• 제목/요약/키워드: Operating Status

검색결과 957건 처리시간 0.035초

AGV 시스템의 운영기술 개발 (Development of Operating Technology for AGV System)

  • 송준엽;이승우;이현용
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.27-38
    • /
    • 1992
  • We deals with stationary layout control system of AGV. It is a intelligent control system to he wholly charged control PC a layout information and guided command and to be controlled a vehicle driving, steering, safety of natural functions of AGV. Fieldbus concentrator of stationary layout control system serves control command from control PC and status information of AGV. Telegram software monitors transmitted command and status information through IR(JnfraRed) modem. Especially it is possible to easily network to use not an exclusive controller of AGV but personal computer(PC) when communicate and interface a different kind of controller.

  • PDF

CTC 상태감시 데이터 해석기법 (Analysis Method of CTC Status Monitoring)

  • 최규형;정의진;강규현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.273-279
    • /
    • 1999
  • The main purpose of this study is to develope a Simulator for Central Traffic Controller(CTC) which can check the operating status of CTC and support tile maintenance procedure. The simulator supervise the CTC processor units and the data transmission between the CTC modules and the railway station equipments to define the validity of system functions and notify whether the eqipments are good or not. With the help of the simulator we could detect the error of CTC equipments easily. repair the faults efficiently. and improve tile reliability of CTC system.

  • PDF

HDLC 프로토콜을 채용한 CATV 망감시 시스템 구현에 관한 연구 (A study on the implementation of a CATV status monitoring system using HDLC protocol)

  • 김내진;김진태;박인갑
    • 전자공학회논문지A
    • /
    • 제31A권10호
    • /
    • pp.10-20
    • /
    • 1994
  • This paper presents a CATV SMS (Status Monitoring System) using HDLC (High Level Data Link Contorl) protocol and the system implementation.The system specifications were derived from the analysis of technical status and requirement of the domestic CATV industry. For the interoperability with a global network management system in the future, HDLC protocol was adopted in the system. The system performance was improved by using the communication controller chip and the large data buffer. For reducting the communication problems induced by accumulated noise in up-stream data channels, the system was designed that the different communication channel can be assigned to each proper mass of terminal. The operating software was designed with menu driven user interface and have various functions for the convenience of users. The test result of the implemented system at the experimental network showed good performance and suitability for a coaxial CATV Status Monitoring System.

  • PDF

Physiological Status Assessment of Locomotive Engineer During Train Operation

  • Song, Yong-Soo;Baek, Jong-Hyen;Hwang, Do-Sik;Lee, Jeong-Whan;Lee, Young-Jae;Park, Hee-Jung;Choi, Ju-Hyeon;Yang, Heui-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.324-333
    • /
    • 2014
  • In this study, physiological status of locomotive engineers were measured through EEG, ECG, EDA, PPG and respiration signals from 6 subjects to evaluate their arousal status during train operating. Existence of tunnels and mechanical vibration of train using 3-axes acceleration sensors were recorded simultaneously and were correlated with operator's physiological status. As the result of the analyzed subjects' physiological signals, mean SCR was increased in the section where more body movement is required. The RR interval was decreased before and after train stop due to the higher level of mental tension. The intensity of beta wave of EEG was found to be higher before and after train stop and tunnel section due to the increased mental arousal and tension. Therefore, it is expected that the outcomes of the physiological signals explored in this study can be utilized as the quantitative assessment methods for the arousal status to be used for sleepiness prevention system for vehicles operators which can greatly contribute to public transportation system safety.

퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출 (Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method)

  • 박승규;최성진
    • 한국지능시스템학회논문지
    • /
    • 제22권4호
    • /
    • pp.500-506
    • /
    • 2012
  • 좌심실보조장치의 모델과 안전한 장치 구동을 위한 흡입현상 검출을 위한 방법을 제안한다. 좌심실보조장치인 축류혈액펌프는 심장에 문제가 있는 환자를 보조하기 위하여 사용되어 왔다. 축류혈액펌프는 비맥동성 펌프이며, 맥동성 펌프에 비하여 작은 크기와 효율성과 같은 장점이 있으나, 안전한 펌프 운전 조건을 결정하는 데 어려움이 있다. 축류혈액펌프는 정상상태와 흡입상태와 같은 상이한 펌프 동작 상태를 가지며, 이는 좌심실에서 흡입현상 발생여부에 좌우된다. 퍼지 subtractive 클러스터링 기법을 이용하여, 이와 같은 동작 특성을 가지는 축류혈액펌프 모델을 개발하며, 개발한 펌프 모델을 이용하여 흡입현상 발생 전후의 펌프 혈류량을 추정한다. 또한 퍼지 subtractive 클러스터링 기법을 이용하여 좌심실에서 흡입현상 발생여부를 감지할 수 있는 흡입현상 검출 모델을 개발한다.

