• Title/Summary/Keyword: Opening Load

Search Result 410, Processing Time 0.031 seconds

Modified S-FPZ Model for a Running Crack in Concrete (콘크리트의 연속적인 균열성장에 대한 수정 특이-파괴진행대 이론)

  • Yon, Jung-Heum
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.802-810
    • /
    • 2003
  • In this paper, the modified singular fracture process zone (S-FPZ) model is proposed to consider variation of a fracture criterion for continuous crack propagation in concrete. The fracture properties of the proposed fracture model are strain energy release rate at a micro-crack tip and crack closure stress (CCS) versus crack opening displacement (COD) relationship in the FPZ. The proposed model can simulate the estimated fracture energy of experimental results. The analysis results of the experimental data shows that specimen geometry and loading condition did not affect the CCS-COD relation. But the strain energy release rate is a function of not only specimen geometry but also crack extension. Until 25 mm crack extension, the strain energy release rate is a constant minimum value, and then it increased linearly to the maximum value. The maximum fracture criterion occurred at the peak load for an large size specimen. The fracture criterion remains the maximum value after the peak load. The variation of the fracture criterion is caused by micro-cracking and micro-crack localizing. The fracture criterion of strain energy release rate can simply be the size effect of concrete fracture, and it can be used to quantify the micro-tracking and micro-crack localizing behaviors of concrete.

Stress distribution of implants with external and internal connection design: a 3-D finite element analysis (내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석)

  • Chung, Hyunju;Yang, Sung-Pyo;Park, Jae-Ho;Park, Chan;Shin, Jin-Ho;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.189-198
    • /
    • 2017
  • Purpose: This study aims to analyze the stress distribution of mandibular molar restoration supported by the implants with external hex and internal taper abutment connection design. Materials and Methods: Models of external connection (EXHEX) and internal connection (INCON) implants, corresponding abutment/crowns, and screws were developed. Supporting edentulous mandibular bony structures were designed. All the components were assembled and a finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. A total of 120 N static force was applied both by axial (L1) and oblique (L2) direction. Results: Peak von Mises stresses produced in the implants by L2 load produced 6 - 15 times greater than those by L1 load. The INCON model showed 2.2 times greater total amount of crown cusp deflection than the EXHEX model. Fastening screw in EXHEX model and upside margin of implant fixture in INCON model generated the peak von Mises stresses by oblique occlusal force. EXHEX model and INCON model showed the similar opening gap between abutment and fixture, but intimate sealing inside the contact interface was maintained in INCON model. Conclusion: Oblique force produced grater magnitudes of deflection and stress than those by axial force. The maximum stress area at the implant was different between the INCON and EXHEX models.

A Study On Structural Stability Of Blast Door by Blast Pressure (폭압에 의한 방폭문의 구조적 안정성에 대한 연구)

  • Kim, Nam Hyuk;Park, Kwan Jin;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.8-15
    • /
    • 2016
  • The purpose of this study is to design a model with the structural stability so as not to lose the operational function due to structural plastic or fail of a sliding blast door by blast pressure to this aim, a numerical simulation was performed using full-size experiments and M&S (Modeling & Simulation) of the sliding blast door. The sliding blast door ($W3,000{\times}H2,500mm$) under the blast load is in the form of a sliding type 2-way metal grill, which was applied by a design blast pressure (reflected pressure $P_r$) of 17 bar. According to the experimental results of a real sliding blast door under blast load, the blast pressure reached the sliding blast door approximately 4.3 ms after the explosion and lasted about 4.0 ms thereafter. The maximum blast pressure($P_r$) was 347.7 psi (2,397.3 kPa), it is similar to the UFC 3-340-02 of Parameter(91 %). In addition, operation inspection that was conducted for the sliding blast door after real test showed a problem of losing the door opening function, which was because of the fail of the Reversal Bolt that was installed to prevent the shock due to rebound of the blast door from the blast pressure. According to the reproduction of the experiment through M&S by applying the blast pressure measurement value of the full-size experiments, the sliding blast door showed a similar result to the full-size experiment in that the reversal bolt part failed to lose the function. In addition, as the pressure is concentrated on the failed reversal bolt, the Principal Tensile Failure Stress was exceeded in only 1.25 ms after the explosion, and the reversal bolt completely failed after 5.4 ms. Based on the result of the failed reversal bolt through the full-size experiment and M&S, the shape and size of the bolts were changed to re-design the M&S and re-analyze the sliding blast door. According to the M&S re-analysis result when the reversal bolt was designed in a square of 25 mm ($625mm^2$), the maximum pressure that the reversal bolt receives showed 81% of the principal tensile failure stress of the material, in plastic stage before fail.

