• 제목/요약/키워드: Open storage

검색결과 395건 처리시간 0.026초

Mobile Art Park Guidance Application using Mobile MAP Open API

  • Jwa, Jeong-Woo;Ko, Sang-Bo;Lee, Deuk-Woo
    • International Journal of Contents
    • /
    • 제7권2호
    • /
    • pp.11-16
    • /
    • 2011
  • In this paper, we develop a mobile MAP open API using HTML5 local storage and the W3C geolocation API. The mobile MAP open API consists of the basic JavaScript MAP API, offline navigation API, and multimedia POI (mPOI) API. The basic JavaScript MAP API creates a map and controls, rotates, and overlays data on the map. The offline navigation API is developed using HTML5 local storage and web storage. The mobile web application downloads and stores mPOIs of works of art to local storage or web storage from a web server. The mPOI API is developed using HTML5 video and audio APIs. We develop a mobile art park guidance application using the developed mobile MAP open API.

가정용 냉장고에서 동결저장 중의 가리비의 품질 변화 (Quality Changes of Frozen Scallop[Patinopecten yessonensis(Jay)] Stored in theDomestic Refriogerator)

  • 김상무
    • 한국식품영양과학회지
    • /
    • 제26권3호
    • /
    • pp.450-455
    • /
    • 1997
  • Scallop, Patinopecten yessonensis(Jay), cultivated in the cold east coast of Kwangwon region, Korea, is expected to be producted to about 50,000 tones in 2000 year. Freezing is one of the most effective methods applied for soraging seafoods. But, the domestic refrigerator with an automatic defrost system shows the temperature fluctuation during defrosting, thus might result in the deterioration of the frozen foods. In this study, the domestic refrigerator with an automatic defrost system, temperature fluctuation from -18 to -5$\pm$1$^{\circ}C$ and fluctuation intervals from 16 to 20 hr, was used for storing scallop. pH was decreased rapidly after 3 month storage, while the content of amino nitrogen was increased continuously. The TMA content of open state was increased very rapidly on 3 month storage and then increased slowly, whereas that of vinyl package increased slowly. The VBN content was increased almost constantly with no significant differences between storage methods. The TBA content was increased up to 3 month storage with the higher value in open state than vinyl package in the beginning periods of storage, and then decreased very rapidly. The number of total viable cell was increased continuously during storage with higher number in open state than vinyl package. The estimated shelf-lives of frozen scallop with open state and vinyl package stored at -18$^{\circ}C$ in the domestic refrigerator with an automatic defrost system were 3.55 and 3.78 months, respectively.

  • PDF

개가식 도서관의 공간효율 제고 방안 -지역 대학도서관 서고 공간을 중심으로- (Space Efficiency Improvement for Open Access Library -Focused on Book-storage Space of Academic Libraries in Province Area-)

  • 안준석
    • 한국농촌건축학회논문집
    • /
    • 제17권4호
    • /
    • pp.67-74
    • /
    • 2015
  • Due to an inability to accommodate for the rapidly increasing number of printed materials, Korean academic libraries are facing serious space shortage problems. Very few academic institutions have the funds to expand existing libraries or construct new facilities in order to accommodate the influx of printed materials. Despite not having the luxury to create new space, many establishments continue to implement the open access system. Seeing that such a system is only user friendly when used in a spacious facility, the maintenance of the open access system is unreasonable. Only few libraries consider the space efficient closed access system which helps to resolve storage space shortage. In the current state of the problem, improving the efficiency to which books are stored in existing storage areas within a library facility is the only appropriate solution. Enacting methods to improve physical space utilization within a fixed volume library facility will undoubtedly diminish the space shortage issue at hand. In this article, several space efficiency improvement approaches are discussed. Methods of book storage plan re-layout (floor, plan, ceiling, height, bookshelf design), book arrangement possibilities, and the reduction of the physical volume of reserved materials are each examined.

STEP 데이터베이스를 Native Storage로 가지는 3차원 선체 CAD에서 형상 모델링 커널과 데이터베이스간의 인터페이스 (Interface between Geometric Kernel and Database for a Ship CAD which has a STEP Database as the Native Storage)

  • 김준환;한순흥
    • 한국CDE학회논문집
    • /
    • 제7권3호
    • /
    • pp.202-209
    • /
    • 2002
  • It is difficult to support collaborative design with a conventional ship CAD system which manages design information using files. In this research, file storage has been replaced with a database. This paper describes the OpenDIS which is an interface between the geometric kernel and the database. Its main purpose is to implement the CAD system which has the STEP database as the native storage. A prototype CAD system has been implemented using that OpenDIS interface which is implemented by OpenCascade geometric kernel and the Objectstore object-oriented database. The STEP methodology is used as the database schema. This CAD system has been applied to the hull design of a ship in order to verify the usefulness of the interface.

