• Title/Summary/Keyword: Opening height

Search Result 215, Processing Time 0.024 seconds

The opening efficiency of the miniaturized large-scale net for anchovy boat seine to reduce the fleet size (선단 축소를 위한 기선권현망 축소형 대형 어구의 전개 성능)

  • AN, Young-Su;BACK, Young-Su;JIN, Song-Han;JANG, Choong-Sik;KANG, Myoung-Hee;CHA, Bong-Jin;CHO, Youn-Hyoung;KIM, Bo-Yeon;CHA, Ju-Hyeng
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.12-24
    • /
    • 2018
  • This study was conducted in order to improve opening efficiency of the miniaturized large-scale net for anchovy boat seine gear to reduce the fleet size. Field experiments were performed to observe geometry of nets by catcher boats. When the distances between the two ships were 150, 300 and 450 m, and the speeds of towing nets were 0.6, 0.9, and 1.2 k't, respectively. The vertical opening and actual opening of each part of the miniaturized large-scale net was as follows: the front part of the wing net, 8.7-13.3 m, 51-78%; the middle part of the wing net, 28.1-34.2 m, 55-67%; the entrance of the inside wing net, 31.3-38.5 m, 60-73%; the square and bosom, 22.7-29.6 m, 47-62%; the entrance of the body net, 20.9-26.4 m, 42-52%; the entrance of the bag net, 17.2-21 m, 72-89%; the flapper, 13.2-15.3 m, 78-83%; and the end of the bag net, 13.2-15.7 m, 72-75%. By connecting the net pendants with the front part of the wing net, the opening of the front part of the wing net was significantly improved compared to the traditional gear, which ensured both the wing net and the inside wing net with a normal net height. This, in turn, increased the efficiency of herding. The height of the body and bag nets was also higher than that of the tradition gear. In particular, the body net attached to the gear significantly improved the pocket shape of the gear and reduced the number of fish that were caught and escaped from the bag net, which increased the rate of fishing. The tension of towing nets was measured approximately between 2,958 and 7,110 kg, which indicates that the fleet can tow nets with 350 ps, the standard engine horse power. The fishing operation time was shortened compared with of the existent net, and the large-scale buoy attachment operation was also possible to operate the ship without fish detecting boat.

A study on the crack initiation of SCM 4 (SCM4 의 크랙開始点 에 관한 硏究)

  • 옹장우;박찬국;김재훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.135-139
    • /
    • 1985
  • A J$_{IC}$ test procedure by ultrasonic method performed to observe the crack opening behavior of fatigue precrack and detect the initiation of crack propagation of compact tension specimen in this paper. Pulse-echo method with 5 MHz transducer was used on the Cr-Mo steel quenched and tempered at 593.deg. C. We obtained the following results in the elastic-plastic fracture toughness test by ultrasonic method. Echo height is a little increased linearly and rapidly at the early stage of loading . Then it is decreased considerably, finally at the unstable crack growth stage, it is rapidly increased at an unpredictable rae. The initiation of crack propagation is supposed to be at the stage deviated from linearly decreased region and then blunted. J$_{IC}$ value(10.15-12.15 Kgf/mm) by ultrasonic method is lower than that(12.2 Kgf/mm) by R-curve method. But, it is required that the research for the more exact evaluation about correlation between echo height and the crack opening behavior of precrack tip will be continued. continued.ued.

Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside - (배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 -)

  • Lee , Seong-Haeng;Woo , Sang-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

Stack Effect Mitigation Methods in Exit Route of High-rise Building (고층 건축물 피난경로의 연돌효과 저감 방안)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.284-288
    • /
    • 2010
  • Length of staircase get longer and evacuation load get heavier in proportion to the building height. Therefore evacuation time could be considered proportional to square of building height. While smoke spreads vertically so rapidly, evacuation speed is too slow, therefore the reasonable measure for the safe of egress route is urgent. Existing pressurizing smoke control system of vertical exit route is seriously limited in function under the stack effect in winter. Stack effect in winter could be overcome with the methods of opening the staircase outward or letting airflow be free between staircase and outside.

  • PDF

Experimental Study of Coupled Shearwalls with different Coupling Member (인방보의 형태에 따른 개구부가 있는 전단벽의 거동 특성에 대한 실험적 연구)

  • Bae, Baek-Il;Choi, Hyun-Ki;Choi, Yoon-Chel;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.37-40
    • /
    • 2008
  • Many engineers find the way of improving the old building's structural behavior in the remodeling project which is performed using artificial openings for merging two houses. This test was performed to verify the characteristics of coupling beams according to the shape of the openings. One of test specimen has rectangle shape and the other was made by the circle shaped opening and one has coupling member only as slabs. Additionally, three specimens which have openings have 23% ratio in opening area to total wall area. Consequently, solid type which have no opening area shows shear failure. In the case of CW-RBS which have rectangular shaped opening, cracks are developed in coupling beam significantly. And CW-CS which has circular opening failed in shear showing development of diagonal cracks at wall toes and wall mid-height. It is thought that degradation of the wall strength is under the control of the opening shape and coupling beam-wall connection area.