Extensional Buckling Analysis of Asymmetric Curved Beams Using DQM (미분구적법(DQM)을 사용한 비대칭 곡선 보의 신장 좌굴해석)

  • Kang, Ki-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.594-600
    • /
    • 2021
  • Curved beam structures are generally used as components in structures such as railroad bridges and vehicles. The stability analysis of curved beams has been studied by a large number of researchers. Due to the complexities of structural components, it is difficult to obtain an analytical solution for any boundary conditions. In order to overcome these difficulties, the differential quadrature method (DQM) has been applied for a large number of cases. In this study, DQM was used to solve the complicated partial differential equations for buckling analysis of curved beams. The governing differential equation was deduced and solved for beams subjected to uniformly distributed radial loads. Critical loads were calculated with various opening angles, boundary conditions, and parameters. The results of the DQM were compared with exact solutions for available cases, and the DQM gave outstanding accuracy even when only a small number of grid points was used. Critical loads were also calculated for the in-plane inextensional buckling of the asymmetric curved beams, and two theories were compared. The study of a beam with extensibility of the arch axis shows that the effects on the critical loads are significant.

Prediction of Continuous Discharge and Water Quality Change for Gate Operation in Seonakdong River Experimental Catchment Using SWAT (서낙동강 시험유역에서의 SWAT 모형을 이용한 수문 운영에 따른 연속유출 및 수질변화 예측)

  • Kang, Deok-Ho;Kim, Jung-Min;Kim, Tae-Won;Kim, Young-Do
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.21-33
    • /
    • 2012
  • The dominant land use at the Seonakdong river watershed is paddy and forest areas and the Seonakdong river stands still. Thus, the water pollution in the Seonakdong river is becoming more serious for the non-point source. In this study, SWAT(Soil and Water Assessment Tool) model was evaluated for simulation of flow and water quality behaviors in Seonakdong river. To perform the calibration and verification of the SWAT model, the measurements of discharge and water quality were performed for the period from 2006 to 2007 at 5 gauging stations in Seonakdong river. The $R^2$ value for discharge and water quality were 0.86 and 0.70 respectively for calibration after the sensitive analysis. The $R^2$ value for discharge and water quality were 0.81 and 0.51 respectively for verification. The simulation results show that BOD value in the river tends to decrease after the opening of gates and the patterns of TN and TP concentrations are similar as that of BOD. The gate operators need to determine how to supply water in drought season for effective water quality improvement. This study shows that the SWAT model, which is capable of simulating hydrologic and water quality behaviors temporarily and spatially at watershed scale, could be used to get the gate operation rule for the water quality management in Seonakdong river.

Fracture Behavior and Crack Growth of Concrete by The Nonlinear Fracture Mechanics (비선형 파괴역학에 의한 콘크리트의 파괴거동과 균열성장에 관한 연구)

  • 배주성;나의균
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.2
    • /
    • pp.81-92
    • /
    • 1990
  • Concrete, a mixed material, has heterogeniety, anisotrophy and nonlinearity. Therefore, in its 'racture analysis, it is more reasonable to evaluate its fracture toughness by applying the concept of 'racture mechanics rather than the strength concept. Up to the present the concepts of fracture mechanics which were applied to concrete have been divided into two main classes. The one is the concept of linear elastic fracture mechanics and the other is the concept of elastic-plastic fracture mechanics. But it has been pointed out that there are many problems and irrationalities in applying the concept of linear elastic fracture mechanics to concrete. In this study, the J -integral method and the COD method mainly used in the analysis of nonlinear fracture mechanics, were introduced and the three point bending test was carried out for investigating the effects of the variation of the maximum aggregate size and notch depth on the fracture behavior and the crack growth of concrete, and the relationships of fracture energy and crack opening displacement. According to the results of this study the more the maximum aggregate size and the notch depth increased, the more the nonlinearity of load-deflection behavior was remarkable. The increase of the coarse aggregate size created the more ductility of concrete. Thus concrete showed the more stable fracture. As for the path of the crack growth, the more the coarse aggregate size increased, the more it was irregulary deviated from the straight line but it was not almost affected by the variation of the notch depth. Also, the fracture energy increased according as the coarse aggregate size increased and the notch depth decreased.

