• Title/Summary/Keyword: Opening Characteristic

Search Result 233, Processing Time 0.028 seconds

The Study of Space Organization and Characteristic on Chinese Traditional Courtyard in Pingyao Ancient City

  • Gao, Jie;Zhang, Junhua;Kinoshita, Takeshi
    • Proceedings of the Korean Institute of Landscape Architecture Conference
    • /
    • 2007.10b
    • /
    • pp.162-167
    • /
    • 2007
  • The courtyard life style ever existed as the major traditional living form in wide north China areas. The research made case study and specific analysis on the space organization, constitution and order of the courtyard living, as well as the dwelling accessory manners and transfer space patterns both inside and outside of the courtyard. Pingyao ancient city as the research sample (object), its courtyard composition, classification and characteristic are studied profoundly to explore local traditional cultural traits. On upon the analysis, the research is concluded that the civil courtyard in the ancient Pingyao city bears the feature of in a continuous changing process, which represented as 'from confined to opening', 'from narrow to wide', 'from public to private'. Despite of the courtyard dwelling location and direction, all accessories architectural items on the main room roof were influenced by the geomantic omen culture. As of the inside wall body, entrance and side wall of the courtyard, the woodcraft, stone carving, brick carving on above not only could functioned in architecture artistic, but also express the traditional education spiritual feature.

  • PDF

Comparison of Combustion Efficiency of Multi Hole Pintle Injector and Continuous Pintle Injector (다중 홀 핀틀 인젝터와 연속형 핀틀 인젝터의 연소성능 비교)

  • Nam, JeongSoo;Lee, KeonWoong;Koo, JaYe
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.3
    • /
    • pp.165-172
    • /
    • 2022
  • Pintle injector is the most suitable injector for thrust control because it can control the area of propellant injection. Accordingly, the combustion test of multiple hole pintle injector and continuous type pintle injector was carried out in this paper using liquid oxygen and gas methane. The combustion performance of the two pintles was verified with the characteristic speed efficiency, and the experimental results were compared according to the O/F and combustion chamber pressure and under similar conditions. The efficiency of the multi hole pintle was generally somewhat higher than continuous pintle when pintle opening distance(the area of dispensing oxidizer) was in a 100% thrust condition.

A Comparative Study on the REV, non-REV and Joint Network Methods for Analysis of Groundwater Flow in Jointed Rock Masses (절리암반내 지하수 유동해석을 위한 대표체적법, 비대표체적법 및 절리망 해석법의 비교 연구)

  • 문현구
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.217-228
    • /
    • 1999
  • The three methods of analysis (i) REV(representative elemental volume), (ii) non-REV and (iii) joint network analysis are introduced in this paper to analyze the groundwater flow in jointed rock mass and the inflow into underground excavations. The results from those methods are compared one another to reveal their characteristics by varying the number of joints and the diameter of the opening. The pre-processor, the so-called sequential analysis, is introduced to predict the equivalent hydraulic conductivity of a jointed rock mass having a number of intersecting joints. Using the finite element mesh, joint map and sequential analysis, the equivalent hydraulic conductivities are calculated for all 445 elements. The hydraulic inhomogeneity and the determination of the representative properties of jointed rock masses are discussed. In the REV analysis where the entire rock mass is homogenized through the representative properties, the inflow is increased regularly and consistently by increasing the joint density, the opening size and the conductivity contrast value. Though the non-REV analysis showed irregular variation of the inflow due to the local inhomogeneity allowed to individual elements, the inflow approached the REV results as the characteristic length increases. The joint network analysis showed the most sensitive reaction to the joint density, the opening size and the presence of the network crossing the opening. The reliability of the network analysis depends on the geometric data of individual joints. In view of the limited field data on joint geometry and possible uncertainty the REV and non-REV methods are considered more practical and rational than the joint network analysis.

