-Ho;Ha, Jae-Kook;Lee, Sang-Pil;Kim, Seong-Min;Choi, Ji-Hye;Lee, Soo-Yeon;Kim, Hyo-Seok;Chu, Chang-Woong;Shin, Sung-Tae;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1658-1660
    • /
    • 2007
  • We fabricate green device having unique life time characteristics of operating voltage reduction with time, ${\Delta}V_{op}$ <0. A green device needs lower voltage than initial voltage for sustaining constant current as life time goes on. It means there are two possible reasons; one is interface modification between anode and HIL due to oxygen plasma treatment and the other is bulk property modification due to combination of new green host and new green dopant. From these materials and oxygen plasma treatment, we can make white OLED device having the characteristics of low ${\Delta}V_{op}$ increasing.

  • PDF

The Trusted Path Authentication System between the User and the Secure OS (사용자와 시스템간의 신뢰경로가 보장되는 인증시스템)

  • Doo, So-Young;Ko, Jong-Gook;Un, Sung-Kyong;Kim, Jeong-Nyeo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.10b
    • /
    • pp.961-964
    • /
    • 2001
  • 인증시스템은 보안운영체제시스템을 구성하기 위한 중요한 서브시스템 중의 하나이다. 본 논문에서는 사용자가 시스템에 접근하기 위해서 가장 먼저 거치게 되는 인증 절차 수행에 있어서 허가된 사용자의 접근만을 허용하고, 인증요청 메시지의 진위 여부를 확인시켜주는 기능과 사용자가 입력하는 중요 정보가 다른 사용자에게 유출되지 않도록 보장하는 기능을 추가한 다 단계 사용자 인증방법을 소개한다. 본 논문에서는 역할기반의 접근제어 시스템을 커널 내부에 구성하고, 사용자인증에 비밀번호와 하드웨어 장치인 스마트카드를 사용함으로써 강화된 사용자 인증 시스템을 구현하였다.

  • PDF

Secure User and Program Interface for SecuROS (SecuROS 에서 개발된 사용자 및 프로그램 인터페이스)

  • Doo, So-Young;Go, Jong-Guk;Eun, Seong-Gyeong;Kim, Jeong-Nyeo;Gong, Eun-Bae
    • The KIPS Transactions:PartC
    • /
    • v.8C no.5
    • /
    • pp.557-564
    • /
    • 2001
  • Many people use Linux and FreeBSD because it is freeware and excellent performance. The open source code is very important feature but it also has some problem which may be attacked by hackers frequently. This paper describes the SecuROS of secure operating system that is best solution to this problem and introduces user and programmer interface for active use of secure operating system. Developed secure operating system is composed of the access control method MAC and ACL and conforms to the POSIX which is universally used.

  • PDF

ESTIMATION TECHNIQUE Of AIR CONTENT IN TUTOMATIC TRANSMISSION FLUID BY MEASURING EFFECTIVE BULK MODULUS

  • Cho, Baek-Hyun;Lee, Hyoun-Woo;Oh, Jong-Sun
    • International Journal of Automotive Technology
    • /
    • v.3 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • It is well known that the entrained air in oil causes appreciable reduction in the stiffness of hydraulic systems. It makes the response delay of the systems and sometimes destroys the stability. Because the hydraulic systems of automatic transmissions are operated in relatively low pressure and high temperature, it is very important to analyze the effects of the air included in automatic transmission fluid. However, it is difficult to derive the generalized model to describe the effective bulk modulus theoretically or measure it in actual operating conditions of automatic transmissions. This paper reviews previous studies of the air effects in hydraulic systems and the measurement techniques of the effective bulk modulus in operating conditions. Based on this work, the theoretical model with moderate complexity and the measurement technique of the effective bulk modulus considering entrained air effect at real operating conditions are suggested. Our paper also shows that the quantity of the entrained air in the automatic transmission fluid can be estimated from the experimental results.

The development of the MMI system for automating steel-making process (제철 공정 자동화를 위한 MMI 시스템 개발)

  • Lee, Dae-Sung;Kim, Yoon-Ha;Joo, Moon-Jab
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2469-2471
    • /
    • 2002
  • MMI 시스템은 제철 공정에서 발생되는 다양한 데이터를 조업자에게 쉽고 빠르게 전달하기 위해, real time operating system에서 동작하는 제철공정의 주된 제어 프로세스와 인터페이스 한다. 따라서 MMI 시스템은 제철 공정의 주된 제어 프로세스와 ethernet network을 통해 공유 데이터들을 통신하도록 개발되고, MMI 시스템은 M/S window operating system과 DDE(Dynamic Data Exchange) 라이브러리 환경을 기반으로 개발된다. 수 개의 MMI client PC와 1 개의 MMI server로 구성되는 MMI 시스템은 MMI client들 사이의 공유 데이터가 동기화될 수 있도록 최적 packet 양을 도출하고, 신뢰성 높은 데이터 전송을 위한 특별한 데이터 핸들링 방법을 사용한다. MMI 시스템은 GUI(Graphic User Interface)를 사용하여 조업자에게 친숙한 window 화면을 제공하므로, MMI 시스템의 화면 수정, 첨가 및 삭제가 비용 부담없이 용이하게 진행되므로, 기존 제철 공정에서 사용하던 OCP(Operating Control Panel)들이 MMI 시스템으로 대체되고 있다.

  • PDF

Performance Test of a 7 tonf Liquid Rocket Engine Turbopump (7톤급 액체로켓엔진용 터보펌프 조립체 성능시험)

  • Kwak, Hyun Duck;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jinhan;Noh, Jun-Gu;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Jeong, Eunhwan;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeong-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • Performance tests of a turbopump for the developing 7-tonf liquid rocket engine were conducted. The performance of turbopump components and their power matching were measured and examined firstly under the LN2 and water environment. In the real propellant(LOX and kerosene) environment tests, design and off-design performances of turbopump were fully verified. During the off-design tests, turbopump running time was set the same as engine operating time and pump inlet pressure were set lower than nominal operating value in order to investigate pump suction capability. It have been verified that subject turbopump satisfies required performance - flow rate, head, suction performance and operational time - in the operating regime of developing liquid rocket engine.

Measuring Situation Awareness of Operating Team in Different Main Control Room Environments of Nuclear Power Plants

  • Lee, Seung Woo;Kim, Ar Ryum;Park, Jinkyun;Kang, Hyun Gook;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.153-163
    • /
    • 2016
  • Environments in nuclear power plants (NPPs) are changing as the design of instrumentation and control systems for NPPs is rapidly moving toward fully digital instrumentation and control, and modern computer techniques are gradually introduced into main control rooms (MCRs). Within the context of these environmental changes, the level of performance of operators in a digital MCR is a major concern. Situation awareness (SA), which is used within human factors research to explain to what extent operators of safety-critical systems know what is transpiring in the system and the environment, is considered a prerequisite factor to guarantee the safe operation of NPPs. However, the safe operation of NPPs can be guaranteed through a team effort. In this regard, the operating team's SA in a conventional and digital MCR should be measured in order to assess whether the new design features implemented in a digital MCR affect this parameter. This paper explains the team SA measurement method used in this study and the results of applying this measurement method to operating teams in different MCR environments. The paper also discusses several empirical lessons learned from the results.