• Title/Summary/Keyword: Opening location

Search Result 262, Processing Time 0.025 seconds

Effects of openings geometry and relative area on seismic performance of steel shear walls

  • Massumi, Ali;Karimi, Nasibeh;Ahmadi, Mostafa
    • Steel and Composite Structures
    • /
    • v.28 no.5
    • /
    • pp.617-628
    • /
    • 2018
  • Steel shear wall possesses priority over many of the current lateral load-bearing systems due to reasons like higher elastic stiffness, desirable ductility and energy absorption, convenience in construction and implementation technology, and economic criteria. Besides these advantages, this system causes increase in the dimensions of other structural elements due to its high stiffness as one of its intrinsic characteristics. One of the methods for stiffness reduction is perforating the wall panel and creating openings in the wall that can also be used as windows or ducts in buildings service period. The aim of the present study is probing the appropriate geometric shape and location of opening to fulfil economic criterion plus technical and seismic design criteria. In the present research, a number of possible while reasonable opening shapes and locations are defined in various sizes for some steel shear wall specimens. The specimens are modelled in ABAQUS finite elements software and analyzed using nonlinear pushover analysis. Finally, the analyses' results are reported as force-displacement diagrams and the strength, the initial stiffness and the energy absorption are calculated for all specimens and compared together. The obtained results show that both shape and location of the openings affect the seismic parameters of the shear wall. The specimens in which the openings are further from the center and closer to the columns possess higher stiffness and strength while the specimens in which the openings are closer to the center show more considerable changes in their seismic parameters in response to increase in opening area.

A Study on Opening of Commercially Available Nursing-wear (시판 수유복의 트임에 관한 연구)

  • Lee, Jung-Jin;Lee, Jung-Soon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.1
    • /
    • pp.93-104
    • /
    • 2015
  • As interest grows in nursing-wear in accordance with dissemination of breast-feeding, a study on opening of nursing-wear is needed to enhance convenience of breast-feeding regardless of location. In this study, the items on nursing-wear were classified and each characteristic was analyzed. The types and characteristics of opening on nursing-wear were identified and the characteristics of nursing brassier closely related to the nursing-wear were also identified. Top 5 companies for the nursing-wear and nursing-brassier were selected by ranking top 5 in NAVER with the search word 'nursing-wear' and 'nursing-brassier'. 732 one-piece and top (t-shirt and blouse) which have the highest portion in the nursing-wear were selected as the subject. Based on the photo, product explanation on the internet and in-depth interview of designer, the types and characteristics of openings for each item were identified. 732 nursing-brassier were selected to study the types and openings in breast-feeding. The result is as follows. Firstly, the item of nursing-wear can be classified into top, one-piece, package of top and the bottom, and sleeveless. Top and one-piece have the highest production rate. Secondly, the types of the openings are either covering or opening types. There are vertical-slit and horizontal-slit in covering type, and vertical-zipper, horizontal-zipper, and button types in opening type, and overlap and pocket type for the rest. Thirdly, the commercially available nursing-brassier according to the opening manner can be classified into upper-opening, middle-opening, and overlap types. Most largely produced product is upper-opening type as it minimizes the exposure of the breast in breast-feeding. When producing the nursing-brassier, the measurement of the lower breast and cup size are considered.

  • PDF

Effects of Initial Condition and Opening Geometry of a Compartment on the Gravity Current in the Backdraft (백드래프트의 중력흐름에 미치는 구획실 내부 초기조건 및 개구부 형상의 영향)

  • Park, Ji-Woong;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.18-25
    • /
    • 2015
  • Computational study of a gravity current prior to the backdraft was conducted using fire dynamic simulator (FDS). Various initial conditions of mixture compositions and compartment temperature as well as four opening geometries (Horizontal, Door, Vertical, and Full opening) were considered to figure out their effects on the gravity current. The density difference ratio (${\beta}$) between inside and outside of compartment, the gravity current time ($t_{grav}$) and velocity ($v_{grav}$), and non-dimensional velocity ($v^*$) were introduced to quantify the flow characteristics of the gravity current. Overall fluid structure of the gravity current at the fixed opening geometry showed similar development process for different ${\beta}$ conditions. However, $t_{grav}$ for entering air to reach the opposed wall to the opening geometry increased with ${\beta}$. Door, Vertical, and Horizontal openings where openings are attached on the ground showed similar development process of the gravity current except for Horizontal opening, which located on the middle of the opening wall. The magnitude of $v_{grav}$ at fixed ${\beta}$ was, from largest to smallest, Full > Vertical > Door > Horizontal, but it depended on both the size and location of the opening. On the other hand, $v^*$ was found to be independent to ${\beta}$, and only depended on the geometry of the opening.

A Vibration Isolation Design for Engine Room Opening Deck around Heavy Spare Parts of the Main Engine (Main Engine의 Heavy Spare Parts가 설치된 Engine Room Opening Deck의 방진 설계 사례)

  • Jeon, Yong-Hoon;Lim, Gu-Sub;Jeong, Tae-Seok
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.93-96
    • /
    • 2009
  • Foundation structure for the main engine heavy spare parts in the engine room is susceptible to resonance problem due to outfitting weight. In addition the deck floor has a large opening for the main engine installation and maintenance, which further weakens the foundation structure. To reinforce the weak structure, two types of approaches have been used; 1) insert an H-pillar below or above the floor and 2) increase the stiffener size. In this paper, the H-pillar approach is used to solve the vibration problem of the foundation structure in the engine room opening area. A commercial program is used to analyze the vibration problem ad to find the location and the size of the H-pillar. Modal test at the quay and on-board vibration measurement during the sea trial have confirmed the validity of inserting an H-pillar below the floor.