THE OPEN-CIRCUIT VOLTAGE STATE ESTIMATION OF THE BATTERY

  • LEE, SHINWON
    • Journal of applied mathematics & informatics
    • /
    • 제39권5_6호
    • /
    • pp.805-811
    • /
    • 2021
  • Currently, batteries use commonly as energy sources for mobile electric devices. Due to the high density of energy, the energy storage state of a battery is very important information. To know the battery's energy storage state, it is necessary to find out the open state voltage of the battery. The open state voltage calculates with a mathematical model, but the computation of the real time state is complicated and requires many calculations. Therefore, the state observer designs to estimate in real time the battery open-circuit voltage as disturbance including model error. Using the estimated open voltage and applying it to the state estimation algorithm, we can estimate the charge. In this study, we first estimate the open-circuit voltage and design an estimation algorithm for estimating the state of battery charge. This includes errors in the system model and has a robust characteristic to noise. It is possible to increase the precision of the charge state estimation.

유닛로드형 자동창고의 수행도 분석 (Performance Analysis of Unit-load AS/R Systems)

  • 김남하;임석철;홍석교;이수훈;홍만표
    • 대한산업공학회지
    • /
    • 제20권2호
    • /
    • pp.39-50
    • /
    • 1994
  • Most research results on the throughput of unit-load automated storage retrieval (AS/R) systems assume the randomized storage; that is, all slots In the entire rack are equally likely to be selected for the storage location. However, for the most existing AS/R systems which use Closest Open location storage policy, Park[6] mathematically showed that this assumption results in a significant difference from the actual performance of AS/R systems. In this study, we present more details about the performance of the unit-load AS/R systems by considering the rack utilization and rack density; and examine their impact on the throughput of AS/R systems by using computer simulation. A new storage policy named Shortest Cycle Location(SCL) is proposed. Simulation results indicate that the performance of SCL policy consistently outperforms the Closest Open location storage policy. We also define the "Extra-Cost Zone" compared to the "No-Cost Zone"[3] and explore its geometric and practical meaning.

  • PDF

노천채굴적 내 광미 적치 시나리오 구축 및 천반 수평필러 안정성 분석 (Establishment of Tailing Disposal Scenario in Open-Pit and Surface Pillar Stability Analysis)

  • 강일석;송재준
    • 터널과지하공간
    • /
    • 제34권1호
    • /
    • pp.54-70
    • /
    • 2024
  • 생산이 완료된 노천광산 채굴적을 광미(광물찌꺼기) 적치 장소로 활용하는 방안은 기존 광미 적치 시설(TSF, Tailing storage facility)의 설치 공간 및 운영비용 문제 해결을 위한 대안으로 제시된다. 하지만 장기간에 걸쳐 적치된 광미는 주변 암반에 추가적인 하중으로 작용하여 광산의 역학적 안정성을 저해할 위험성이 존재한다. 본 연구에서는 호주 Marymia 광산의 사례를 참고하여 약 60,400 시간에 걸친 광미 적치 시나리오를 구축하였으며, 다양한 지하 채광장 형태 및 암반 조건에 따른 천반 수평필러의 역학적 안정성을 Sigma/W 해석 소프트웨어를 활용하여 분석하였다. 분석 결과, 광미 적치가 장기간 지속됨에 따라 천반 수평필러의 파괴 가능성이 유의미하게 증가함을 확인하였다. 해당 결과는 노천채굴적 내 광미 적치 시 광산 구조에 대한 역학적 안정성 고려가 필수적임을 시사한다.

