• Title/Summary/Keyword: Open-tube

Search Result 311, Processing Time 0.024 seconds

Impedance Tube Measurements of Sound Absorbing Materials: Sensitivity Analysis on Backing Conditions (임피던스 관을 이용한 흡음재의 특성 임피던스 측정: 배후조건에 따른 민감도 분석)

  • 이종화;이정권;박봉현;김병훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.888-891
    • /
    • 2001
  • Effects of backing conditions on the impedance tube measurement are investigated experimentally, by using several pairs of generally employed end conditions. The results show that the measured values are similar for most of pairs, except the case of using an open pipe condition. In addition, the random error is investigated in the viewpoint of the variation of test conditions. The multi-termination method is suggested for minimizing such a random error.

  • PDF

Open Die Forging of the Large Steel Forgings for Steam Generator (증기발생기용 대형 단강품의 자유단조)

  • 김동권;김재철;김영득;김동영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.39-42
    • /
    • 2003
  • Steam Generator has been manufactured by welding process after partial manufacturing of various steel forgings such as shell, head and tube sheet. Usually, these steel forgings are made by open die forging process. After steel melting and ingot making, open die forging has been carried out to get a good quality which means high soundness and homogeniety of the steel forgings by using high capacity hydraulic press. This paper introduced open die forging development status of the large steel forgings which is used for the steam generator of 1,400MW next generation nuclear power plant.

  • PDF

Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD (전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석)

  • Nam, Ki-Won;Min, Jun-Kee;Jeong, Ji-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.491-499
    • /
    • 2010
  • Heat transfer performance of tube bundles have long been investigated since they were widely used. Most of previous experimental and numerical works for tube bundles were performed with tube diameter in the range of 25~51mm and Reynolds number of $8.000{\leq}Re{\leq}30.000$. Recently, tube bundles with small diameter tube collects interests since the mini-channel tube provides higher compactness. The present work aims to investigate the applicability of previous correlations available in the open literature to the tube bundles with small diameter of 1.5mm and $3.000{\leq}Re{\leq}7.000$. A commercial CFD package was used to analyze the thermal-hydraulic performance of them. The results show that the Zukauskas correlation developed for larger diameter tube and higher Reynolds number are still in good agreement with them within the discrepancy of 4.7%. The analyses also show that the Nuselt number increases with a decrease in the longitudinal pitch.

Numerical Study on Laser-driven In-Tube Accelerator (LITA) Performance using a Plasma Size Modeling

  • Kim, Sukyum;Toshiro Ohtani;Akihiro Sasoh;Jeung, In-Seuck;Park, Jeong--Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.320-324
    • /
    • 2004
  • Laser Propulsion is a device that generates thrust using laser energy. Laser-driven In-Tube Accelerator (LITA) has been developed at Tohoku University. LITA is a laser propulsion system that accelerates an object not in an open air but in a tube. Experiments of vertical launching and pressure measurement on the tube wall were carried out and in order to observe the initial state of plasma and blast wave, the visualization experiment was carried out using the shadowgraph method. In this study, the time variation of pressure on the tube wall is numerically simulated solving Euler equation. In order to model the laser energy, heat source function added to the frozen flow Euler equation. Plasma size from the shadowgraph images was used for the initial condition of laser energy input. For verification of the modeling, these results were compared with the previous experimental and numerical results. From these verifications, an analysis of LITA performance will be investigated.

  • PDF

Fabrication and Characteristics of Anode-supported Tubular Solid Oxide Fuel Cell (연료극 지지체식 원통형 고체산화물 연료전지의 제조 및 특성)

  • Song, Keun-Sik;Song, Rak-Hyun;Ihm, Young-Eon
    • Korean Journal of Materials Research
    • /
    • v.12 no.9
    • /
    • pp.691-695
    • /
    • 2002
  • A low temperature anode-supported tubular solid oxide fuel cell was developed. The anode-supported tube was fabricated using extrusion process. Then the electrolyte layer and the cathode layer were coated onto the anode tube by slurry dipping process, subsequently. The anode tube and electrolyte were co-fired at $140^{\circ}C$, and the cathode was sintered at $1200^{\circ}C$. The thickness and gas permeability of the electrolyte depended on the number of coating and the slurry concentration. Anode-supported tube was satisfied with SOFC requirements, related to electrical conductivity, pore structure, and gas diffusion limitations. At operating temperature of $800^{\circ}C$, open circuit voltage of the cell with gastight and dense electrolyte layer was 1.1 V and the cell showed a good performance of 450 mW/$\textrm{cm}^2$.