  • PDF

Investigation into the behaviour of deep beam with web openings by finite element

  • Doh, Jeung-Hwan;Yoo, Tae-Min;Miller, Dane;Guan, Hong;Fragomeni, Sam
    • Computers and Concrete
    • /
    • v.10 no.6
    • /
    • pp.609-630
    • /
    • 2012
  • Currently, the design of reinforced concrete deep beams with web openings is carried out using empirical or semi-empirical methods and hence their scope of application is limited. In particular, high strength concrete deep beams with various web opening configurations have been given little treatment. In view of this, a nonlinear layered finite element method (LFEM) for cracking and failure analysis of reinforced concrete structures is used to conduct a parametric study to investigate reinforced concrete deep beams various web opening behaviours. This paper initially presents comparisons of LFEM output with published test results to numerical techniques. The paper then focuses on a parametric study on the shear strengths of deep beams with varying web opening configurations such as opening sizes and locations. The results confirm that the current design methods are inadequate in predicting the maximum shear strength when web openings are present. A series of parametric study offers insight into the maximum shear strength of the deep beams being critically influenced by the size and location of web openings.

A Study on the Structural Properties of RC Beams with Web Openings using Square Steel Tube (각형강관을 이용한 RC 유공보의 구조 특성 연구)

  • Lee, Seung-Jo;Park, Jung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.85-86
    • /
    • 2010
  • This study is aimed to investigate on the structural properties (like as strength, failure mode, ductility) of beams with web openings reinforced with steel tube of square. The main parameters are follows; 1) with and without web opening 2) the number of opening, 3) location of openings. In the quasi-static tests, structural properties of PFBS1A and PFBS2A were most superior. When the locations of opening are respectively maximal moment zone (M), shear (S), co-existence area of moment and shear (M+S), the specimen with web opening at maximal moment zone is not less than that without web opening in terms of strength and ductility.

  • PDF

A Study on the Buckling Strength of Plate Panels with Opening (유공판의 좌굴강도에 관한 연구)

  • Kim, Ul-Nyeon;Choe, Ick-Heung;Kwon, Jin-Chil;Paik, Jeom-Kee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.210-224
    • /
    • 2010
  • The aim of the present study is to investigate the buckling strength of plates and stiffened panels with opening under transverse thrust and shear actions. It is observed that the existing design formulation for critical-buckling strength of plates are not valid for perforated plates, because the current design formulation trends can significantly overestimate or underestimate the load-carrying capacity of plates when plates have large opening and/or are thick. A series of eigen value and elastic.plastic large deflection finite element analyses are carried out with varying the aspect ratio of plate, the opening size and location on plate until and after the ultimate strength is reached. Based on the results obtained from the present study, closed-form design formulations for the elastic buckling strength of plates and stiffened panels with opening are derived. The derived design formulations are considered plasticity correction of the material and verified by experimental tests and results of nonlinear finite element computations.

An Experimental Study on the Web Reinforcement Effects of Reinforced Concrete Deep Beams with Web Opening (개구부를 갖는 깊은 보의 보강근 효과에 관한 실험적 연구)

  • 이경미;이진섭;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.519-524
    • /
    • 1998
  • The shear behavior and reinforcement effects of simply supported reinforced concrete deep beams with web opening subject to concentrated loads have been scrutinized experimentally to verify the effects of structural parameters such as size, location and reinforcements of web opening. A total of 14 specimens were tested at the laboratory under two-point top loading. The shear span ratio was taken constantly 0.8, and various types of reinforcements based on truss models were adopted. In the tests, the effects of loction, reinforcements of web openings on the shear behavior, and crack initiation and propagation have been carefully checked and analyzed.

  • PDF

Flow rate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure (Segmental Wedge를 이용한 차압식 유량측정 방법)

  • Yoon J.Y.;Sung N.W.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.22-28
    • /
    • 2006
  • The discharge coefficient in segmental wedge haying ninety degrees yeller angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured. Main purpose of this work is placed on specifying the characteristic of discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and suggestion for the fixed location of pressure taps useful. Although the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated. The Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000.

Aerodynamic Methods for Mitigating the Wind-Induced Motions on the Tall Buildings (고층건축물의 풍진동 저감을 위한 공기역학적 방법)

  • Ha Young-Cheol;Kim Dong-Woo
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.431-434
    • /
    • 2002
  • The excessive wind-induced motion of tall buildings most frequently result from vortex shedding induced across-wind oscillations. This form of excitation is most pronounced far relatively flexible, lightweight and lightly damped structure, e.g. tall building. This paper discusses aerodynamic means for mitigating the across-wind vortex shedding induced in such situations. Emphasis is on the change of the building cross section to design the building with openings from side to side which provide pressure equalization and tend to reduced the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. Wind tunnel test have been carried out on the Kumoh National University of Technology using rigid models with twenty-four kinds of opening shapes. Form these results, the effective opening shape, size and location for building to reducing wind-induced vortex shedding and responses are pointed out.

  • PDF