KHNP-JIT Development for the Effective Use of Nuclear Power Plant Operating Experiences (원자력발전소 운전경험 활용 증진을 위한 KHNP-JIT 개발)

  • Hur, Nam Young;Lee, Sang Hoon;Kim, Je Hun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.31-34
    • /
    • 2013
  • According to the increase in numbers and operation time of domestic Nuclear Power Plants, KHNP(Korea Hydro & Nuclear Power) has many operating experiences. These show that most of the accidents repeatedly occurred not by the new sources or mechanism like the Fukushima Accident, but by the human and equipment errors from normal habits, process, design, maintenance etc.. These lessons show that the well-established systematic approach is requested to take lessons from past experiences. For this reason, developed countries established INPO, WANO, COG as a non-profit professional organizations to actively share their operating experiences. KHNP is also trying to promote the utilization of operating experiences. As part of this effort, KHNP is developing the KHNP-JIT, reflecting the overseas JIT and the domestic experiences.

Effects of the Hydrostatic Test and the Operating Condition on Weld Residual Stress at a Safety Nozzle of the Pressurizer (수압시험 및 운전조건이 가압기 안전노즐의 용접잔류응력에 미치는 영향 평가)

  • Lee, Kyoung Soo;Lee, Sung Ho;Kim, Wan Jae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • This paper presents the results of finite element analysis for the effects of hydrostatic test and operating condition on the weld residual stress at dissimilar metal weld of a pressurizer safety nozzle in a nuclear power plant. For the study, the weld residual stress at ambient condition was analyzed using ABAQUS in the first place. After the weld residual stress analysis, the hydrostatic test condition and operating condition was applied to the same model one after another. The weld residual stress was observed to change due to the successive hydrostatic test and operating condition. The axial residual stresses on inner surface of the dissimilar metal weld and HAZ region were decreased by hydrostatic test and operating condition, which gives beneficial effect on preventing primary water stress corrosion cracking.

Stress Analysis and Evaluation of Steam Separator of Heat Recovery Steam Generator (HRSG) (배열회수보일러 기수분리기의 응력해석 및 평가)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.23-31
    • /
    • 2018
  • Stress of a steam separator, equipment of the high-pressure (HP) evaporator for a HRSG, was analyzed and evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the analysis results of the piping system model of the HP evaporator, reaction forces of the riser tubes connected to the steam separator, i.e., nozzle loads, were derived. Next, a finite element model of the steam separator was constructed and analyzed for the design pressure and the nozzle loads. The results show that the maximum stress occurred at the bore of the riser nozzle. The primary membrane stresses at the shell and nozzle were found to be less than the allowable stress. Next, the steam separator was analyzed for the steady-state operating conditions of operating pressure, operating temperature, and nozzle loads. The maximum stress occurred at the bore of the riser nozzle. The primary plus secondary membrane plus bending stress at the shell and nozzle was found to be less than the allowable stress.

An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구)

  • Park, Cha-Sik;Jung, Tae-Hun;Joo, Young-Ju;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.

A Study on the Improvement of Dynamic Characteristics of ABS Outlet Valve (ABS 출구 밸브의 동특성 향상에 관한 연구)

  • 김병우;송창섭;이용주
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.133-142
    • /
    • 2002
  • To improve the hydraulic control performance of ABS, it is necessary to establish an efficient control algorithm. And also it is necessary to ova]Hate a hydraulic modulator with solenoid valve quantitatively. In this paper, FEM and permeance method are used to analyze dynamic characteristics of outlet valve. In return, mathmatical modeling of a hydraulic modulator and operating pressure is presented, and the model parameters of an outlet valve are moving plunger, spring constant and orifice diameter. This study shows the way to improve the dynamic characteristic of an ABS outlet valve heavily depending on operating pressure. It is recommended that operating pressure should be justified at the first step toward the design to get the optimal design of an outlet valve.

