• Title/Summary/Keyword: Open column

Search Result 263, Processing Time 0.02 seconds

Simulation study on dynamic response of precast frames made of recycled aggregate concrete

  • Pham, ThiLoan;Xiao, Jianzhuang;Ding, Tao
    • Computers and Concrete
    • /
    • v.16 no.4
    • /
    • pp.643-667
    • /
    • 2015
  • 3-dimentional precast recycled aggregate concrete (RAC) finite element models were developed by means of the platform OpenSees to implement sophisticated nonlinear model subjected to seismic loads. Efforts were devoted to the dynamic responses (including dynamic characteristics, acceleration amplifications, displacements, story drifts) and capacity curve. In addition, this study extended the prediction on dynamic response of precast RAC model by parametric study of material properties that represent the replacement percentage of recycled coarse aggregate (RCA). Principles and assumptions that represent characteristics of precast structure and influence of the interface between head of column and cast-in-place (CIP) joint on the stiffness of the joints was put forward and validated by test results. The comparison between simulated and tested results of the precast RAC frame shows a good correlation with most of the relative errors about 25% in general. Therefore, the adopted assumptions and the platform OpenSees are a viable approach to simulate the dynamic response of precast frames made of RAC.

Analytical Method of additive in Polyester (I) (폴리에스테르의 첨가제 분석법(I))

  • Jung, Jong Hwa;Lee, Kyeong Hee
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • A method to analyze additives in a polyester resin has been studied by utilizing a centrifuge and a thin layer chromatography. Identification of the separated organic and inorganic compounds were carried out by spectrophotometers, such as NMR, UV-VIS, IR and XRD. For the polyester resin studied in this research contained organic and inorganic compounds which were found to be a dimer form of 2-phenylbenzoazole and an anatase form of $TiO_2$, respectively.

  • PDF

Multi-Pesticide Residue Method for Analysis of Organochlorine and Organophosphorus Pesticide

  • Bonghun Lee;Woo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.37-39
    • /
    • 1997
  • Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N, The final extract was analyzed by gas chromatography with electron-capture detector(GC/ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pesticides were ranged from 60.8 to 84.9% and those of 15 organophosphorus pesticides, from 70.5 to 100.0%(except phosmet and azinphos-methyl). The minimum detectable levels of this analytical method were low (0.021-0.058 mg/kg).

  • PDF

A Study on Capillary Column Ion Chromatography

  • 김호현;표동진
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.05a
    • /
    • pp.115-116
    • /
    • 2001
  • 본 연구에서는 이온 크로마토그래피로 환경오염물질들을 분석하고자 할때의 단전들을 해소하기 위하여 모세관 컬럼 이온 크로마토그래피를 개발하였다. 모세관 컬럼은 두가지 형태로 개발하였는데 하나는 packed capillary 컬럼이며 다른하나는 open tubular capillary 컬럼이다. 또한 위와 같이 모세관 컬럼을 개발하여 사용하게됨을써, 부수적으로 펌프, 시료주입기, 억압장치 그리고 전도도 셀 등을 모두 적은 부피를 다룰 수 있는 구조로 바꾸어 주었다. 따라서 본 연구의 결과로 미량환경오염 물질의 분석에 모세관 컬럼 이온크로마토그래피를 이용할 수 있는 가능성을 확인할 수 있었고, 나아가 이온 크로마토그래피의 소형화로 현장에서 직접 분리, 분석을 할 수 있으리라 기대된다.

  • PDF

Analysis of Molecular Species of Vegetable Oil Triglycerides by Capillary Column GC-MS (Capillary Column GC-MS에 의한 식물유 트리글리세리드 분자종의 분석)

  • Yoon, Hyeung-Sik;Kim, Seon-Bong;Park, Yeung-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.391-398
    • /
    • 1989
  • Triglyceride molecular species In some vegetable oils were analyzed by capillary column gas chromatography and electron impact ionization mass spectrometry utilizing selected ion monitoring. Triglycerides were separated according to their molecular weights and their degrees of unsaturation on $25m{\times}0.25mm$ fused silica open tubular capillary column coated with a phenylmethylsilicone gum stationary phase and in an analysis time less than 13 min. Triglyceride molecular species were identified by analyzing the fragment ions having the same time on the selected ion monitoring profile . The major triglyceride molecular species in each oils were $C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL:18.3%),\;C_{18:2}.\;C_{18:2}.\;C_{18:2}(LLL;\;14.3%),\;C_{18:0}.\;C_{18:2}.\;C_{18:2}(SLL;\;14.1%),\;C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;13.2%),\;C_{16:0}.\;C_{18:2}.\;C_{18:1}(PLO;\;11.6%)$ in corn oil, $C_{18:2}.\;C_{18:2}.\;C_{18:2}(LLL;\;18.0%),\;C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL;\;18.0%),\;C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;17.1%)$ in safflower oil, $C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;23.5%),\;C_{16:0}.\;C_{18:2}.\;C_{18:1}(PLO;\;13.8%),\;C_{18:0}.\;C_{18:1}.\;C_{18:1}(SOO;\;13.5%),\;C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL;\;10.6%)$ in cottonseed oil.