  • PDF

Paleomagnetic Study on the Tertiary Rocks in Pohang Area (포항일원에 분포하는 제3기 암류에 대한 고지자기 연구)

  • Min, Kyung Duck;Kim, Won Kyun;Lee, Dae Ha;Lee, Youn Soo;Kim, In Su;Lee, Young-Hoon
    • Economic and Environmental Geology
    • /
    • v.27 no.1
    • /
    • pp.49-63
    • /
    • 1994
  • Paleomagnetic study of Tertiary rocks in Pohang area has been carried out to determine the characteristic directon of natural remanent magnetization, the position of paleomagnetic pole, the stratigraphic correlation, and the tectonic movement. A total of 196 specimens was collected from 5 sites in the Pohang Basin, 19 sites in the Janggi Basin, and 10 sites in the Eoil Basin, respectively. The mean declination and inclination of 4 sites (3 sites in the Yonil Group and 1 site in the Yonil Basalt) are $-3.2^{\circ}$ and $54.3^{\circ}$, and yield the paleomagnetic pole position $86.9^{\circ}N$ and $7.7^{\circ}E$. These are the characteristic direction and pole position of Miocene Epoch by comparison with contemporary Eurasian and Chinese data. The characteristic direction and pole position of remaining 30 sites are $47.6^{\circ}$ and $57.5^{\circ}$, and $52.3^{\circ}N$ and $201.5^{\circ}E$, respectively. These show clockwise rotation of $50.8^{\circ}$ with respect to the Miocene ones resulted by a tectonic movement before the deposition of the Hakjeon Formation of the Yonil Group about 15~16 Ma in the study area. The mechanism of the clockwise rotation is considered to be the dextral movement of the Yangsan Fault presumably caused by the opening of the East Sea. The Yonil Basalt is reclassified into pre- and post-deposition of the Yonil Group, i.e. the former is early Miocene and the latter late Miocene.

  • PDF

Paleomagnetic Study of the Yeonil Group in Pohang Basin (포항분지(浦港盆地)에 분포(分布)하는 연일층군(延日層群)의 고지자기(古地磁氣) 연구(硏究))

  • Kim, Kwang Ho;Doh, Seong-Jae;Hwang, Chang-Soo;Lim, Dong Seong
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.507-518
    • /
    • 1993
  • Paleomagnetic investigations have been carried out on the Tertiary sedimentary formations (Yeonil Group) in Pohang basin, southeastern Korea. A total of 215 samples were collected from 26 sites. Progressive thermal demagnetization indicates that many samples have unstable magnetization and do not reveal a characteristic direction. However, some samples from the lower and upper Duho Formation show a characteristic direction $D/I=7.8^{\circ}/48.3^{\circ}$ (${\alpha}_{95}=3.7^{\circ}$, k=174.1). Stepwise thermal demagnetization data show that some samples from the Hagjeon and middle Duho Formations reveal great-circle distributions moving from the present to a reversed direction of geomagnetic field. The mean of intersection points of the great-circles is nearly antipodal to the characteristic normal direction of the lower and upper Duho Formation. We infer that the Hagjeon Formation was formed during the reversed polarity chron C5B (16.2~14.7 Ma) and the Duho Formation 14.7~11.6 Ma based on our results and previous paleontologic and age dating data. Paleomagnetic direction for the Middle Miocene of Korea, analysed from the combined results of stable endpoints and great circles, is $D/I=8.7^{\circ}/53.9^{\circ}$ (${\alpha}_{95}=4.2^{\circ}$, k=74.8), and the corresponding paleopole is Lat./Long.=$82.7^{\circ}/230.2^{\circ}$ (${\delta}p=2.8^{\circ}$, ${\delta}m=5.9^{\circ}$). On the basis of this, we interpret that the opening of the East sea (Japan sea) or the synchronous clockwise rotation of the Southwest Japan exerted no structural influence on the Yeonil Group in the Middle Miocene.