  • PDF

Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites (대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.464-472
    • /
    • 2014
  • In large-opening room-and-pillar mining sites, particularly without the devices for the ventilation control, the airflow pattern created by the local fan operation is too complicated to quantify and also shows low ventilation efficiency. This study aims at performing a series of CFD analysis for the so-called venturi effects of the local fans; the effects of increasing airflow rate along the axis downstream of fan resulting from increased kinetic energy and subsequently decreased static pressure in the downstream. Effects of the fan type and installation height are compared. 1 vane-axial fan and 2 propeller fans are analyzed for their venturi effects, while the vane-axial fan was installed at the height of 1.0, 1.5 and 2.0m for comparison. The results can be applied to improve the economy and efficiency of local fans for securing better air quality and work environment management.

Finite Element Analysis of Silo Type Underground Opening for LILW Disposal Facility (사일로 구조형식 중저준위 방폐물 처분동굴의 유한요소 해석)

  • Kim, Sun-Hoon;Kim, Kwang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.339-345
    • /
    • 2021
  • Finite element analysis of the silo type underground opening for low- and intermediate-level radioactive waste (LILW) disposal facilities in Korea is presented in this study. The silo wall is circular and the roof is made up of domes. The silo wall is 25 meters in diameter, 35 meters in height, and the dome is 30 meters in diameter and 17.4 meters in height, and it is located at -80 meters to -130 meters at sea level. Although six silos have been constructed in the first stage and are in operation, only one silo was considered in this study. The two-dimensional axial symmetric finite element model, as well as the three-dimensional finite element model were made using the computer program SMAP-3D. Generalized Hoek and Brown Model was used for the numerical analyses. The finite element analysis of the silo type underground opening was carried out under various lateral pressure coefficients (defined as ratio of average horizontal to vertical in-situ stress), and the numerical results of these analyses were examined.

Dynamic Characteristic of Truss Type Lift Gate by Model Tests (모형실험에 의한 트러스형 리프트 게이트의 진동 특성)

  • Lee, Seong Haeng;Shin, Dong Wook;Kim, Kyoung Nam;Jung, Kyoung Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.337-345
    • /
    • 2012
  • A model test is performed to investigate the dynamic behavior of truss type lift gate which is being constructed by the four major rivers project. The gate dimensioned 40 m in width, 9m in height is scaled with the ratio of 1:25 and is made of acryl panel and supplemented weight by lead in the concrete test flume dimensioned 1.2 m in width, 0.5 m in height and 30m in length. Firstly natural frequencies of the model gate are measured and compared with the numerical results for the calibration. The amplitudes of the vibration are measured under the different gate opening, upstream water level conditions. Also models with bottom angle $20^{\circ}$, $35^{\circ}$ and $50^{\circ}$ are tested and compared to find out a proper shape of bottom structure which minimizes the gate vibration. These test results presents a basic data for the guide manuals of gate management and a design method to reduce the gate vibration of truss type lift gate.

Effect of a through-building gap on wind-induced loading and dynamic responses of a tall building

  • To, Alex P.;Lam, K.M.;Wong, S.Y.;Xie, Z.N.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.531-553
    • /
    • 2012
  • Many tall buildings possess through-building gaps at middle levels of the building elevation. Some of these floors are used as sky gardens, or refuge floors, through which wind can flow with limited blockage. It has been reported in the literature that through-building gaps can be effective in reducing across-wind excitation of tall buildings. This paper systematically examines the effectiveness of two configurations of a through-building gap, at the mid-height of a tall building, in reducing the wind-induced dynamic responses of the building. The two configurations differ in the pattern of through-building opening on the gap floor, one with opening through the central portion of the floor and the other with opening on the perimeter of the floor around a central core. Wind forces and moments on the building models were measured with a high-frequency force balance from which dynamic building responses were computed. The results show that both configurations of a through-building gap are effective in reducing the across-wind excitation with the one with opening around the perimeter of the floor being significantly more effective. Wind pressures were measured on the building faces with electronic pressure scanners to help understand the generation of wind excitation loading. The data suggest that the through-building gap reduces the fluctuating across-wind forces through a disturbance of the coherence and phase-alignment of vortex excitation.

Proposal of the Unsupported Span of Openings in the Domestic Underground Limestone Mines (국내 지하 석회석광산 갱도의 무지보 폭을 위한 제안)

  • SUNWOO, Choon
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.358-371
    • /
    • 2018
  • The stability of openings in the underground mine is major concern in the operation of mines that must ensure productivity and safety. Among many rock conditions affecting cavities stability, the width and height of the opening is an important design factor. In this paper, we consider to determine the maximum unsupported span of a opening in a limestone mine by using the Q system among several rock classification schemes. In order to determine the span of the unsupported opening in the limestone mine, rock mass classifications were carried out at over 200 sites in the underground limestone mines. The relationships by using the Q system and the stability graph proposed by Mathews to determine the maximum span of the unsupported opening were derived and compared. We propose a new classification method that combines GSI and RMR rock classification systems to make it easy to use in a field.