A Disk-based Archival Storage System Using the EOS Erasure Coding Implementation for the ALICE Experiment at the CERN LHC

  • Ahn, Sang Un;Betev, Latchezar;Bonfillou, Eric;Han, Heejune;Kim, Jeongheon;Lee, Seung Hee;Panzer-Steindel, Bernd;Peters, Andreas-Joachim;Yoon, Heejun
    • Journal of Information Science Theory and Practice
    • /
    • 제10권spc호
    • /
    • pp.56-65
    • /
    • 2022
  • Korea Institute of Science and Technology Information (KISTI) is a Worldwide LHC Computing Grid (WLCG) Tier-1 center mandated to preserve raw data produced from A Large Ion Collider Experiment (ALICE) experiment using the world's largest particle accelerator, the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN). Physical medium used widely for long-term data preservation is tape, thanks to its reliability and least price per capacity compared to other media such as optical disk, hard disk, and solid-state disk. However, decreasing numbers of manufacturers for both tape drives and cartridges, and patent disputes among them escalated risk of market. As alternative to tape-based data preservation strategy, we proposed disk-only erasure-coded archival storage system, Custodial Disk Storage (CDS), powered by Exascale Open Storage (EOS), an open-source storage management software developed by CERN. CDS system consists of 18 high density Just-Bunch-Of-Disks (JBOD) enclosures attached to 9 servers through 12 Gbps Serial Attached SCSI (SAS) Host Bus Adapter (HBA) interfaces via multiple paths for redundancy and multiplexing. For data protection, we introduced Reed-Solomon (RS) (16, 4) Erasure Coding (EC) layout, where the number of data and parity blocks are 12 and 4 respectively, which gives the annual data loss probability equivalent to 5×10-14. In this paper, we discuss CDS system design based on JBOD products, performance limitations, and data protection strategy accommodating EOS EC implementation. We present CDS operations for ALICE experiment and long-term power consumption measurement.

사용자 정보를 이용한 인증 절차 자동화 (Automate authentication processes with user information)

  • 황우섭;박지수;손진곤
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2019년도 추계학술발표대회
    • /
    • pp.1125-1128
    • /
    • 2019
  • 사용자가 인터넷을 사용할 때 화면에 표시되는 텍스트나 그래픽 등을 웹 문서라고 하며 HTML5는 웹 문서를 제작하는 표준 언어의 일종이다. HTML5 중에서 web storage는 사용자가 인터넷을 통한 서비스를 받을 때 데이터를 저장하기 위한 기능으로 키와 값의 형태로 저장한다. web storage는 서버 측에서 사용되는 session storage와 클라이언트에서 사용되는 local storage가 있다. local storage 사용 시 데이터를 클라이언트에 평문 형태로 저장하며 만료 기간 없이 영구적인 특징을 갖고 있다. 이러한 특징은 공격자로부터 XSS 등의 공격에서 저장된 데이터의 접근 및 수정 그리고 탈취할 수 있어 공격자의 의도에 따라 데이터 가공 및 재사용이 가능하다는 문제가 있다. 보안 취약점 문제를 해결하기 위한 최근 연구들은 local storage에 저장된 데이터들을 암호화하여 기밀성을 높였다. 그러나 데이터 암호화를 사용하려면 잦은 암호 입력이나 온라인에서만 사용할 수 있다는 또 다른 문제점을 가지고 있다. 기존 보안 취약점 문제와 기존 연구의 문제점을 동시에 해결하기 위해 운영체제 사용자 정보와 기기의 정보를 활용하여 암호화에 필요한 사용자 인증을 자동화하였으며 검증을 위해 코드를 구현하고 테스트 하였다.

Modelling of the fire impact on CONSTOR RBMK-1500 cask thermal behavior in the open interim storage site

  • Robertas Poskas;Kestutis Rackaitis;Povilas Poskas;Hussam Jouhara
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2604-2612
    • /
    • 2023
  • Spent nuclear fuel and long-lived radioactive waste must be carefully handled before disposing them off to a geological repository. After the pre-storage period in water pools, spent nuclear fuel is stored in casks, which are widely used for interim storage. Interim storage in casks is very important part in the whole cycle of nuclear energy generation. This paper presents the results of the numerical study that was performed to evaluate the thermal behavior of a metal-concrete CONSTOR RBMK-1500 cask loaded with spent nuclear fuel and placed in an open type interim storage facility which is under fire conditions (steady-state, fire, post-fire). The modelling was performed using the ANSYS Fluent code. Also, a local sensitivity analysis of thermal parameters on temperature variation was performed. The analysis demonstrated that the maximum increase in the fuel load temperatures is about 10 ℃ and 8 ℃ for 30 min 800 ℃ and 60 min 600 ℃ fires respectively. Therefore, during the fire and the post-fire periods, the fuel load temperatures did not exceed the 300 ℃ limiting temperature set for an RBMK SNF cladding for long-term storage. This ensures that fire accident does not cause overheating of fuel rods in a cask.