• Title/Summary/Keyword: Operating Fluid

Search Result 994, Processing Time 0.029 seconds

Rotordynamic Characteristics Analysis for API 610 BB5 Pump Development (API 610 BB5 펌프 개발을 위한 로터다이나믹 특성분석)

  • Kim, Byung-Ok;Lee, An-Sung;Kim, Sung-Ki
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.38-44
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for BB5 eight stages pump as development of API 610 BB5 type pump. Dry-run analytical model, not considering operating fluid, and wet-run analytical model, considering operating fluid are established. In addition, plain circular and pressure dam bearings are chosen and it was discussed that each bearing has an effect on dynamic characteristics of pump rotor system. A rotordynamic analysis includes the critical speed map, Campbell diagram, stability, and unbalance response. As results, it was predicted that rated speed of the pump rotor passes through 1st critical speed in dry-run condition regardless of bearings, however, it was verified that, in wet-run condition, the rotor system doesn't have critical speeds even if more than twice rated speed. Hence the resonance problem caused by the critical speeds does not happen since actual operating is in wet-run condition including operating fluid. As a result of unbalance response analysis, the pump rotor has stable vibration response at rated speed, regardless of operating fluid and the proposed bearing types.

An Investigation on the Torque Converter Characteristics at Various Operating Conditions (작동 조건 변화에 대한 토크 컨버터의 성능 특성 분석)

  • Jang, Wook-Jin;Lee, Chin-Won;Lim, Won-Sik;Park, Yeong-Il;Lee, Jang-Moo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.678-683
    • /
    • 2000
  • The one-dimensional performance model of a torque converter has been widely used to analyze and predict the performance and dynamic behavior of a torque converter. But this model doesn't include the information of the operating fluid properties. Therefore, to precisely predict dynamic performance of a torque converter, the effect of operating conditions must be considered through experimental coefficients such as friction loss coefficient and shock loss coefficient. And these coefficients cannot be achieved without experiments or internal flow analysis. In this study, the effects of varying material properties of operating fluid according to various operating temperatures are clarified with flow analysis of a torque converter. And these results are verified by comparing with those of performance experiment.

  • PDF

Exposure to Blood and Body Fluid in Operating Room Personnel in One Acute Care General Hospital (일개 종합병원 수술실 의료인의 혈액 및 체액 노출 실태조사)

  • Shin, Young Ran;Park, Kwang Ok;Jeong, Jae Sim;Kim, Kyung Mi
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.2
    • /
    • pp.115-126
    • /
    • 2009
  • Purpose: The purpose of this study was to assess the frequency and characteristics of occupational blood and body fluid exposure for operating room personnel during surgical procedures and identify risk factors. Methods: A self-report questionnaire was used to survey 519 operating room personnel who participated in 132 surgeries in an acute care hospital in Seoul between April 12 and 20, 2006. Results: The response rate was 82% (530/646) and analyzed total 519 except for improper 11 questionnaires. Exposure rate was 45.5% (60/132) during operations and 20.4% (106/519) for operating room personnel. By job categories, the exposure rate was as follows; anesthesiologists and nurses 31.2% (44/141), operators and assistants 22.1% (32/145), circulating nurses 12.0% (11/92), scrub nurses 11.4% (14/123). The mucous membrane-eye exposure with a high risk of transmitting infection was 6.6% (7/106) and the most frequent route of exposure was blood and body fluid touching unprotected skin. In multivariate analysis, the risk factors of exposure were services, duration of operation, a patient who had a peripheral arterial catheter line, and job category. Conclusion: Educational programs and appropriate use of personal protective equipment are necessary to prevent operating room personnel from being exposed to blood and body fluid.