A Comparison Study of Educational Needs Following Open-Heart Surgery Assessed by Nurses and Patients Themselves (개심수술후(Open-Heart Surgery) 환자의 교육 요구에 관한 간호원과 환자와의 비교연구)

  • 김금순;조경숙
    • Journal of Korean Academy of Nursing
    • /
    • v.14 no.2
    • /
    • pp.12-18
    • /
    • 1984
  • The purpose of this study was to compare educational needs following open heart surgery assessed by nurses & patients themselves, Data were collected from Nov. 1983 to Jan. 1984 through administration of Questionnaire developed for this study by the researcher. The subjects were 45 patients who experienced open heart surgery and 29 nurses who taking care of these patients in chest surgery ward at Seoul National University Hospital. The Data were analyzed by T-test and One Way ANOVA according to dependent variables. The result were as follows 1. There are significant difference between educational needs, assessed by nurses and patients themselves. (p<0.05) The nurses reported higher score of educational needs than patients. 2. In comparison of content area of educational needs, there was significant difference according to respiratory care, fain, chest tube care and operation including heart function between two groups. But, there was no significant difference in diet, activity, complication, emotional care and medication between two groups. 3. The priorities in content area of educational needs rated by nurses and patients were similar.

  • PDF

Discussions on the Leak Phenomena of Liquid Butane in the Open Air (액화석유가스(butane)의 대기중 누출현상에 대한 고찰)

  • Yoon, Jae-Kun
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2000
  • Almost accidents related with gas have started with the leakage of LPG(Liquefied Petroleum Gas) in the open air. But experimental data of LPG leak jet are difficult to find because the safety of experiment is hard to secure and its phenomenon is not steady but transitional. This study is focused on the phenomena of injection jet of liquid butane to the open air. Simple experiment shows that only liquid butane jet in the open air is possible due to the slow vaporization because of low temperature difference between the liquid and air and low vapor pressure of liquid butane. Comparing with the water, 25~40% more liquid butane flow through the tube under the same pressure difference driving.

  • PDF

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

Correction of Coarctation in Infants Less than Age 3 Months (3개월 이하 영아의 대동맥 축착증 수술치료에 대한 임상연구)

  • Sin, Je-Gyun;Song, Myeong-Geun
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1139-1145
    • /
    • 1990
  • Seven infants less than age 3 months underwent patch aortoplasty and tube graft bypass for relief of coarctation of aorta. All had intractable congestive heart failure, despite aggressive medical therapy Each infant had other cardiac anomalies including patent ductus arteriosus, ventricular septal defect, atrial septal defect and congenital mitral stenosis. All patients underwent closure of the ductus arteriosus and patch angioplasty of the aorta to produce a luminal diameter of at least 15mm or tube graft interposition utilizing the Gortex tube graft diameter larger than 10mm. In 5 patients who had ventricular defect, they underwent pulmonary arterial banding. &ere was one hospital death 17 days after operation secondary to the hydronephrosis and renal failure. Hospitalization was less than 10 days after operation except one case. In 3 patients who had associated VSD, open heart surgery[VSD closure+PA debanding]was done without difficulty. Surgical repair of critical coarctation of the aorta in infants can safely be offered despite the poor preoperative condition and presence of other cardiac anomalies.

  • PDF

EFFECTS OF GEOMETRIC PARAMETERS ON NUCLEATE POOL BOILING OF SATURATED WATER IN VERTICAL ANNULI

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • Nucleate pool boiling of water in vertical annuli at atmospheric pressure has been studied experimentally and two empirical correlations have been suggested to obtain effects of geometric parameters on heat transfer. Data of the present and the previous tests range over a tube length of 0.50-0.57 m, a diameter of 16.5-34.0 mm, and an annular gap size of 3.7-44.3 mm. Through the analysis, tube bottom confinement (open or closed) has been investigated, as well. The developed correlations predict experimental data within a ${\pm}25%$ error bound. It has been identified that effects of the diameter and the length of heated tubes as well as the annular gap size should be counted into the analyses to estimate heat transfer coefficients accurately.