• Title/Summary/Keyword: Opening rate

Search Result 707, Processing Time 0.025 seconds

Numerical Study on the Ventilation Effect in the Boiler Building (보일러빌딩 내부 환기현상에 관한 수치적 연구)

  • Kim, Chul Hwan;Yoo, Geun Jong;Choi, Hoon Ki
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.239-249
    • /
    • 2005
  • Ventilation effect is analyzed for boiler building with multiple heat sources. Air flow inside the boiler building is characterized as turbulent mixed convection. Analysis methodology is set up with two different $k-{\varepsilon}$ type models (standard $k-{\varepsilon}$, RNG $k-{\varepsilon}$). Two different cases with high and low outside temperature are analyzed. In case of high outside temperature condition, mixed convection is well realized inside the boiler building. With different upper louver opening rate, air flow is also well established and proper opening rate is found to meet design limit in case of low outside temperature condition. Difference of analysis results for two different turbulence models are not significant. Therefore, analysis methodology with simple $k-{\varepsilon}$ turbulence model is found to be reliable for the boiler building ventilation analysis. However, more simplified geometrical model is desired to expand its application.

A Fundamental Study on Offshore Structures of high pressure control valve (해양구조물용 고압 컨트롤 밸브에 대한 기초 연구)

  • Lee, Chi-Woo;Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.883-888
    • /
    • 2010
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD (Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin (C3H8O3). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve, Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

Characteristics of Bit Error Rate dependence on the Position of Optical Phase Conjugator in 320 Gbps WDM System (320 Gbps WDM 전송 시스템에서 광 위상 공액기의 위치에 따른 비트 에러율 특성)

  • Lee Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1123-1131
    • /
    • 2005
  • In this paper, optimal position of optical phase conjugator (OPC) for best compensating distorted WDM channels due to both chromatic dispersion and self phase modulation (SPM) in $8{\times}40$ Gbps WDM systems is numerically investigated, and the eye opening penalty (EOP) and bit error rate (BER) characteristics of overall WDM channels at this position is investigated, comparing with that in case of OPC placed at mid-way of total transmission length. It is confirmed that the compensation extents in WDM system with OPC is more improved by the shifting OPC position from the mid-way of total transmission length, depending on the modulation format and fiber dispersion coefficient. Ant it is confirmed that, from a viewpoint of the reception performance, EOP of each channel is more or less different with one another, but the BER characteristics of overall channels are almost equal.

Current Status and Reasons for the Location Change of Primary Medical Institutions in Korea (일차의료기관의 이동 현황과 이에 영향을 미치는 요인에 대한 연구)

  • Shin, Soon-Ae;Lee, Jin-Seok;Kim, Chang-Yup;Kim, Yong-Ik;Ha, Beom-Man
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.219-227
    • /
    • 2001
  • Objectives : To understand the current status of the opening, closing and relocation of primary medical institutes in Korea and identify the underlying decision factors. Methods : Sources of analyzed data included the medical institutional master file at the National Health Insurance Corporation(1998, 2000) and Regional Statistic Annual Bulletins. To investigate changes including the opening, closing and relocation, a total of primary medicalinstitutions(16,757 in 1998, 19,267 in 2000) were analysed. Results : Between 1998 and 2000, there was a 15.0%(2,510) increase in the number of primary medical institutions and the rate of increase in the rural area was higher than the urban area, and higher for specialty clinics than primary practice. However, these findings did not suggestany improvement in the maldistribution of primary medical institutions. During the time period studied, newly opened and closed primary medical institutions numbered 4,085 and 1,573, respectively. Additionally, institutions thatrelocated numbered 2,729, or 16.3% of all primary medical institutions in operation in 1998. These openings and closings were more frequent among young doctors. As a result of our analysis on the underlying regional factors forrelocation, the factors that were statistically significant were local per capita tax burden and the number of schools per ten thousand persons. !n, the case of institutional factors, movements were significantly associated with gender and the location of primary medical institutions. Conclusions : In order to establish effective long-term intervention for primary medical institutions, further study and monitoring of primary medical institutions and the identification of factors influencing opening location and relocation is necessary.

  • PDF

Effects of the Geometry and Location of an Vertical Opening on the Fire Characteristics in the Under-Ventilated Compartment Fire (환기부족 구획화재에서 수직 개구부의 형상 및 위치가 화재특성에 미치는 영향)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.20-29
    • /
    • 2013
  • To investigate numerically the effects of geometry and location of vertical opening on the thermal and chemical fire characteristics in full-scale under-ventilated compartment fires, the ventilation factor ($A\sqrt{h}$) to estimate a theoretical maximum inflow of ambient air and the mass loss rate in a heptane pool fire were fixed for all cases. It was shown that variations in door geometry affected significantly the change in thermal and chemical characteristics inside the compartment. Variations in window location resulted in the complex change in additional fire characteristics including the fire duration time and recirculating flow structure. These results were analyzed in details by the multi-dimensional flow and fire characteristics including the vent flow and fuel/air mixing phenomena.