  • PDF

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

Microstructure Characterization of Cu Thin Films : Effects of Sputter Deposition Conditions (스퍼터 증착조건에 따른 구리박막의 미세구조 분석)

  • Joh, Cheol-Ho;Jung, Jin-Goo;Kim, Young-Ho
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.265-274
    • /
    • 1999
  • The microstructure of Cu thin films in various deposition conditions was characterized. Cr films (50 nm thick) and Cu films (500 or 1000 nm thick) were deposited on polyimide films by DC magnetron sputtering. The Ar pressure during Cu deposition was controlled to 5, 50 and 100 mtorr. The microstructure was characterized using conventional and high resolution SEM and TEM. As sputtering pressure increases, open boundaries are observed more frequently. The Cu film deposited at 5 mtorr has a dense and uniform structure, while low-density regions or open boundaries between columns exist in the film deposited at higher pressure. As the film grows thicker, open boundaries are wider and the density of open boundaries are higher. The comparison between SEM and TEM show that the small features shown in high resolution SEM are grains. High resolution SEM is very effective to characterize the microstructure of the thin films. One column in the films deposited at 50 and 100 mtorr consists of several grains, which are smaller than those deposited at 5 mtorr.

  • PDF

Numerical Simulations for Optimal Utilization of Geothermal Energy under Groundwater-bearing Conditions (지하수 부존지역에서 최적 지열에너지 활용방식 수치 모의)

  • Kim, Jin-Sung;Cha, Jang-Hwan;Song, Sung-Ho;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.487-499
    • /
    • 2014
  • While the vertical open type of heat exchanger is more effective in areas of abundant groundwater, and is becoming more widely used, the heat exchanger most commonly used in geothermal heating and cooling systems in Korea is the vertical closed loop type. In this study, we performed numerical simulations of the optimal utilization of geothermal energy based on the hydrogeological and thermal properties to evaluate the efficiency of the vertical open type in areas of abundant groundwater supply. The first simulation indicated that the vertical open type using groundwater directly is more efficient than the vertical closed loop type in areas of abundant groundwater. Furthermore, a doublet system with separated injection and extraction wells was more efficient because the temperature difference (${\Delta}$) between the injection and extraction water generated by heat exchange with the ground is large. In the second simulation, we performed additional numerical simulations of the optimal utilization of geothermal energy that incorporated heat transfer, distance, flow rate, and groundwater hydraulic gradient targeting a single well, SCW (standing column well), and doublet. We present a flow diagram that can be used to select the optimal type of heat exchanger based on these simulation results. The results of this study indicate that it is necessary to examine the adequacy of the geothermal energy utilization system based on the hydrogeological and thermal properties of the area concerned, and also on a review of the COP (coefficient of performance) of the geothermal heating and cooling system.

Antifungal Effect and activity spectrum of crude antifungal proteins from hemolymph of larvae of Tenebrio molitor in Korea (한국산 갈색거저리로부터 분리된 항진균단백질의 항균효과와 그 작용 범위)

  • Chung, Seung-Jo;Lee, Young-Hoon;Chung, Jae-Hoon;Lee, Bok-Ruel;Han, Dong-Min
    • The Korean Journal of Mycology
    • /
    • v.23 no.3 s.74
    • /
    • pp.232-237
    • /
    • 1995
  • Antifungal protein from the hemolymph of larvae of Tenebrio molitor in Korea was partially purified by $C_{18}$ open column chromatography and assayed for the activity spectrum using 3 kinds of yeast and 4 kinds of filamentous fungi. The crude antifungal protein showed static activity for a broad range of fungal species. Weak cidal effects were observed in growing yeast type cells, including Candida and Saccharomyces. The affected cells were changed from ovoid to swollen and spherical form in shape. For filamentous fungi including Aspergillus and Fusarium, the crude antifungal protein affected the spore germination and the hyphal growth but not the viability significantly.

  • PDF

Experimental Study of Shape Parameter of Land-based OWC Wave Energy Converter (고정식 진동 수주형 파력 발전기(OWC) 형상 파라미터의 실험 연구)

  • Koo, Weon-Cheol;Kwon, Jin-Sung;Kim, Jun-Dong;Kim, Sung-Jae;Kim, Min-Woo;Choi, Mun-Kwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.33-38
    • /
    • 2012
  • The aim of this experimental study was to analyze the effect of the shape parameters and chamber pressure of a land-based oscillating water column (OWC) in regular incident waves. The magnitude of the free surface elevations inside the chamber was measured in a two-dimensional wave tank for various chamber skirt drafts and bottom slope angles. The surface elevations were also measured under both open chamber and partially open chamber conditions. From these measurements, the optimum shape of the OWC device could be predicted for the maximum wave energy conversion efficiency. It was found that the resonance frequency of the OWC system associated with incident waves moved toward the long wave region with increments of the draft of the chamber skirt and bottom slope. The behavior of the free surface elevation inside the chamber was also found to be dependent on the chamber pressure.