• 제목/요약/키워드: Opening height

검색결과 215건 처리시간 0.029초

바람소리 저감을 위한 선루프 디플렉터 주위의 유동에 관한 연구 (Study of Flow Characteristics behind a Sunroof Wind Deflector for Wind Noise Reduction)

  • 이덕영;윤정환;신재혁;김상곤
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.182-189
    • /
    • 2009
  • The noise from the sunroof can be divided into the low frequency buffeting noise and the high frequency turbulence noise generated when a car runs at the high driving speed. The wind deflector suppresses the buffeting noise generation by accelerating the vortex shedding from the front edge of sunroof opening, and guides the flow direction so that air can pass smoothly over the sunroof opening. To reduce the buffeting noise and the high frequency noise, it is very important to locate a deflector in a proper position depending on the driving speed and the sunroof opening width. The deflector's sectional shape also plays an important role in efficiently reducing the buffeting and high frequency noise. In this paper, we determined the optimum deflector's sectional shape and examined the flow characteristics behind a sunroof deflector through CFD analysis with changing the deflector height, the driving speed and the sunroof opening width. It is found that the deflector needs to be located in the higher location to control the buffeting noise by shedding the higher frequency vortices to accelerating vortices from the sunroof front edge. The deflector may act as a new noise source at the high driving speed, then it is desirable to put the deflector at the proper height to reduce the flow fluctuations and the noise generation. We also made a road test to verify CFD analysis results in this study.

개구부에 삽입한 수직평판이 헬륨.공기치환류에 미치는 영향 (Effect of Partition within Opening on Helium-Air Exchange Flow)

  • Tae-il Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.797-805
    • /
    • 2003
  • This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratios H_p/H$_1$$ in the range 0 to 1. where H_p$ and H$_1$ are partition length and height of the opening. respectively. In the case of H_p/H$_1$$ of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated (bidirectional), and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore, the exchange flow rate is minimum through range of the partition ratios. Two flow zones, i.e., separated (unidirectional) flow zone and unseparated (bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at H_p/H$_1$$ of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

역타기둥 이음부의 공기포 배출을 위한 실험적 연구 (The Experimental Study on Deflation of Air for Top-Down Joint area)

  • 임형일;이동하;백민수;박병근;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.763-768
    • /
    • 2001
  • The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method. The result of study is below (1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in joint column. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.

  • PDF

전산화 단층 촬영법을 이용한 하악과두의 위치에 관한 연구 (A STUDY ON THE POSITION OF CONDYLAR HEAD ON COMPUTED TOMOGRAM)

  • 이종복;김재덕
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.151-162
    • /
    • 1987
  • The author obtained the computed tomograms around the condylar head from 10 normal subjects and 5 patients having clicking condylar head from 10 normal subjects and 5 patients having clicking sound or limitation of mouth opening by using a Hitachi-W 500. And then. the author had the axial analysis of condyle position and sagittal analysis of that after sagittal reformation on centric occlusion and 18㎜ interincisal opening. Transcranial view and submentovertex view were taken and compared with computed tomographic view. The obtained results were as follows: 1. Median angle of long axis of condylar head was 17 degrees on centric occlusion and the angles of long axis of both condylar heads were reduced symmetrically on 18㎜ interincisal opening in normal group. however. in the patient group, the affected side of condyle heads showed greater change in the angle on 18㎜ interincisal opening. 2. In the patient group, the condyle head of affected side was located superiorly to that of normal side on centric occlusion and the discrepancy of condular positional height was increased after 18㎜ interincisal opening. 3. The distances from medial pole of condylar head to triangular fossa of temporal bone were same on both right and left side in normal group, however, in the patient group, the distance of affected side was wider than that of opposite side on centric occusion and became narrower than the opposite side on 18㎜ interincisal opening. 4. The distances of posterior joint space were same on both right and left side. The distance t lateral pole 1/3 of condyle head was similar to that on transcranial view on centric occlusion in normal group. 5. The distances of posterior joint space were narrower in patient group than in normal group. 6. Conclusively, the affected condylar head of patient showed postero-latero-superior displacement on centric occlusion and larger range of rotational movement on 18㎜ interincisal opening.

  • PDF

건물화재시 개구부의 흐름계수에 관한 연구 (A Study on the Flow Coefficient of Compartment Fire)

  • 허만성
    • 한국화재소방학회논문지
    • /
    • 제10권4호
    • /
    • pp.19-27
    • /
    • 1996
  • 상층부의 온도, 경계면 높이 및 흐름형태를 연구하기 위하여 쓰레기통, 의자, 카페트, 소파, 매트리스 및 장농화재 실험을 실제 건물에서 수행하였다. 상부층의 온도와 경계면의 높이는 사각 쓰레기통의 경우 개구부의 흐름계수가 0.65∼0.8, 원형 쓰레기통 및 의자의 경우는 0.65∼0.9, 카페트, 소파, 매트리스 및 장농의 경우는 0.7∼O.9일 때 실험치와 비교적 잘 일치하였다. 경계면의 높이는 가구화재시 1[m] 근처에서 정상상태를 유지하였다. 다만, 최대온도를 나타내는 시간에는 경계면 높이가 바닥에서 0.25[m]∼0.75[m]까지도 내려왔다. 개구부의 흐름형태는 분산화재의 경우는 filling과 buoyant흐름이 나타났고, 집중화재의 경우는 filling에서 바로 flow로 가고 또 flow기간도 길게 나타났다. 경계면 높이가 내려오는 속도는 가구의 가연성 및 공기와의 접촉면적에 비례하여 경계면 높이가 1[m] 근처까지 내려오는데 소요되는 시간은 1분∼3분 이내로 나타났다.

