• Title/Summary/Keyword: Open fracture dislocation of ankle

Search Result 14, Processing Time 0.016 seconds

Clinical Evaluation of the Fracture of Talar Neck (거골 경부 골절에 대한 치료)

  • Rhee, Jin-Hong;Lee, Jeong-Woung;Cho, Jae-Young;Bae, Sang-Won;Lee, Eui-Hyung;Lee, Ju-Youn
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.2
    • /
    • pp.119-125
    • /
    • 1997
  • The fracture and fracture-dislocation of the neck of the talus (Hawkins' type I-IV) are uncommon injuries and represent only 0.12 to 0.32% of all fracures. Authors clinically evaluated in 12 cases Whom treated fracures of the neck of the talus, at department of orthopaedic surgery, Sun General Hospital, from 1990 to 1996, and the following results are obtained. 1. Of 12 cases, there were 11 males and 1 female, average age was 30 years. 2. Causes of fracture was fall down injury in 7 cases(58%), traffic accident in 4 cases(33%), direct trauma in 1 case(8%). 3. According to the classification by Hawkins' type I in 2 cases(17%), type II in 7cases (58%), type III in 3cases(25%). 4. Associated injuries were calcaneal fracture in 3 cases, fracture-dislocation of talus in 3 cases, subtalar dislocation in 3 cases, medial malleolar fracture in 5 cases, soft tissue injury in 3 cases, femur and tibia fracture in 1 case, and lumbar Spine compression fracture in 1 case. 5. Average time to operation after injury was 2.5 days. 6. In 2 cases were treated conservatively and 10 cases were treated open reduction and internal fixation with screw or K-wire. 7. Complications were avascular necrosis in 4 cases, post traumatic arthritis in 2 cases, skin necrosis in 4 cases, and then ankle fusion was done in 2 cases. 8. High rate of complication was seen in the talar neck fracture associated with calcaneal fracture. In the analysis of above results, evaluated by Hawkins' scoring system were excellent to fair in 75%.

  • PDF

Fracture and Dislocation of Lisfranc Joint: Treatment with Screw and Kirschner Wire (리스프랑 관절 골절 및 탈구: 나사와 Kirschner 강선을 이용한 치료)

  • Ha, Dong-Jun;Kim, Jeon-Gyo;Gwak, Heui-Chul;Jang, Yue-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.181-187
    • /
    • 2015
  • Purpose: The purpose of this study is to retrospectively analyze the clinical results of screws and Kirschner wire (K-wire) fixation in patients with fracture dislocation of Lisfranc joint and the consequence of screw breakage. Materials and Methods: Sixty patients underwent Lisfranc joint open reduction and removal of internal fixators from January 2007 to December 2011. Forty-nine cases (81.7%) underwent operations with screw alone, and 11 cases (18.3%) underwent operations with both screws and K-wires. Type of internal fixators, duration of internal fixator removal, breakage of internal fixators and satisfaction with reduction were investigated. Additionally, American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scales were analyzed. Results: The internal fixator was broken in 5 cases (8.3%). The average duration of instrument removal was 154 days in the non-broken screw group and 268.6 days in the broken screw group (p<0.05). The average AOFAS midfoot scale was 77.4 in the non-broken screw group and 74.2 in the broken screw group. The most commonly damaged portion was the first tarsometatarsal (Lisfranc) joint. Conclusion: Treatment with screws and K-wires was effective in patients with fracture dislocation of Lisfranc joint. The appropriate time for screw removal should be considered.

Clinical Observation and Treatment of Fracture-Dislocation of Talus (거골 골절 및 탈구의 임상적 고찰)

  • Lee, Dong-Chul;Kim, Se-Dong;Jung, Hae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.302-311
    • /
    • 1992
  • Talus is a important structure of the ankle joint and its function is critical for ambulation and weight bearing. The talus fracture is rare, but the complications of fracture and dislocation are serious and resulting in avascular necrosis, osteoarthritis. So its treatment is carefully considered at initial status. Authors reviewed 11 cases of fracture and dislocation of the talus treated at Yeungnam university hospital from 1984 to 1991. The longest follow up was 8 years and shortest, 1 year. The results were as follows. 1. There were all males, the average age was 30 years old. 2. The most common cause was fall down(8 cases), and next traffic accident(2cases), sports injury(1 case). 3. According to Marti-Weber classification, 1 cases was type I, 1 in type II, 4 in type III and 5 in type IV. 4. The method of treatment were open reduction and internal fixation in 6 cases, the others were closed reduction in 5 cases. 5. Final results(by Hawkins grading system) were as follows, 3 cases were excellent, 4 cases were good, 1 case was fair and 3 cases were poor. 6. Complications were AVN in 2 cases, degenerative arthritis in 8 cases, malunion in 1 case. 7. The range of motion of the ankle joint was relatively preserved(74%), but in the subtalar joint it was decreased(43%).

  • PDF

Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures (발목 골절 및 탈구 혹은 경골 천정 골절 환자들의 수술에 있어 경종골핀을 이용한 발목 외고정 장치를 적용했을 때의 임상적 효용성)

  • Park, Dae-Hyun;Gwak, Heui-Chul;Kim, Jung-Han;Lee, Chang-Rak;Kwon, Yong-Uk;Choo, Hye-Jung;Park, Chul-Soon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2020
  • Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.