• Title/Summary/Keyword: Open-coil spring

Search Result 16, Processing Time 0.026 seconds

A STUDY ON THE MECHANICAL PROPERTIES OF ORTHODONTIC OPEN COIL SPRINGS (교정용 open coil spring의 역학적 특성에 관한 연구)

  • Park, Kyu-Chan;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.135-146
    • /
    • 1992
  • It was the purpose of this study to analyze and compare the mechanical properties of ortho dontic open coil springs. Four variable factors were presented - wire diameter (.008", .009", .010"), lumen size (.030", .032", .036"), arch wire size and shape (.016" round, $ .016^{{\prime}{\prime}}{\times}.022^{{\prime}{\prime}}$ rect.) and alloy type (HiT II, Elgiloy, Sentalloy). The total 104 specimens were divided into 13 groups, and compression test was performed on an Instron test machine. The load deflection curve of each open coil spring was obtained, from which, the load-deflection relations, stiffnesses, percent recoveries were computed statistically. The results were obtained as follows: 1. When the lumen size of the coil spring remained constant, stiffness and percent recovery increased as the wire diameter increased. 2. When the wire diameter of the coil spring remained constant, stiffness and percent recovery decreased as the lumen size increased. 3. The effect of size and shape of arch wire on the coil spring was not statistically significant. 4. In alloy types, stiffness was the greatest in HiT II (55.21), Elgiloy (42.61) and Sentalloy (7.74) in that order. Sentalloy exhibited superior percent recovery and long range of action.

  • PDF

A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION IN THE ALVEOLAR BONE BY VARIOUS MOLAR UPRIGHTING SPRINGS (Molar Uprighting Spring에 의해 발생되는 치조골내의 응력분포에 관한 광탄성학적 연구)

  • Choi, Jin-Hugh;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.353-366
    • /
    • 1991
  • This study was performed to analyze the effects of forces to the alveolar bone by various molar uprighting spring such as helical uprighting spring. T-loop spring, Modified T-loop spring and open coil spring. The simplified two-dimensional photoelastic model was constructed with a lower left posterior quadrant containing the second molar, the first and second premolars and the canine, with the first molar missing. Several molar uprighting springs were fabricated from 0.017 by 0.022 inch blue Elgiloy and applied to the photoelastic model. Two-dimensional photoelastic stress analysis was performed, and the stress distribution was recorded by photography The results obtained were as follows; 1. In all the kinds of the springs, the center of rotation of the mandibular second molar was oserved at the apical 1/5-1/6 between the alveolar crest and the root apex. 2. In all the kinds of the spring, the stress induced in the mesial root surface of the mandibular second molar was relatively homogeneous but there was some difference in the magnitude of the stress. 3. In the kinds of the springs, the distal crown tipping moment of the second molar was increased in turn as open coil spring, helical uprighting spring, T-loop spring, and modified T-loop spring. 4. The largest extrusive force was occured in the T-loop spring, intrusive force was occured in Modified T-loop spring only, and the largest distal tipping force was occured in open coil spring. 5. In the T-loop spring with activation, the stress induced in the mesial root surface of the second molar was increased gradually from the root apex to the alveolar crest and highly concentrated in the alveolar crest.

  • PDF

High-Precision Direct-Operated Relief Valve with a Variable Elasticity Spring (변탄성 스프링을 이용한 고정밀 직동형 릴리프 밸브)

  • Kim, SungDong
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.87-96
    • /
    • 2020
  • In this study, a variable elasticity spring was applied to improve the pressure control precision of conventional relief valves. The equilibrium equation of the forces acting on the valve poppet was derived; it is demonstrated that matching the elastic rate of the pressure-adjusting coil spring to the equivalent elastic rate of the flow force improved the pressure override. The procedures that were used to design the variable elasticity spring are presented, and some applications of the variable elasticity spring are also introduced. Computer simulations were used to analyze three cases: a poppet-closed flow force structure, a poppet-open flow force structure with a constant elasticity spring, and a structure containing a variable elasticity spring. It is confirmed that the pressure control precision of the relief valve can be significantly improved upon by applying a variable elasticity spring to the poppet-open flow force structure.

A Study on the Contour Design of the Hinge Mechanism for a Mobile Phone Driven by Continuous Torques (연속적인 회전력으로 작동하는 휴대폰 힌지기구의 윤곽 설계에 관한 연구)

  • Park, Jong-keun;Lee, Soo Jun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.3
    • /
    • pp.8-18
    • /
    • 2010
  • A total stroke of an opening or closing motion of a hinge mechanism for a folder-type mobile phone is composed of two portions. In the first portion, human fingers act a torque to open or close the folder. In this portion, the rotating folder compresses the coil spring installed in the hinge mechanism. In the last portion, this compressed coil spring generates a torque to rotate the folder. In this study, we have developed an algorithm to design a hinge mechanism to be operated by an arbitrary continuous torque in the first portion of the total stroke. Consequently, we can design hinge mechanisms that satisfy various demands of consumers. A pair of contours installed in the mechanism plays an important role. It transforms the folder's rotational motion into translation to compress the coil spring in the first portion; on the other hand, it transforms translational motion into the folder's rotation in the last portion. Using this algorithm we have designed the pair of the contour curves operated by an arbitrary continuous torque.