Interaction between opening space in concrete slab and non-persistent joint under uniaxial compression using experimental test and numerical simulation

  • Vahab Sarfarazi;Kaveh Asgari;Mehdi Kargozari;Pouyan Ebneabbasi
    • Computers and Concrete
    • /
    • v.31 no.3
    • /
    • pp.207-221
    • /
    • 2023
  • In this investigation, the interaction between opening space and neighboring joint has been examined by experimental test and Particle flow code in two dimension (PFC2D) simulation. Since, firs of all PFC was calibrated using Brazilian experimental test and uniaxial compression test. Secondly, diverse configurations of opening and neighboring joint were provided and tested by uniaxial test. 12 rectangular sample with dimension of 10 cm*10 cm was prepared from gypsum mixture. One quarter of tunnel and one and or two joint were drilled into the sample. Tunnel diameter was 5.5 cm. The angularities of joint in physical test were 0°, 45° and 90°. The angularities of joint in numerical simulation were 0°, 30°, 60°, -30°, -45°, -60° and its length were 2cm and 4cm. Loading rate was 0.016 m/s. Tensile strength of material was 4.5 MPa. Results shows that dominant type of crack which took place in the model was tensile cracks and or several shear bands develop within the model. The Final stress is minimum in the cases where oriented angle is negative. The failure stress decrease by decreasing the joint angle from 30° to 60°. In addition, the failure stress decrease by incrementing the joint angle from -30° to -60°. The failure stress was incremented by decreasing the number of notches. The failure stress was incremented by decreasing the joint length. The failure stress was incremented by decreasing the number of notches. Comparing experimental results and numerical one, showed that the failure stress is approximately identical in both conditions.

Analysis on Short Crack Growth Rate after Single Overload under Cyclic Bending Moment

  • Song, Sam-Hong;Lee, Kyeong-Ro;Kim, Amkee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.19-26
    • /
    • 2001
  • In order to investigate the effect of single tensile overload on the short crack growth behavior under the out-of-plane cyclic bending moment, crack opening stresses were continuously measured by an elastic compliance method using strain gages. The characteristics of short crack growth after the single tensile overload are analyzed by the effective stress range ratio. Futhermore, the investigation was carried out with respect to various fatigue crack growth behaviors such as the plastic zone size effect on crack retardation, the retarded crack length and the number of cycles.

  • PDF

Study of the Fluid Flow on Proportional Valve in Spool Displacement using CFD

  • Li, Kui-Ming;Choi, Yoon-Hwan;Lee, Ill-Yeong;Lee, Yeon-Won
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.22-26
    • /
    • 2015
  • The main objective of this work is to estimate the fluid flow of a proportional valve. The study is based on the classical compressible flow theory and the computations with the help of CFD based commercial software - ANSYS CFX. The fluid flow with the movement of spool along the sleeve is simulated. To change the spool moving from 0.4mm to 2.0mm, the moving mesh method with different condition of orifice is considered here. The results show that it is the highest at the 80 % (1.6mm) opening and at the 20 % (0.4mm) opening, is the lowest.

Study on Flow Characteristics for Eccentric Shaft in the Butterfly Valve System (축편심 버터플라이 밸브의 유동특성에 관한 연구)

  • Park, S.M.;Choi, H.K.;Yoo, G.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.587-591
    • /
    • 2011
  • To improve the performance of the control butterfly valve seals are used to eccentric shaft. In this case, vertical opening gas of the butterfly valve is non-symmetrical, which will change the flow pattern around the valve. In this study, the eccentric drive shaft of the butterfly valve to change flow characteristics are performed numerically. Flow pattern and pressure drop are investigated as the valve opening angle increases for a given mass flow rate. The valve flow coefficient is compared to the without eccentric shaft.

  • PDF

Gradual Scene Change Detection Using Variance of Edge Image (에지 영상의 분산을 이용한 비디오의 점진적 장면전환 검출)

  • Ryoo, Han-Jin;Yoo, Hun-Woo;Jang, Dong-Sik;Kim, Mun-Hwa
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.3
    • /
    • pp.275-280
    • /
    • 2002
  • A new algorithm for gradual scene change detection in MPEG based frame sequences is proposed in this paper. The proposed algorithm is based on the fact that most of gradual curves can be characterized by variance distributions of edge information in the frame sequences. Average edge frame sequences are obtained by performing "sober" edge detection. Features are extracted by comparing variances with those of local blocks in the average edge frames. Those features are further processed by the opening operation to obtain smoothing variance curves. The lowest variance in the local frame sequences is chosen as a gradual detection point. Experimental results show that the proposed method provides 85% precision and 86% recall rate fur gradual scene changes.