Operating condition and air pollutant emission when do RPF co-combustion in coal fluid bed boiler (석탄유동층 보일러에 RPF 혼소시 운전조건 및 대기오염물질 배출 특성 변화)

  • Yoon, Kyoon-Duk;Park, In-Chul;park, Jong-Kyeong;Cho, Yeon-Haeng;Choi, Yeon-Seok;Shun, Do-Won;Park, Do-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.527-530
    • /
    • 2006
  • Because price of fossil fuel rises, necessity about alternative energy was risen. Studied co-combustion of RPF to coal fluid bed boiler by necessity of these althernative energy. Purpose of this study to coal fluid bed bioler RPF when did co-combustion, change operating condition and characteristic of air pollutant examine according to change of fuel characteristic, operating condition examined about combustion chamber temperature, oxygen content etc. and air pollutant examined about material that is included to allowable exhaust standard and dioxin. Co-combustion condition was 5%. It was no peculiar under test result operating condition. Concentration of Co and HCl rose according as do RPF co-combustion and the other pollutants had hardly changed. Dioxin is low concentration level more than $0.1ng-TEQ/Sm^3$. There was no pollutant that exceed akllowable exhaust standard for boiler but $SO_x,\;NO_x$ were exceeded about allowable exhaust standard for incinerating facility.

  • PDF

ESTIMATION TECHNIQUE Of AIR CONTENT IN TUTOMATIC TRANSMISSION FLUID BY MEASURING EFFECTIVE BULK MODULUS

  • Cho, Baek-Hyun;Lee, Hyoun-Woo;Oh, Jong-Sun
    • International Journal of Automotive Technology
    • /
    • v.3 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • It is well known that the entrained air in oil causes appreciable reduction in the stiffness of hydraulic systems. It makes the response delay of the systems and sometimes destroys the stability. Because the hydraulic systems of automatic transmissions are operated in relatively low pressure and high temperature, it is very important to analyze the effects of the air included in automatic transmission fluid. However, it is difficult to derive the generalized model to describe the effective bulk modulus theoretically or measure it in actual operating conditions of automatic transmissions. This paper reviews previous studies of the air effects in hydraulic systems and the measurement techniques of the effective bulk modulus in operating conditions. Based on this work, the theoretical model with moderate complexity and the measurement technique of the effective bulk modulus considering entrained air effect at real operating conditions are suggested. Our paper also shows that the quantity of the entrained air in the automatic transmission fluid can be estimated from the experimental results.

A Study on Heat Transfer Characteristics of Separate Type Heat Pipe with a Rotor (회전자를 갖는 분리형 히트파이프의 열전달특성에 관한 연구)

  • Jun, C.H.;Kim, O.G.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.75-84
    • /
    • 2000
  • The purpose of this research is to study on the heat transfer characteristics of separate type heat pipe with a rotor. The heat transfer characteristics of the rotor condenser are various on input heat of evaporator, rotational speeds of rotor, and working fluid amount. The results obtained from the study are as follows. 1. Magnetic fluid using seal of the rotor operated in stability by a variation of temperature and rotation speeds. The configuration of magnetic fluid seal assembly was adequate. 2. Steam ejector is effective in recovering working fluid condensate in the rotor. When steam ejector is operating, the heat flux of working fluid does not change, with the wall temperature in the rotor. 3. The optimum design conditions on working fluid amount and rotational speeds are effective in evaporator volume 50%, rotational speeds 200rpm, 300rpm, and operating temperature $80^{\circ}C$. With working fluid amount increasing, overall heat transfer coefficient decreases linearly.

  • PDF

Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat (저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors (물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

Analysis of an Infinitely Long Squeeze Film Damper Operating with an Electro-Rheological Fluid (Electro-Rheological 유체를 이용한 무한폭 스퀴즈 필름 댐퍼 해석)

  • Jeong, Si-Yeong;Choe, Seung-Bok;Jo, Yong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.3
    • /
    • pp.61-66
    • /
    • 1992
  • This paper addresses on the determination of damping coefficients of an infinitely long squeeze film damper operating with an electro-rheological (ER) fluid. The ER fluid behaves as Bingham fluid with an electric field dependent yield shear stress. AS phenomenological model of the fluid is adopted for the relationship between the yield shear and the intensity of the electric field imposed on the fluid domain. The model is then incorporated with the governing equation and associated boundary conditions of the squeeze film damper executing a circula centered orbit for the expression of dimension- less damping coefficients. Numerical simulation is performed to evaluate the performance improvement of the proposed squeeze film damper.

  • PDF

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • v.4 no.3
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.