• Title/Summary/Keyword: Operating Method

Search Result 6,071, Processing Time 0.031 seconds

Study on Optimization of Operating Conditions for High Temperature PEM Fuel Cells Using Design of Experiments (실험계획법을 이용한 고온 고분자 전해질 막 연료전지의 운전조건 최적화 연구)

  • Kim, Jintae;Kim, Minjin;Sohn, Youngjun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.50-60
    • /
    • 2013
  • High temperature proton exchange membrane fuel cells (PEMFCs) using phosphoric acid (PA) doped polybenzimidazole (PBI) membranes have been concentrated as one of solutions to the limits with traditional low temperature PEMFCs. However, the amount of reported experimental data is not enough to catch the operational characteristics correlated with cell performance and durability. In this study, design of experiments (DOE) based operational optimization method for high temperature PEMFCs has been proposed. Response surface method (RSM) is very useful to effectively analyze target system's characteristics and to optimize operating conditions for a short time. Thus RSM using central composite design (CCD) as one of methodologies for design of experiments (DOE) was adopted. For this work, the statistic models which predict the performance and degradation rate with respect to the operating conditions have been developed. The developed performance and degradation models exhibit a good agreement with experimental data. Compared to the existing arbitrary operation, the expected cell lifetime and average cell performance during whole operation could be improved by optimizing operating conditions. Furthermore, the proposed optimization method could find different new optimal solutions for operating conditions if the target lifetime of the fuel cell system is changed. It is expected that the proposed method is very useful to find optimal operating conditions and enhance performance and durability for many other types of fuel cell systems.

Maximum Torque per Ampere Control of Interior Permanent Magnet Synchronous Motor based on Signal Injection (실시간 신호 주입을 이용한 매입형 영구자석 동기 전동기의 단위 전류당 최대 토크 제어)

  • Kim, Sung-Min;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.142-149
    • /
    • 2010
  • Interior Permanent Magnet Synchronous Motor(IPMSM) have gained an increasing popularity in recent years for a variety of industrial applications, because of their high power density, high efficiency and possibility of flux weakening operation. Because the efficiency of IPMSM is one of the important performance characteristic, the Maximum Torque Per Ampere(MTPA) operating method has been indispensible. In theory, MTPA operating point can be calculated using the exact values of the machine parameters. However, the values of the IPMSM parameters are known to vary widely according to the operating condition. Therefore, to operate the IPMSM in the MTPA operating point, the machine parameters should be estimated in real-time. In this paper, the new MTPA operating method based on the signal injection is presented. By injecting the high frequency current signal, the MTPA operating criteria can be calculated by measuring the input power to IPMSM. The proposed method can find the MTPA operating point with simple signal processing regardless of the parameter variation.

Probabilistic Method for The Harmonic Analysis of Railroad Feeding System (철도급전시스템의 고조파 평가를 위한 확률론적 방법)

  • Lee, Seung-Hyuk;Song, Hak-Seon;Lee, Jun-Kyong;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.384-391
    • /
    • 2006
  • The harmonic currents generated along with the operating speed of electrical railroad traction are very difficult to analyze because of its nonlinear characteristics. This paper therefore presents probabilistic approach for the evaluation of harmonic currents about the operating speed of the arbitrary single traction. To use probabilistic method for railroad system, PDF(Probability Density Function) using measuring data based on the realistic h 따 monic currents per operating speed is calculated. Measuring data of harmonic current per operating speed is obtained using the result data of PSCAD/EMTDC dynamic simulation based on an IAT(Intra Airport Transit) in Incheon International Airport. The means(expected values) and variances of harmonic currents of single traction also are obtained by the PDF of the operating traction speed and harmonic currents. The uncertainty of harmonic currents can be calculated through the mean and variance of PDF. The probability of harmonic currents generated with the operating of arbitrary many tractions is calculated by the convolution of functions. The harmonics of different number of tractions are systematically investigated to assess the TDD(Total Demand Distortion) for the railroad system. The calculation of TDD was carried out using Monte-Carlo Simulations(MSCs) and the results of TDD evaluation of the power quality in the IAT power feeding system.