Operating Pressure Conditions for Non-Explosion Hazards in Plants Handling Propane Gas

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.493-497
    • /
    • 2020
  • Hazardous area classification is designed to prevent chemical plant explosions in advance. Generally, the duration of the explosive atmosphere is used for zone type classification. Herein, IEC code, a quantitative zone type classification methodology, was used to achieve Zone 2 NE, which indicates a practical non-explosion condition. This study analyzed the operating pressure of a vessel handling propane to achieve Zone 2 NE by applying the IEC code via MATLAB. The resulting zone type and hazardous area grades were compared with the results from other design standards, namely API and EI codes. According to the IEC code, the operating pressure of vessels handling propane should be between 101325-116560.59 Pa. In contrast, the zone type classification criteria used by API and EI codes are abstract. Therefore, since these codes could interpret excessively explosive atmospheres, care is required while using them for hazardous area classification design.

Characterization of Nitrogen Gas Crossover in PEM Fuel Cell Stacks (고분자 연료전지 스택에서 질소 크로스오버 특성에 관한 연구)

  • Baik, Kyung-Don;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.207-214
    • /
    • 2009
  • Crossover of nitrogen from cathode to anode is inevitable in typical membranes used in PEM fuel cells. This crossovered nitrogen normally accumulates in the hydrogen recirculation system at anode side channels. Excessive buildup of nitrogen in the anode side lowers the relative hydrogen concentration and finally affects the performance of fuel cell stack. So it is very important to analysis the nitrogen gas crossover at various operating conditions. In this study, characterization of nitrogen gas crossover in PEM fuel cell stack was investigated. The mass spectroscopy (MS) has been applied to measure the amount of the crossovered nitrogen gas at the anode exit. Results show that nitrogen gas crossover rate was affected by current density, anode and cathode stoichiometric ratio and operating pressure. Current density, anode stoichiometric ratio and anode operating pressure do not affect nitrogen crossover rate but anode exit concentration of nitrogen. Cathode pressure and stoichiometric ratio largely affect the nitrogen crossover rate.

Comparisons of Performance with Heat Exchanger Constitution in the Fin-tube Gascooler (핀-관 가스쿨러에서 열교환기 구성에 따른 성능 비교)

  • Bae, Kyung-Jin;Shin, Eun-Sung;Hong, Myung-Suk;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1294-1299
    • /
    • 2009
  • Since the operating pressure of $CO_2$ gascooler is so high compared with that of previous subcritical condenser, the optimization of gascooler is needed for improve heat exchanger performance. In this study, the performance characteristics of five kinds of heat exchangers were analyzed and compared with operating conditions. As a result, the 4-20 HX-tube shows the maximum gascooler capacity because the heat transfer is effective and pressure drop is small. Beside, the high performance of 4-20 HX-tube could be keep for wide operating condition.

  • PDF

An Experimental Study on the Variable Sonic Ejector System (가변형 음속 이젝터 시스템에 관한 실험적 연구)

  • Lee, Jun-Hee;Jung, Sung-Jae;Kim, Heuy-Dong;Koo, Byoung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2035-2040
    • /
    • 2004
  • A cone cylinder is used to obtain variable operation conditions for the sonic ejector-diffuser system. The cone cylinder is designed to move upstream and downstream to change the ejector throat area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream for the variable sonic ejector system. In experiment, the ejector throat area is varied in the range from ${\psi}=11.88$ to 66.69, and the operating pressure ratio from $p_{0p}/p_a=1.25$ to 9.0. The results show that the variable sonic ejector system is suitable for a required entrainment ratio of secondary stream by altering the ejector throat area ratio and operating pressure ratio.

  • PDF

A Study of a Variable Sonic Ejector Flow

  • Lee, Jun-Hee;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.414-417
    • /
    • 2004
  • A cone cylinder is used to obtain variable operation conditions for the sonic ejector-diffuser system. The cone cylinder is designed to be shifted upstream and downstream to change the ejector throat area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream for the variable sonic ejector system. The study is carried out experimentally. The ejector throat area is varied at the range from Ψ= 11.88 to 66.69, and the operating pressure ratio is changed from $P_{op}$ / $P_{a}$=1.25 to 9.0. The results show that the variable sonic ejector system can be operated to obtain specific entrainment ratio of secondary stream by altering the ejector throat area ratio and operating pressure ratio.o.

  • PDF