• 제목/요약/키워드: Opening rate

검색결과 704건 처리시간 0.026초

대와류모사를 이용한 연기이동의 연구 II. 제연방식과 개구부의 크기 (A Study on Smoke Movement by Using Large Eddy Simulation II. Smoke Control Systems and Opening Size)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.34-38
    • /
    • 2003
  • The large eddy simulation based Fire Dynamics Simulator was utilized to investigate the effects of the size of an opening on smoke removal performance for the three smoke control systems-ventilation purge, and extraction. Three different opening sizes, $r_A$=1, 2, and 3 were investigated while the flow rate remained 0.75 $m^3/s$ at the inlet or outlet depending on the systems. Increase of the opening size did not give a significant difference in the smoke removal rate for the three smoke control systems, though the increasing opening size slightly improved smoke removal. The extraction system was shown the best smoke control system, and the purge system yielded low performance compared to the other two systems for all the different opening sizes.

Al 2024-T3재의 Crack Opening Point의 평가에 관한 연구 (A Study on Evaluation of Crack Opening Point in Al 2024-T3 Material)

  • 최병기;국중민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.53-58
    • /
    • 2002
  • This paper aims to synthesize the research on fatigue mechanisms of high strength aluminum alloys which are widely used in motorcars or airplanes to prevent accidents. To measure the data of crack opening ratio, the same materials and methods are used for evaluating the fatigue crack propagation rate as an effective stress intensity factor. But, many researchers have brought different results. An exact crack opening ratio was, therefore, proposed for getting a more accurate fatigue crack propagation rate.

  • PDF

Analysis of the Effect of Construction of Public Cremation Facilities in Jeongeup City on Cremators Number Using E-Haneul Funeral Information System in Jeollabukdo and on Cremation Rate

  • Choi, Jae-sil;Kim, Jeong-lae
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.117-124
    • /
    • 2021
  • Based on a result of we research and analysis of this study, it was analyzed that the average annual cremators number using E-Haneul Funeral Information System among the five public cremation facilities in Jeollabukdo was 9,713 in total before the opening of public creation facilities in Jeongeup City (2013-2015), while the number was 12,159 after the opening of public cremation facilities in Jeongeup City (2016-2019); the number was increased by 2,446, compared to the opening period (2013-2015), with a large increase rate of 25.2%. In addition, the average annual cremation rate before the opening of public cremation facilities in Jeongeup City (from 2013 to 2015) was 71.6%, but the average annual cremation rate during the period after the opening (from 2016 to 2019) was 81.5%, which was a large increase rate of 9.9% compared to period before the opening of the facilities. Based on research results above, we have presented policy suggestions in order to increase the efficiency of operation and management of public cremation facilities by local governments as follows. First, in order to prepare for the increase in demand for cremation due to the increase in cremators number, a policy promotion for the expansion of "public cremation facilities" should be carried out as soon as possible, focusing on local governments whose supply has reached the limit. Second, in order to support the expansion and construction of public cremation facilities, the government subsidy rate and government subsidy at the level of current 70%, provided by the central government, should be further expanded. Third, overcoming theNIMBY conflict overlocation for public cremation facilities, theutilization rate should be enhanced, through the joint construction and facility operation of the public cremation facilities between local governments, and the ef iciency of the project implementation should be improved through the jointsharing of the facility operation cost.

설계인자 변경에 따른 버터플라이 밸브 유동 특성에 관한 연구 (CHARACTERISTIC OF BUTTERFLY VALVE FLOW WITH DIFFERENT DESIGN FACTORS)

  • 이종욱;최훈기;유근종
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.170-176
    • /
    • 2009
  • Flow control butterfly valve(FCBV) is known to have difficulty in controlling flow rate along valve opening due to its high flow rate. In low opening condition, the butterfly valve also has some shortcomings such as noise, vibration and erosion which are mostly caused by cavitation effects. Therefore, the FCBV requires proper remedies to reduce cavitation effects and to improve flow control performance. Numerical analysis is applied to FCBV flow to find effects of design factors such as seat diameter and valve opening rate. Cases with 3 different sizes of seat diameter and various valve opening rate are selected for the numerical analysis. From the analysis results, it is found that the FCBV with small seat diameter shows better pressure loss performance and reduced cavitation effects.

