• 제목/요약/키워드: Operating Capacity

검색결과 1,190건 처리시간 0.021초

중대형 스크루 압축기의 성능에 관한 연구 (A study of the performance on large capacity screw compressors)

  • 박동성;양승현;이동주;신정관;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

한계이득 측면에서 분석한 발전 예비력 포함 전력거래 (Analysis on Power Transactions of Generation and Operating Reserve Based on Marginal Profits)

  • 신재홍;이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.440-445
    • /
    • 2006
  • As an electricity industry transforms into a competitive system, an electricity market revolves into a combined market consisting of generation and operating reserve. This paper presents a market model combined by an energy market and an operating reserve market. In a competitive structure, Gencos strive to choose strategic bidding parameters that maximize total profit resulting from an energy market and a reserve market. The primary goal of the paper is to analyze power transactions of generation and operation reserve based on marginal profits and capacity limits at NE(Nash Equilibrium). In case studies, the reserve market and the energy market are compared at the n from the viewpoints of marginal profits, prices and transaction quantities. It is shown that the marginal profit in an energy market is equal to that in a reserve market, and Gencos strategic bidding is greatly influenced by capacity limit.

배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석 (Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

Three buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of Three Buffer Pulse Tube Refrigerator)

  • 박성제;고득용;김효봉;신완순
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

태평양 수역 우리나라 다랑어선망어업의 선박 역량에 따른 조업 효율성 분석 (Fishing efficiency by vessel capacity of Korean tuna purse seiners operating in the western and central Pacific Ocean)

  • 이미경;이성일;김두남;구정은;권유정
    • 수산해양기술연구
    • /
    • 제53권2호
    • /
    • pp.169-176
    • /
    • 2017
  • Tuna purse seine fishery in the western and central Pacific Ocean (WCPO) has been rapidly developed since early 1980s due to massive investment of major distant water fishing nations, and catch by purse seine fishery operating in the WCPO accounts for nearly half of the world's tuna total catch. As fishing efficiency is reflected by not only improving of individual vessel's capacity but also increasing number of active vessel, it is essential to understand vessel capacity for reliable assessment result on how fishery affects stock status of target species. In this study, fishing efficiency was analyzed by main factors which are representative of vessel capacity using fishing data and vessel information related to Korean tuna purse seine fishery operating in the western and central Pacific Ocean from 1992 to 2014. It showed that fishing efficiency of vessel tends to be higher when having larger vessel tonnage, higher engine power, lower vessel age and larger length of vessel. As for fishing efficiency by set type, CPUE of associated set with floating objects was generally higher than that of free school set, and CPUE of free school set seemed to have a greater effect on engine power and vessel age compared to other factors.

항로의 교통용량 추정 및 항로 가동률에 대한 고찰 (A Review on the Estimation of Traffic Capacity and Operating Rate of a Fairway)

  • 공인영;양찬수
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2005년도 춘계학술대회 논문집
    • /
    • pp.231-235
    • /
    • 2005
  • 항로의 해상교통량 수용 능력을 평가하는 여러 기법들 중에서, 가장 간단한 수준에서 검토가 가능한 기법으로서, 범퍼 모델을 이용한 항로 교통용량 추정기법에 관하여 기술한다. 항로의 교통용량을 추정하기 위한 간단한 계산식과 실제 항로에서의 교통량을 추정하는 기법에 대하여 고찰하고, 이를 바탕으로 항로의 가동률이라는 개념을 수립하여, 이러한 모델을 우리나라 주요 항만의 진입항로에 적용하여 보았다. 본 기법은, 항로의 기본제원 설계시, 대상 해역에서 예상되는 해상교통량을 그 접근 항로가 수용할 수 있는 능력이 있는지를 검토하기 위한 초기의 정량적 평가 수단으로 사용이 가능할 것으로 판단된다.

  • PDF

무정전 전원장치 효율 향상에 대한 연구 (Efficiency Improvement of Uninterruptible Power Supply Systems)

  • 오홍일;권종원;박용만;오드게럴;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

수소저장합금을 이용하는 수소공급시스템의 운전 방법 최적화 (Operating Strategy Optimization of Metal Hydride based Hydrogen Supply System)

  • 김병준;성해정;이영덕;이상민;조주형;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.625-633
    • /
    • 2011
  • Characteristics of a commercial metal hydride (MH) hydrogen supply system have been investigated and an operating strategy was developed based on the experimental data. As a prior step, charging/discharging capacity, thermal properties such as heat capacity, heat of reaction of MH system were experimentally measured. And then P-C-T data for various operating conditions were collected and a correlation between P, C and T predicting the behavior of MH was derived. Based on the basic experimental data, an operating strategy of MH system was developed, in which the hot water temperature supplied into the water jacket of MH was controlled depending on the pressure of MH, thereby the pressure of MH could be maintained at a suitable range. By adjusting the temperature of hot water from $40^{\circ}C$ to $60^{\circ}C$, the maximum discharging capacity of hydrogen could be increased by 4.7%, and consequently more stable hydrogen supply and longer operation time of fuel cell system could be achieved.

송전선로의 설비특성을 고려한 운영그룹 분류 및 최고허용온도 (An Operation Grouping and Its Maximum Allowable Conductor Temperature Considering Facility-conditions of Transmission Lines)

  • 손홍관;김병걸;박인표;안상현;장태인;최종기
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1922-1928
    • /
    • 2008
  • The thermal rating of a conductor are maximum continuous current capacity and short time emergency current capacity. The overload operation for a faults have an effect on a conductor lifetime. Its time duration and overload level are limited to facility conditions of transmission lines. The short time emergency current capacity in KOREA observe the KEPCO's DESIGN RULE 1210, but its rules are not included to concept of an allowable short time duration. This papers are described to the calculation concept of short time emergency current capacity considering a time duration and an overload level. And we suggested a operation grouping and its maximum conductor temperature considering facility conditions - conductor lifetime, stability of connection points, conductor height above ground and clearance, in the operating and new T/L.