TREATMENT OF THE IMPACTED LOWER SECOND MOLARS (매복된 하악 제2대구치 맹출유도의 치험례)

  • Hahn, Soo-Kyoung;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In the normal growth and development of the mandible, the molar tooth buds distal to the first permanent molar have a mesial inclination. This inclination is usually self-correcting, but, unfortunately, this self-correction does not always occur. The first case is about, 14-year-old female patient with familial history of lower second molar impaction. Her lower second molars were both impacted, and she was treated with sectional wires and open-coil springs. The second case, 14-year-old male, we treated his impacted #47 with Halterman appliance. The third case, 11-year-old male, his both mandibular second molars were impacted during full-fixed orthodontic treatment. They were treated with brass wire, sectional wire and open-coil spring.

  • PDF

A Study on the Optimal Design of Gas Spring for Vehicle (자동차용 GAS SPRING의 최적 설계에 관한 연구)

  • 김영범
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.39-45
    • /
    • 1998
  • Gas springs have been widely used in motor vehicles as well as in most areas of industry. Instead of coil springs, these gas springs are easily opreated to open(extension process) or close (compression process) the doors because $N_2$ gas with high pressure and oil are charged in tube. Most of manufacturers are using the trial & error method in order to decide its specification(reaction force, damping force), which tends to waste time and money. Therefore, gas springs have been improved by properly changing the control pressure of $N_2$ Gas with its mounting location and weight to maximize its effect and to minimize its space. Although it has been researched on damping structure to minimize impact which is applied to vehicle when its back door is fully opened, the characteristics of damping structure are not known clearly. There(ore, this paper will not only clearly define the effect of important factors(open & close force)for gas springs through theoretical analysis but also provide optimum design specification through development of program to avoid traditional method of specification determination such as the trail It error method which is widely used in whole industries including automotive industry.

  • PDF

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

A Study on the Contour Design in the Hinge Mechanism for a Folder of a Mobile Phone (휴대폰 폴더용 힌지기구의 윤곽 설계에 관한 연구)

  • Park, Jong-Keun;Lee, Soo-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.86-94
    • /
    • 2008
  • A total stroke of an opening or closing motion of a hinge mechanism in a folder-type mobile phone is composed of two portions. In the first portion, human fingers act a force to open or close the folder. In this portion, the rotating folder compresses the coil spring installed in the mechanism. In the last portion, this compressed coil spring generates a torque to rotate the folder. The main merit of this study is that we have designed a hinge mechanism to be operated by a uniform torque in the first portion of the total stroke. The uniform torque means that it is constant along the folder's swing angle. This mechanism will give softer feeling to human fingers. A pair of contours in the mechanism plays an important role. It transforms rotation into translation in the first portion; on the other hand, it transforms translation into rotation in the last portion. In this study, we have developed an algorithm to obtain the pair of contour curves. We divided the total contour curves into finite sub-intervals. Assuming that the curves in every sub-interval are parabolas, we have obtained the coefficients of them by solving systems of nonlinear equations recursively.

A SOFT X-RAY STUDY ON THE BONE REMODELLING IN TOOTH MOVEMENT OF DOG (성견의 실험적 치아이동시 골재형성에 관한 연X선학적 연구)

  • Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.587-592
    • /
    • 1995
  • The purpose of this study was to observe the pattern of bone remodellings in the periodontal ligament of dog, in which experimental tooth movement was performed A control and 5 experimental dogs, one and half year in age, were studied. Light force (50-75g) was applied by placing open-coil spring between left mandibular premolars ; heavy force (250-300g), between right mandibular premolars. Experimental dogs were sacrificed at 12 hours, 1, 3 ,7 and 14 days after force application, respectively. And soft X-ray films were obtained and read on the sectioned periodontal tissue around mandibular premolars. The results were as follows. 1. New bone formation began to be observed in tension side at 7-day and increased at 14-day , No difference was observed between light force group and heavy force group. 2. Bone resorption was observed as a shape of destruction of lamina dura at 3-day and increased gradually at 7-day, 14-day.

  • PDF

Retrograde Left Cardioangiography -Its Diagnostic Value in the Mitral Valvular Heart Disease- (역행성 좌심실 촬영술의 임상적 의의)

  • 손광현
    • Journal of Chest Surgery
    • /
    • v.2 no.1
    • /
    • pp.77-84
    • /
    • 1969
  • Retrograde left cardioangiographic studies using Amplatz spring coil guide catheter were carried out in 30 cases of acquired mitral valvular diseases. Of these 12 cases were compatible with the clinical diagnosis which were made pre-angiocardiographically. Eighteen out of 30 cases were diagnosed as pure mitral stenosis or mitral insufficiency which had been clinically diagnosed as mitral stenoinsufficiency or mitral stenosis with aortic insufficiency. The rate of difference is 60%. Twenty-five cases or 83% of all cases were operated. Of these 6 cases, the degree of regurgitation through the mitral valves were able to be evaluated cardioangiography and were confirmed by open heart operation. The retrograde left cardioangiography is considered to be a useful tool in conclusive dianosis of clinically equivocal mitral valvular diseases.

  • PDF