  • PDF

Sliding Ceiling Panel Structure (미닫이 천정판 구조)

  • Gook, Seung-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1478-1485
    • /
    • 2011
  • Subway stations have a characteristic that the facilities in the ceiling should be checked, replaced or expanded frequently. The frequent opening and closing of ceiling panels result in the damage of panels which makes them easily disengaged. In order to resolve this issue, which is giving difficulty in the maintenance of the stations, this study suggest a sliding ceiling panel structure which can be opened and closed with sliding mechanism, instead of current fixed type ceiling panels. The sliding ceiling panel will prevent the damage of ceiling panels due to frequent disengagement and engagement. It will increase the durability of ceiling panel and extend the cycle of panel replacement. Accordingly, the maintenance cost will be also reduced.

  • PDF

Internal Flow Characteristics of a Steelworks Sintering Cooler by the Duct Shape of Cooler Fan Outlet (제철소 소결냉각용 축류송풍기 출구 덕트 형상에 따른 내부유동특성)

  • Choi, Young-Do;Kim, Kyoung-Hoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.72-77
    • /
    • 2014
  • Because of overload working condition of sintering cooler, the cooler fan often suffers the break or damage of rotor blade and fixing shaft. Therefore, internal flow characteristics of a steelworks sintering cooler fan by the duct shape of the cooler fan outlet, such as duct outlet opening ratio, duct height and dividing wall shape on the duct outlet flow pattern are examined in detail. The results show that relatively short duct wall height and attachment of dividing wall shape improves flow patterns considerably.

The Cycle Analysis of 4 Valve-type Pulse Tube Refrigerator (4 밸브형 맥동관 냉동기의 사이클 해석)

  • Cho, Kyung-Chul;Lee, Sang-Won;Lim, Young-Hun;Kim, Soo-Yun;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.636-641
    • /
    • 2001
  • In this paper, we constructed four valve type pulse tube refrigerator and found the characteristic of orifice (needle valve) opening for using phase shifter and optimum cycle time - The valve timing was controlled by the digital timers. The experimental results showed the optimum frequence and cycle time at operating conditions. The results showed that the optimum process time existed and the rate was same at each operating frequence. The no- load temperature of the refrigerator was 85K.

  • PDF

The study on characteristic of efflorescence phenomenon and reduction plan through research (사례 조사를 통한 백화현상의 특징 및 저감 방안 연구)

  • 박영민;이희두;이해진;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.1-6
    • /
    • 2002
  • The study offer a suggestion that from result in being a case to efflorescence for decrease a plan: $\circled1$ A efflorescence of concreat a structure will be the prograss plan; In the materials, depress use to the water-sand in the construction, admonish unification of front and rear in the environment, consideration requisite concreat don't the occurrence efflorescence. $\circled2$ Ma sonry building efflorescence establish a ventilation opening and a waterway to ma sonry the times avoid the winter or the rainy season. Ma sonry building efflorescence will be make good among a brick to a brick interval closely mortar. $\circled3$ Tile building, tile of plasticity temperature is appropriate, reduce the deviation, parapet part of efflorescence will be make good closely mortar. A construction material part a meterial developing need Perfection of construction a efflorescence occurrence is the minimum, a plan Part developed so on, composition of a ommection field systematic effort need a efflorescence Prevention a kind of detail.

  • PDF

The Analysis of Circumference Through-Wall Cracked Pipe Considering Weld Characteristic (용접부 강도불균질을 고려한 원주방향관통균열 배관의 파괴역학 해석법)

  • Park, Bo-Gyu;Oh, Chang-Kyun;Kim, Yun-Jae;Kim, Young-Jin;Kim, Jong-Sung;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.31-36
    • /
    • 2004
  • Defective components of interest include not only homogeneous components, but also components with weldments where tensile properties vary across the weldment. Noting that the region near the weldment is the most vulnerable place for crack initiation and subsequent growth, defect assessment methods for homogeneous structure. Moreover, weldment width and crack location also affects the deformation and fracture behavior of the welded joints. These weld characteristics can evaluate using plastic limit load. So in this paper, evaluate plastic limit load both full circumference part-throughwall cracked pipes and circumference through-wall cracked pipes considering weld characteristics. And using evaluate results, proposed J-integral and crack opening displacement(COD) estimate method based on reference stress method.

  • PDF