공공데이터 포털과 개별 포털 간의 데이터 연계방안 연구 (A Study on Data Linkage Between Public Data Portals and Individual Portals)

  • 박진호 ;한상우
    • 한국비블리아학회지
    • /
    • 제33권4호
    • /
    • pp.249-269
    • /
    • 2022
  • 공공데이터 포털(data.go.kr)은 우리나라 공공데이터 검색과 활용을 위한 통합창구이다. 2021년 행정안전부는 개별 포털 정비방안을 수립한 바 있다. 개별 포털은 공공데이터 외 국내 공공기관들이 구축한 포털을 통칭하는 표현이다. 정비방안에 따라 공공데이터 포털 운영 주체인 한국지능정보사회진흥원은 공공데이터 포털과 개별 포털을 연계하기 위한 운영 및 데이터 연계방안 수립이 필요하다. 이에 본 연구에서는 우리나라 공공데이터 포털, 미국, 영국, 프랑스 데이터 포털 운영현황과 데이터 연계방식을 조사하여 데이터 연계 시 상향식 방법 채택이 효율적임을 제안하였다. 또한, 연계 시 추진해야 하는 구체적인 절차를 데이터 연동 표준방식 결정, 메타데이터 현황분석, 운영 인프라 확충, 데이터 반입 확인, 서비스 개시 5단계로 나누어 제시하였다.

유효성분 동작형 누전차단기(Igc Free ELB)의 원리 및 동작 특성 해석 (Analysis of the Principle and Operation Characteristics of an (Igc-Free ELB) Operated by an Active Component)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.456-461
    • /
    • 2010
  • This study compares the criteria of earth leakage breakers (ELB) and analyzes the characteristics of an Igc-free ELB operated by an active component which is not misoperated by capacitive current. Even for the same ELB, the earth leakage current flowing through the human body is estimated to be differ greatly depending on the power source, voltage, location and status of contact, contact time duration, etc. Earth leakage breakers are classified based on the rated voltage, rated sensing current, rated operating time etc. Mounting and demounting of the existing equipment can be performed easily since an $I_{gc}$-free ELB is manufactured with the same structure as a conventional ELB. The rated operating current of a conventional and an $I_{gc}$-free ELB is 30mA, the sensing current is 25mA and the rated non-operating current is 15mA. In the analysis of non-operating current characteristics, the rated non-operating current of 15mA was satisfied up to a 20mA charging current in the conventional ELB, but does not satisfy the rated non-operating current as it operates when the resistive leakage current is lower than 15mA for a charging current exceeding 20mA. Also, the ELB is misoperated without a resistive leakage current when the charging current exceeded 25mA. However, the newly developed $I_{gc}$-free ELB satisfied the rated non-operating current even when the charging current was 60mA. Also, in comparison to the interrupting characteristics, it was confirmed that the charging current satisfying the rated non-operating current of the $I_{gc}$-free ELB was three times higher than that of the conventional ELB.

수술실 간호사의 병원감염관리 실천정도에 영향을 미치는 요인 (Factors Affecting on the Level of Practice on Nosocomial Infection Management among Operating Room Nurses)

  • 허선;김인숙;김계하
    • 성인간호학회지
    • /
    • 제20권3호
    • /
    • pp.375-385
    • /
    • 2008
  • Purpose: This study is to identify factors affecting on the level of practice on nosocomial infection management of operating room nurses. Methods: The subjects of this study were 155 nurses who worked in operating rooms of six medical centers in located Gwangju and Chonanam area. Data were collected during October, 2006 by the questionnaire including a total of 124 questions. Data collected were analysed with use of SPSS 12.0 program. Results: There was a significant difference of the level of practice by marital status(t=3.957, p=.048), education level(F=3.691, p=.027), position(F=6.588, p=.002), type of hospital(t=4.857, p=.029), number of nurse(F=4.243, p=.007), education about nosocomial infection management(F=3.069, p=.030), management council(t=6.397, p=.012) and management manual(t=6.961, p=.009). There were significant correlations between knowledge and practice (r=.389, p=.000), and between awareness and practice(r=.389, p=.000). Knowledge on nosocomial infection management, awareness of hands washing and positions were affecting factors on the level of practice. Conclusion: This study suggests that knowledge and awareness on nosocomial infection prevention and management of operating room nurses should be improved through consistent education. and support of administrator's of hospitals is needed.

  • PDF

지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로 (A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권4호
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

간호인력배치유형에 따른 수술실 간호사의 업무수행능력 및 직무만족 (Competency of Nursing Performance and Job Satisfaction of Operating Room Nurse by Type of Nurse Staffing)

  • 안영미;박재순
    • 여성건강간호학회지
    • /
    • 제11권2호
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: This study was designed to investigate the relationships of the types of nurse staffing, the competency of nursing performance and job satisfaction by analyzing the types of nurse staffing in operating room. Method: The subjects were 472 nurses who work in operating room. The instruments used in this study were three tools: competency of nursing performance, job satisfaction and type of nurse staffing. Result: Type 4 was most in the type of nurse staffing of the subjects. According to the type of nurse staffing, the competency of nursing performance was significantly different. There was significant difference in the competency of nursing performance according to age, marital status, bachelor, employ, position, and career, and job satisfaction according to age, position, and career. In opinion about the ideal type of nurse staffing, type 2 was most regardless of career. Conclusion: Type 4 which has lower competency of nursing performance was adopted in many hospitals now but, type 2 which has highest competency of nursing performance was selected by many nurses as the best one. So, it should be considered the type of nurse staffing of in operating room and change it.

  • PDF