Study of combinations of site operating states for multi-unit PSA

  • Yoo, Heejong;Jin, Kyungho;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3247-3255
    • /
    • 2021
  • As Probabilistic Safety Assessments (PSAs) are thoroughly conducted for the Site Operating States (SOSs) for a single unit, multi-unit Probabilistic Safety Assessments (MUPSAs) are ongoing worldwide to address new technical challenges or issues. In South Korea, the determination of the site operating states for a single site requires a logical approach with reasonable assumptions due to the fact that there are 4-8 operating units for each site. This paper suggests a simulation model that gives a reasonable expectation of the site operation states using the Monte-Carlo method as a stochastic approach and deterministic aspects such as operational policies. Statistical hypothesis tests were conducted so that the reliance of the simulation results can be guaranteed. In this study, 7 units of the Kori site were analysed as a case study. The result shows that the fraction of full power for all 7 units is nearly 0.45. For situations when more than two units are not in operation, the highest fraction combination was obtained for Plant Operation State (POS) 8, which is the stage of inspection and repairment. By entering various site operation scenarios, the simulation model can be used for the analysis of other site operation states.

Modeling & Operating Algorithm of Hybrid Generation System with PMSG Wind Turbine, Diesel Generator and BESS (영구자석형 풍력-디젤-BESS 복합발전시스템 모델링 및 운전제어 알고리즘에 관한 연구)

  • Oh, Joon-Seok;Jeong, Ui-Yong;Park, Jong-Ho;Park, Min-Su;Kim, Jae-Eon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.724-729
    • /
    • 2016
  • Nowadays high-cost energy storage system using flywheel or secondary battery is applying to hybrid generation system with WT(Wind Turbine) and diesel generator in island areas for stable operation. This paper proposes an operating algorithm and modeling method of the hybrid generation system that can operate for variable wind speed and load, which is composed of energy storage system, variable-speed PMSG(Permanent Magnet Synchronous Generator) WT and diesel generator applied in island areas. Initially, the operating algorithm was proposed for frequency and voltage to be maintained within the proper ranges for load and wind speed changes. Also, the modeling method is proposed for variable speed PMSG WT, diesel generator and BESS(Battery Energy Storage System). The proposed operating algorithm and modeling method were applied to a typical island area. The frequency and voltage was kept within the permissible ranges and the proposed method was proven to be appropriate through simulations.

Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms (태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships (축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정)

  • Jeong, T.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

A VALIDATION METHOD FOR EMERGENCY OPERATING PROCEDURES OF NUCLEAR POWER PLANTS BASED ON DYNAMIC MULTI-LEVEL FLOW MODELING

  • QIN WEI;SEONG POONG HYUN
    • Nuclear Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.118-126
    • /
    • 2005
  • While emergency operating procedures (EOPs) occupy an important role in the management of various abnormal situations in nuclear power plants (NPPs), current technology for the validation of EOPs still largely depends on manual review. A validation method for EOPs of NPPs is thus proposed based on dynamic multi-level flow modeling (MFM). The MFM modeling procedure and the EOP validation procedure are developed and provided in the paper. Application of the proposed method to EOPs of an actual NPP shows that the proposed method provides an efficient means of validating EOPs. It is also found that the information on state transitions in MFM models during the management of abnormal situations is also useful for further analysis on EOPs including their optimization.

Efficient Lambda Logic Based Optimisation Procedure to Solve the Large Scale Generator Constrained Economic Dispatch Problem

  • Adhinarayanan, T.;Sydulu, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.301-309
    • /
    • 2009
  • A simple and efficient Lambda logic (${\lambda}-logic$) based algorithm is proposed for the solution of the generator constrained economic dispatch problem when the generating units having prohibited zones. The proposed method solves the economic dispatch (ED) problem that takes into account ramprate limits, transmission losses and prohibited operating zones in the power system operation. The proposed method uses a simple heuristic rule based on average power of prohibited operating zones which produces the feasibility of solution for the restricted operating units. The effectiveness of the algorithm is tested on five different test systems and the performance compared with other relevant methods reported in the literature. In all the cases, the proposed algorithm performs better than the previous existing algorithms with a less computational burden.

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.