• Title/Summary/Keyword: Operating Capacity

Search Result 1,197, Processing Time 0.035 seconds

Method for Calculating the Line Capacity Using Computer Aided Simulation (시뮬레이션 기법에 의한 선로용량 산정방법)

  • Choi, Jong-Bin;Lee, Jinsun;Ki, Hyung-Seo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.555-563
    • /
    • 2016
  • Line capacity of railways is a core criterion to decide maximum trips in accordance with traffic demand and a priority in railway investment to improve transportation capability. Particularly, because two operators will start revenue services in the HSR from mid-2016, the line capacity should be carefully calculated and controlled to avoid conflicts between the maximum number of KTXs, and the number needed to guarantee the effective competition of the operators. Meanwhile, there have been many arguments about calculating the line capacity, because this number is affected by the number of trips by train types, stopping pattern and dwell time in each station, journey time, crossing or passing, safety headway between trains, etc. To deal successfully with these kinds of problems, this study proposes a simulation method to calculate the line capacity that considers train operation according to the operator's service policies.

Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter (자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성)

  • Nam, Gueng-Hyun;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Lee, Na-Young;Han, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

A study on performance improvement of position control system in hydraulic cylinder for heavy construction machinery (건설기계용 유압실린더 위치 제어시스템의 성능개선에 관한 연구)

  • 한석재;박성환;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1450-1454
    • /
    • 1996
  • Even though digital control type high speed solenoid valve is a little inferior to analog control type servo valve and proportional control valve in performance, it is cheap and has secure performance against pollutant and simple control circuit. But high speed solenoid valve is hardly used for heavy machinery instead of servo valve or proportional control valve that is used in severe condition because the valve itself is small capacity and it shows wide dead zone during on-off control and chattering of hydraulic cylinder by chattering of pressure. It is desirable to use low-priced and strong pollutant resistant high speed solenoid valve for obtaining reliability of operation from severe working condition because it isn't necessary to acquire response characteristic of high frequency when we consider the characteristic of heavy machinery operation. In this study, PWM control algorithm for pilot pressure control of large capacity pilot operating valve will be used for precision position control of heavy machinery hydraulic cylinder. Not only cost reduction of main control valve but also high reliability of heavy machinery in severe condition can be obtained by using this pilot operating spool valve with high speed solenoid valve.

  • PDF

Performance Characteristics and Economic Assessment of a River Water: Source Heat Pump System (하천수 열원 열펌프 시스템의 성능 특성 및 경제성 평가)

  • Park, Cha-Sik;Jung, Tae-Hun;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.621-628
    • /
    • 2009
  • The objectives of this study are to analyze the performance of a river water-source heat pump and to carry out economic assessment for the heat pump. The COP of the river water-source heat pump was 3-21% higher than that of the air-source heat pump because river water provides stable operating temperature compared with air temperature throughout the year. The economic analysis was carried out by comparing the initial and operating cost of the river water-source heat pump with those of the conventional air-source heat pump. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.5 years when the capacity of the river water-source heat pump was larger than 10 RT.

A Study on Operation Rate and Output of Wave Power Generator by Waves Condition (파랑 조건에 따른 파력발전장치의 가동률과 발전량 산정에 대한 연구)

  • Ryu, Hwang-Jin;Hong, Key-Yong;Shin, Seung-Ho;Kim, Sang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.615-619
    • /
    • 2009
  • This paper is investigated to variation of wave power generation operation rate, operating capacity and output with the wave conditions represented by wave height-period window. By the use of the long-term wave data from 1979 to 2002 which is provided by Korea Ocean Research & Development Institute(KORDI), we calculated the monthly variation of significant wave height(Hs), zero-up crossing period(Tz) and distribution of wave appearance rate. And using the same wave data, it was charted the Hs-Tz and wave-energy scatter diagrams.

  • PDF

Pervaporation of aqueous organic mixture through in situ complex membranes based on polycrylonitrile

  • Lee, Young-Moo;Oh, Boo-Keun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.09a
    • /
    • pp.39-55
    • /
    • 1995
  • Modified polycrylonitrile(PAN) membranes were prepared by emulsion or emulsifier-free emulsion polymerization technique. Separation capacity was determined at several operating temperatures(25, 40, 55 and 70 $^{\circ}$C) to dehydrate 56wt% pyridine aqueous solution through modified PAN membranes having different functional groups. All these PAN-based membranes were selective toward water to different degrees depending on the nature of functional groups present in the membranes. Pervaporation characteristics of PAN-based membranes are so different and classified into three categories depending on the type of the functional groups in PAN copolymers. Among PAN-based membranes, the in-situ complex membranes show the best separation capacity over the operating temperatures.

  • PDF

An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump (가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet (평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기)

  • Cho, J.P.;Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Performance Characteristics of R134a Supercritical Heat Pump (R134a 냉매용 초임계 히트펌프의 성능 특성)

  • Choi, In-Soo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.