• Title/Summary/Keyword: Operating Method

Search Result 6,089, Processing Time 0.028 seconds

AIT: A method for operating system kernel function call graph generation with a virtualization technique

  • Jiao, Longlong;Luo, Senlin;Liu, Wangtong;Pan, Limin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.2084-2100
    • /
    • 2020
  • Operating system (OS) kernel function call graphs have been widely used in OS analysis and defense. However, most existing methods and tools for generating function call graphs are designed for application programs, and cannot be used for generating OS kernel function call graphs. This paper proposes a virtualization-based call graph generation method called Acquire in Trap (AIT). When target kernel functions are called, AIT dynamically initiates a system trap with the help of a virtualization technique. It then analyzes and records the calling relationships for trap handling by traversing the kernel stacks and the code space. Our experimental results show that the proposed method is feasible for both Linux and Windows OSs, including 32 and 64-bit versions, with high recall and precision rates. AIT is independent of the source code, compiler and OS kernel architecture, and is a universal method for generating OS kernel function call graphs.

Performance Prediction of a Micro Gas Turbine Cogeneration System Using Correction Curves and its Applications (보정곡선을 이용한 마이크로가스터빈 열병합발전시스템의 성능예측과 활용)

  • Choi, Byeong Seon;Kim, Jeong Ho;Kim, Min Jae;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.27-35
    • /
    • 2016
  • The purpose of this study is to develop a method to predict the performance and economics of a micro gas turbine cogeneration system using performance correction curves. The variables of correction curves are ambient temperature, ambient pressure, relative humidity and load fraction. All of the values of correction factors were expressed as relative values with respect to design values at the ISO conditions. Once the correction curves are obtained, system performance can be predicted relatively easily compared to a detailed performance analysis method through a simple multiplication of the correction factors of various variables at any operating conditions. The predicted results using the correction curve method were compared with those by the detailed and more complex performance analysis in a wide operating range, and its feasibility was confirmed. To illustrate the usability of the correction curve method, the results of an economic analysis of a cogeneration system considering varying operating ambient condition and load was presented.

A Novel System for Detecting Adult Images on the Internet

  • Park, Jae-Yong;Park, Sang-Sung;Shin, Young-Geun;Jang, Dong-Sik
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.5
    • /
    • pp.910-924
    • /
    • 2010
  • As Internet usage has increased, the risk of adolescents being exposed to adult content and harmful information on the Internet has also risen. To help prevent adolescents accessing this content, a novel detection method for adult images is proposed. The proposed method involves three steps. First, the Image Of Interest (IOI) is extracted from the image background. Second, the IOI is distinguished from the segmented image using a novel weighting mask, and it is determined to be acceptable or unacceptable. Finally, the features (color and texture) of the IOI or original image are compared to a critical value; if they exceed that value then the image is deemed to be an adult image. A Receiver Operating Characteristic (ROC) curve analysis was performed to define this optimal critical value. And, the textural features are identified using a gray level co-occurrence matrix. The proposed method increased the precision level of detection by applying a novel weighting mask and a receiver operating characteristic curve. To demonstrate the effectiveness of the proposed method, 2850 adult and non-adult images were used for experimentation.

CNC Torch Path Generation for Laser Cutting of Planar Shapes (2차원 자유형상의 레이저 절단을 위한 CNC 공구경로 생성)

  • Park, Hyung-Jun;Ahn, Dong-Gyu
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.3
    • /
    • pp.153-162
    • /
    • 2007
  • In this paper, we propose a knowledge-based method for generating CNC torch path for laser cutting of the outlines of planar shapes. The proposed method consists of two main phases: laser cutting knowledge construction and CNC torch path generation using the knowledge. In the first phase, cutting experiments are conducted on various operating parameters, and then empirical data are stored and analyzed to make up the knowledge of laser cutting. With this knowledge, we can inquire what a kerf width is for specific operating parameters. In the second phase, using the knowledge of laser cutting, CNC torch path is generated for cutting the outlines of the given planar shapes. This phase is basically based on the offset generation of each outline by a sequence of arc splines, where the offset distance is the same as the half of the kerf width determined from the constructed knowledge. The proposed method based on laser cutting knowledge makes full use of arc interpolators in CNC torch path generation. The method can efficiently reduce the number of path segments while keeping the torch path within the desired accuracy.

A Novel Interleaving Control Scheme for Boost Converters Operating in Critical Conduction Mode

  • Yang, Xu;Ying, Yanping;Chen, Wenjie
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Interleaving techniques are widely used to reduce input/output ripples and to increase the power capacity of boost converters operating in critical conduction mode. Two types of phase-shift control schemes are studied in this paper, the turn-on time shifting method and the turn-off time shifting method. It is found that although the turn-off time shifting method exhibits better performance, it suffers from sub-harmonic oscillations at high input voltages. To solve this problem, an intensive quantitative analysis of the sub-harmonic oscillation phenomenon is made in this paper. Based upon that, a novel modified turn off time shifting control scheme for interleaved boost converters operating in critical conduction mode is proposed. An important advantage of this scheme is that both the master phase and the slave phase can operate stably in critical conduction mode without any oscillations in the full input voltage range. This method is implemented with a FPGA based digital PWM control platform, and tests were carried out on a two-phase interleaved boost PFC converter prototype. Experimental results demonstrated the feasibility and performance of the proposed phase-shift control scheme.