  • PDF

설계인자 변경에 따른 버터플라이 밸브 유동 특성에 관한 연구 (CHARACTERISTIC OF BUTTERFLY VALVE FLOW WITH DIFFERENT DESIGN FACTORS)

  • 이종욱;최훈기;유근종
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.64-70
    • /
    • 2010
  • Flow control butterfly valve(FCBV) is known to have difficulty in controlling flow rate along valve opening due to its high flow rate. In low opening condition, the butterfly valve also has some shortcomings such as noise, vibration and erosion which are mostly caused by cavitation effects. Therefore, the FCBV requires proper remedies to reduce cavitation effects and to improve flow control performance. Numerical analysis is applied to FCBV flow to find effects of design factors such as seat diameter and valve opening rate. Cases with 3 different sizes of seat diameter and various valve opening rate are selected for the numerical analysis. From the analysis results, it is found that the FCBV with small seat diameter shows better pressure loss performance and reduced cavitation effects.

모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구 (Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length)

  • 김승재;박종준;김영일
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

모터구동 게이트밸브의 열림행정시 차압 작용에 의한 부하율 연구 (Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke)

  • 김범년;홍성인
    • 한국추진공학회지
    • /
    • 제11권6호
    • /
    • pp.35-41
    • /
    • 2007
  • 부하율은 모터구동 밸브에서 밸브 스템에 가해지는 부하(load) 변화에 따라 구동기 torque와 스템 thrust 사이의 상관관계가 변하는 현상이다. 본 논문에서는 게이트밸브의 열림행정에서 발생되는 부하율 특성을 분석하고 밸브 성능평가시 적용하는 부하율의 타당성에 대해 기술하였다. 또한, 총 40대의 게이트밸브에 대해 정적시험 및 동적시험을 수행하고 본 연구에서 개발한 열림행정에서의 부하율 평가 방법론을 적용하여 각 밸브의 열림행정 부하율을 평가한 결과를 수록하였다. 연구결과로서 열림행정의 부하율은 차압이 150 psi보다 높은 경우 (-)값으로 나타났으며, 이러한 현상은 유체 차압이 높을수록 크게 나타나는 결론을 얻었다.

화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구 (Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant)

  • 강창원;이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제18권3호
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.

Dynamic Analysis of 3 Point Bend Specimens under High Loading Rates

  • Han, Moon-Sik;Cho, Jae-Ung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권2호
    • /
    • pp.84-93
    • /
    • 2000
  • Computer simulations of the mechanical behavior of 3 point bend specimens with a quarter notch under impact load are performed. This validity is found to be identified by the experimental proof. The cases with various loading rates applied at the side of the specimen are considered. An elastoplastic von Mises material model is chosen. Gap opening displacement, reaction force, crack tip opening displacement and strain rate are also compared with rate dependent material(visco-plastic material). The stability during various dynamic load can be seen by using the simulation of this study. These differences of the cases with various loading rates are also investigated.

  • PDF

개구부를 통한 의복의 환기 양상 평가 (Assessment of Clothing Ventilation through Openings)

  • 추미선
    • 복식문화연구
    • /
    • 제8권5호
    • /
    • pp.660-667
    • /
    • 2000
  • Clothing ventilation was investigated using a manikin wearing an impermeable overall under an isothermal condition, in which the ventilation occurred only through the openings. The ventilation volume was estimated by both microenvironment volume and ventilation rate, where, the microenvironment volume was measured by an air subsitution method and the ventilation rate by a trace gas method. Microenvironment volume of the experimental garment was about 21.0 liters. Even though it was certainly affected by the distance from the opening, the ventilation rate was more significantly influenced by the opening area and the shape of air layer in the clothing. The volume of air exchange in the clothing microenvironment was affected greatly by the microenvironment volume and the opening area, and it was different for each part of the body with bigger air exchange volume in the microenvironment of the leg as compared to that of the arm.

  • PDF