  • PDF

토션바 트렁크의 팝업량 산포 분석을 위한 해석모델 (Analytical Model for the Analysis of Pop-up Deviation of the Trunk Lid with Torsion Bar)

  • 손성민;윤재득;정융호;임향수;장국진
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.175-181
    • /
    • 2014
  • A four-link mechanism consisting of torsion bars is used for opening the trunk lid in most midsize sedans. When the weight of the lid is in equilibrium with the spring force exerted by torsion bars, the lid stops opening at a pop-up height. However, the actual pop-up height has large deviations from the specified height even with the same parts in the same car model, which leads to quality issues. Automotive manufacturers have experienced this deviation problem despite much effort to resolve it. In this research, we developed a multi-body dynamics model for the analysis of pop-up deviation of a trunk lid with torsion bars, which can simulate the actual pop-up motion of the trunk lid by considering kinematic constraints of the motion and friction forces in joints. We could also determine the most important factor that governs the pop-up height by sensitivity analysis of all parts. The developed system can be used for the analysis of other trunk lid systems to control the tolerance of parts.

External photoglottography, intra-oral air pressure, airflow and acoustic data on the Korean fricatives /s', s/

  • Kim, Hyunsoon;Maeda, Shinji;Honda, Kiyoshi;Crevier-Buchman, Lise
    • 말소리와 음성과학
    • /
    • 제14권3호
    • /
    • pp.11-25
    • /
    • 2022
  • From simultaneous recordings of the external photoglottography, intra-oral air pressure (Pio), airflow and acoustic data from four native Seoul Korean speakers (2 male and 2 female), we have found that the two fricatives are not significantly different in glottal opening peak and airflow peak height either word-initially or word-medially and that the duration of aspiration is significantly reduced in word-medial /s/, compared to those in word-initial /s/, not in /s'/. We have also found that the duration of a high Pio plateau is significantly longer in /s/ than in /s'/ both word-initially and word-medially and that airflow resistance (R=Pio/U) at the onset and offset of a Pio plateau and at the time of airflow peak height is significantly higher in /s'/ than in /s/ across the contexts. However, the differences in Pio peak and F0 are not significant. In addition, the transition time to reach airflow peak height from the offset of a Pio plateau is found to be significantly longer in /s/ than /s'/ in both word-initial and word-medial positions. No significant differences in glottal opening peak and airflow peak height confirm that /s/ is specified as [-spread glottis] like /s'/. As for the other significant differences, we propose that /s/ is [-tense], and /s'/ [+tense].

철근콘크리트 유공보에 관한 연구 (A Study on Reinforced Concrete Beams with Perforation)

  • 박경호
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.7-14
    • /
    • 2001
  • In building structure, the story height can be minimized by providing openings in beams which serves for the utility equipments passing through. The dead space in false ceiling thus put to economical use in the form of a substantial reduction in materials and construction cost. In the case of steel structure, there is no critical risk in the structural strength because of reinforcing methods of stiffness and steel plate but in the case of reinforced concrete structure, proper provision should be made in designing these openings, otherwise there is a risk that these opening will possibly weaken the structural strength of the building frame to a critical degree. In this paper, for the numerical analysis of the reinforced concrete beams with circular opening in the web, expecting stress concentration of the circular opening, reinforcing methods were studied. Twenty test pieces with each different reinforcing methods were tested and their resisting forces were defined. From the numerical analysis and test results, the followings were founded;(1)high shear stress distributed around the openings reduce the shearing strength, (2)from the numerical analysis, the maximum tensile stress occurred at opening nodes 1,7, these phenomena were agreed with the test results, (3)reinforcing method around openings have to carried out for stopping diagonal cracks, and (4)both, by steel plate, and wire mesh, are effective reinforcing methods.

  • PDF

쉘타입 로울러 게이트의 회피개도량 산정 방법 (A Method on Estimation of Avoiding Open Range on Shell-type Roller Gate)

  • 정지승;정해욱
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.85-91
    • /
    • 2017
  • When the shell-type roller gate is partly open, at a certain height the large vibration is caused due to resonance and the vibration can cause damage to the gate. In this study, the review on amplitude of vibration and the possible resonance occurring at the time of opening or closing of gate is performed. Throughout the natural frequency analysis, the installation location of the measuring instrument was selected. On opening or closing of gate, the measurement of gate vibration is performed. The natural frequencies according to the opening range of the gate is analyzed. As a result of measurement and analysis, we proposed ranges in which vibration occurs largely and resonance is predicted as an avoiding open ranges, or the safe opening or closing of the shell-type roller gate. The application of this paper's avoiding open range estimation method of shell-type roller gate can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

수평격판을 갖는 상부가 부분 개방된 밀폐공간내의 자연대류 (Natural Convection in a Partially Opened Enclosure with a Horizontal Divider)

  • 김점수;정인기;송동주
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.528-537
    • /
    • 1995
  • Natural convective flow and heat transfer characteristics in a partially opened enclosure fitted with a horizontal divider are investigated numerically. The enclosure is composed of a lower hot and a upper cold horizontal walls and adiabatic vertical walls. A divider is attached perpendicularly to the vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations have been carried out by varying the length of divider, the opening size, and the Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height for air(Pr=0.71). As result, when the opening size is fixed, the intensity of the secondary flow is weaken as the length of divider increases. The maximum heat transfer rate over the upper cold wall occurs at a position bounded on the opening. However, when the length of divider is increased considerably, its maximum occurs at the right wall. The stability and frequency of oscillation are affected by the Rayleigh number and length of divider. The Nusselt number is increased with the increase of the opening size and the increase of Rayleigh number.

  • PDF