Control Method of Distributed-Module Type Photovoltaic Power Conditioners under Stand-alone Operation (분산모듈형 태양광 전력조절기의 독립운전 제어)

  • Seo, Jung-Won;Park, Joung-Hu;Kim, Hye-Rim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.448-457
    • /
    • 2013
  • This paper proposes a control method under stand-alone operating mode for distributed-module type photovoltaic power conditioners. In conventional schemes, there are some problems of a controller saturation in the DC-link (or load) voltage controller when overly-heavy load, light load, and the generated PV power reduction occurs, as well as when a transition occurs from an overly-loaded to normal conditions. To overcome these problems, the proposed controller method switches the main control target from DC-link voltage to the maximum power point, which is closer to the stable operating point when it returns to normal operating conditions. For the analysis, a state-plane trajectory was given and the circuit analysis by PSIM simulation was done. For the verification, a prototype hardware with 110[W] and 50[W] dual photovoltaic modules has been implemented. From the results, it can be seen that PV power tracking is successfully done with the proposed method even under a stand-alone operation mode.

Analysis on operating trends of Protective relay (보호계전기 동작실태 분석)

  • Jang, Sung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.188-190
    • /
    • 2000
  • Protective Relays are vital components of power systems. The role of the protective relaying device is more important than ever. Therefore, We have investigated the operating trends of protective relay from 1991 to 1999. we anticipate that reliability in the power systems increases by improving design, manufacture, construction technology and maintenance method of the protective relay.

  • PDF

Estimation of Harbor Operating Ratio Based on Moored Ship Motion (계류선박의 동요에 기초한 항만가동률 산정)

  • Kwak, Moonsu;Chung, Jaewan;Ahn, Sungphil;Pyun, Chongkun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.651-660
    • /
    • 2006
  • Although a harbor may be constructed with calmness in harbor in mind, which satisfies the design standard, it is frequently reported that the motion of moored ships disrupt the cargo handling. This is because of current design standard, which only deals with the wave height in the decision making process of cargo handling, and, now, a new kind of estimation method of operating ratio for calmness based on the motion of moored ship is in need. In this research, a computational method that analyses the harbor operation rate in harbor was put forward by considering the relation of allowable quantity of motion for cargo handling and the computation of the motion of moored ship at wharf by using moored ship motion analysis model. Here, a new estimetion method was applied at Onsan harbor, and it was compared with the current estimation method, and, then, the difference between the two methods was showed. The harbor operating ratio gained by a new method was dropped by 2~11% at ENE and NE directions when it was compared with the operating ratio based on the current design standard. However, when a harbor structure layout is to be designed, a harbor operating ratio test according to the wave height and a harbor operation rate test, which considers the motion of moored ship, are to be run side by side at a harbor designing process.

A Study on the Estimation Method for the Equipment Operating Costs in the Data Center Outsourcing Environment (데이터 센터 Outsourcing에 있어서 기기 운영비요의 산정 방법에 관한 연구)

  • Hwang, Kyung-Tae;Kwon, Oh-Hun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.6
    • /
    • pp.1401-1417
    • /
    • 1997
  • The major objective of this study is to propose an estimation method for the equipment operating cost in the data center outsourcing situation. To accomplish the objective, the fundamental concepts about the outsourcing pricing is first established by analyzing the previous research in this area. Then an actual case of data center outsourcing is evaluated. Based on the conceptual model and the actual case, a new method is proposed. Validity of the proposed method is verified by the quantitative comparison with the previous method. Reasonability and usefulness of the method were evaluated through the customer survey.

  • PDF

A New Optimal AVR Parameter Tuning Method Using On-Line Excitation Control System Model with SQP Method (온라인 여자제어시스템 모델과 SQP법을 이용한 AVR의 파라미터 튜닝 방법에 관한 연구)

  • Kim, Jung-Mun;Mun, Seung-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.3
    • /
    • pp.118-126
    • /
    • 2002
  • AVR parameter tuning for voltage control of generators has generally been done with the off-line open-circuit model of the synchronous generator. When the generator is connected on-line and operating with load the AVR operates in an entirely different environment from the open-circuit conditions. This paper describes a new method for AVR parameter tuning for on line conditions using SQP(Sequential Quadratic Programming) meshed with frequency response characteristics of linearized on-line system model. As the proposed method uses the un - line system model the tuned parameter sets show more optimal behavior in the on-line operating conditions. furthermore, as this method considers the performance indices that are needed for stable operation as constraints, AVR parameter sets that are tuned by this method could guarantee the stable performance, too.