A Study on the Libraries' Competitiveness Reinforcement Measures through SWOT Analysis : Based on the Case Study of University A's Library (SWOT 분석을 통한 도서관의 경쟁력 제고 방안에 관한 연구 - A대학교 도서관의 사례를 중심으로 -)

  • Noh, Dong-Jo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.40 no.1
    • /
    • pp.335-351
    • /
    • 2006
  • For a library to be run more efficiently, its internal strengths and weaknesses, external opportunities and threats must be determined for forecasting on the basis of the diagnosis of the internal and external environment and situations, and optimum strategies and measures responsively deducted and utilized. Therefore, I had analyzed the strategic competition of university A's library using SWOT analysis, which has recently been spotlighted as an effective strategic competition analysis method. The conclusions thus obtained are as explained below. Firstly. the strengths of university A's library are the professional qualifications of the employees. work efficiency based on systematic operative plans and division of work load, and provision of high quality service following the establishment of the digital library. Secondly, its weaknesses are the insufficiency and limits of the usable resources, the lack of progressive future operation plans and systems, and the deficiency of a positive service mind. Thirdly, the opportunities are the possibility for new developments in accordance with the digital information environment. reinforcement of the operative efficiency throughout expanding its cooperation with external organizations and other libraries, and its transformation as the local library hub by opening up to the public. Fourthly, the threats are the lack of the school authorities' acknowledgement. and the degradation of the library's status in accordance, the users' various requests for information and advanced professional service according to the rapidly changing information environment. and the restriction of the library service based on the copyright law. Fifthly, as a result of analyzing the strategic competition of university A's library, measures such as the reinforcement of digital service by acquiring digital specialists. provision of extended service through active cooperation with external institutes and libraries. development and provision of differentiated service in accordance with the reinforced copyright law were proposed to improve the library's future competitiveness.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

Development of Ultimate Strength Design Formula considering Buckling under Longitudinal and Transverse Axial Compressive Load (종횡방향 압축하중을 받는 유공판의 최종강도 설계식 개발)

  • Park Joo-Shin;Ko Jae-Yong;Lee Jun-Kyo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.173-179
    • /
    • 2006
  • A number of perforated plates are utilized for the passage of the crew and the equipment, reducing weight and the arrangement of piping. Hull girders in double bottom and floor plates are the typical parts which have those plates in a ship structure, and the perforated plate is usually positioned at the place which has less loading without local strength problems. In the case of utilizing the plate inevitably at the place which has large strength, an opening of the plate has large effect on the buckling strength due to in-plane rigidity and ultimate strength. Therefore the assessments of the elastic buckling strength and the ultimate strength for the perforated plate are the essential requirements for determining the dimensions of the parts at the initial design stage. With above reason, a need of the reasonable assessments for the elastic buckling strength and the ultimate strength has evolved. The numerical series analysis with the consideration of the effect due to various aspect ratios and slenderness ratios were performed using finite element method in this research. Simple formulas for the design are also proposed from the above analysis.

Material Properties and Structural Characteristics on Flexure of Steel Fiber-Reinforced Ultra-High-Performance Concrete (강섬유 보강 초고성능 콘크리트의 재료특성 및 휨 거동 역학적 특성)

  • Kim, Kyoung-Chul;Yang, In-Hwan;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 2016
  • This paper concerns the flexural behavior of steel fiber-reinforced ultra-high-performance concrete (UHPC) beams with compressive strength of 150 MPa. It presents experimental research results of hybrid steel fiber-reinforced UHPC beams with steel fiber content of 1.5% by volume and steel reinforcement ratio of less than 0.02. This study aims at investigating of compressive and tensile behavior of UHPC to perform a reasonable prediction for flexural capacity of UHPC beams. Tensile behavior modeling was performed using load-crack mouth opening displacement relationship obtained from bending test. The experimental results show that steel fiber-reinforced UHPC is in favor of cracking resistance and ductility of beams. The ductility indices range from 1.6 to 3.0, which means high ductility of hybrid steel fiber-reinforced UHPC. Test results and numerical analysis results for the moment-curvature relationship are compared. Though the numerical analysis results for the bending capacity of the UHPC beam without rebar is larger than test result, the overall comparative results show that the bending capacity of steel fiber-reinforced UHPC beams with compressive strength of 150 MPa can be predicted by using the established method in this paper.