• Title/Summary/Keyword: Open abdomen

Search Result 30, Processing Time 0.026 seconds

Early Definitive Closure of an Open Abdomen by Using Porcine Dermal Collagen Graft: A Case Report (외상환자의 손상통제 수술 후 돼지진피아교질 이식편을 이용한 조기 완전 폐복의 사례보고)

  • Park, Sung Jin;Kim, Jae Hun;Yun, Sung Pil;Choi, Sun Woo;Kim, Seon Hee
    • Journal of Trauma and Injury
    • /
    • v.26 no.1
    • /
    • pp.14-17
    • /
    • 2013
  • Purpose: The open abdomen is now the standard of care in various clinical situations, especially it is used to treat abdominal compartment syndrome. Many techniques have been reported for closure after an open abdomen, but most take a long time for complete definitive closure and are associated with various problems. We describe a technique using biologic mesh that can achieve early definitive closure after an open abdomen. Methods: A 45-year-old man presented to the emergency room with a painful hip and painful lower extremities after a fall from 80 feet. Radiologic examination revealed multiple fractures of the pelvis and low extremities. Abdominal compartment syndrome caused by a retroperitoneal hematoma developed during the orthopedic surgery. We performed exploration immediately and closed abdomen temporarily. A peritoneal graft of porcine dermal collagen with anterior myofascial approximation of the rectus abdominis muscles and sliding skin flap was performed three days after the previous surgery. Results: There were no complications related to the wound. The patient was transferred to the Department of Orthopedic Surgery seven days after the initial surgery. Conclusion: Early definitive closure using porcine dermal collagen is a feasible method that can reduce the length of hospitalization and the number of operations for an open abdomen.

Enteroatmospheric Fistula Associated with Open Abdomen

  • Gwak, Jihun;Lee, Min A;Ma, Dae Sung;Choi, Kang Kook
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.195-200
    • /
    • 2016
  • Enteroatmospheric fistula (EAF) is one of the most devastating complications in patients with an open abdomen and has associated morbidity and mortality rates. No gold standard therapy has been established for the treatment of EAF, and thus, treatment decision making is dependent on the experience of medical staff. Nevertheless, treatment involves the following; 1) sepsis must be managed, 2) sufficient nutritional support must be provided, and 3) effluent must be isolated from skin and open viscera. Here the authors present the case of a 29-year-old man who developed enteroatmospheric fistula after damage control laparotomy.

Successful treatment of a bowel fistula in the open abdomen by perforator flaps and an aponeurosis plug

  • Sashida, Yasunori;Kayo, Munefumi;Hachiman, Hironobu;Hori, Kazuki;Kanda, Yukihiro;Nagoya, Akihiro
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.375-378
    • /
    • 2018
  • In this report, we present a case of successful treatment of a bowel fistula in the open abdomen by perforator flaps and an aponeurosis plug. A 70-year-old man underwent total gastrectomy and developed anastomotic leakage and dehiscence of the abdominal wound a week later. He was dependent upon extracorporeal membrane oxygenation, continuous hemodiafiltration, and a respirator. Bowel fluids contaminated the open abdomen. Two months after the gastric operation, a plastic surgery team, in consultation with general surgeons, performed perforator flaps on both sides and constructed, as it were, a bridge of skin sealing the orifice of the fistula. The aponeurosis of the external oblique muscle was elevated with the flap to be used as a plug. The perforators of the flaps were identified on preoperative and intraoperative ultrasonography. This modality allowed us to locate the perforators precisely and to evaluate the perforators by assessing their diameters and performing a waveform analysis. The contamination decreased dramatically afterwards. The bare areas were gradually covered by skin grafts. The fistula was closed completely 18 days after the perforator flap. An ultrasound-guided perforator flap with an aponeurosis plug can be an option for patients suffering from an open abdomen with a bowel fistula.

Feasibility of Early Definitive Internal Fixation of Pelvic Bone Fractures in Therapeutic Open Abdomen

  • Choi, Kyunghak;Jung, Kwang-Hwan;Keum, Min Ae;Kim, Sungjeep;Kim, Jihoon T;Kyoung, Kyu-Hyouck
    • Journal of Trauma and Injury
    • /
    • v.33 no.1
    • /
    • pp.18-22
    • /
    • 2020
  • Purpose: Damage control laparotomy has contributed to improved survival rates for severe abdominal injuries. A large part of severe abdominal injury occurs with a concomitant pelvic bone fracture. The safety and effectiveness of internal fixation of pelvic bone fracture(s) has not been established. The aim of the present study was to evaluate infection risk in the pelvic surgical site in patients who underwent emergent abdominal surgery. Methods: This single-center retrospective observational study was based on data collected from a prospectively maintained registry between January 2015 and June 2019. Patients who underwent laparotomy and pelvic internal fixation were included. Individuals <18 and ≥80 years of age, those with no microbiological investigations, and those who underwent one-stage abdominal surgery were excluded. Comprehensive statistical comparative analysis was not performed due to the small number of enrolled patients. Results: A total of six patients met the inclusion criteria, and the most common injury mechanism was anterior-posterior compression (67%). The average duration of open abdomen was 98 hours (range, 44-98), and the time interval between abdominal closure and pelvic surgery was 98 hours. One patient (16.7%) died due to multi-organ dysfunction syndrome. Micro-organisms were identified in the abdominal surgical site in five patients (83%), with no micro-organisms in pelvic surgical sites. There was no unplanned implant removal. Conclusions: Internal fixation of pelvic bone fracture(s) could be performed in the state of open abdomen, and the advantages of early fixation may countervail the risks for cross contamination.

Abdominal Wall Closure Using Artificial Mesh for Patients with an Open Abdomen (복부개방(Open abdomen) 환자에서 인공막(Artificial Mesh)를 이용한 근막봉합술)

  • Cha, Sung Whan;Shim, Hong Jin;Jang, Ji Young;Lee, Jae Gil
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.172-177
    • /
    • 2012
  • Purpose: After damage control surgery, abdominal wall closure may be impossible due to increased intra-abdominal pressure (IAP), and primary closure may induce abdominal compartment syndrome. The purpose of this study was to investigate changes in the IAP and the feasibility of abdominal wall closure using artificial mesh. Methods: From July 2010 to July 2011, 8 patients with intra-abdominal hypertension underwent abdominal wall closure using artificial mesh. Medical data such as demographics, diagnosis, operation, IAP, postoperative complications, mortality and length of hospital stays were collected and reviewed, retrospectively. One patient was excluded because of inadequate measurement of the IAP. Results: Seven patients, 4 males and 3 females, were enrolled, and the mean age was 54.1 years old. Causes of operations were six traumatic abdominal injuries and one intra-abdominal infection. The IAP was reduced from $21.9{\pm}6.6mmHg$ before opening the abdomen to $15.1{\pm}7.1mmHg$ after fascial closure. Fascial closure was done on $14.9{\pm}17.5$ days after the first operation. The mean lengths of the hospital and the intensive care unit (ICU) stays were 49.6 days and 29.7 days respectively. Operations were performed $3.1{\pm}1.5$ times in all patients. Two patients expired, and one was transferred in a moribund state. Three patients suffered from complications, such as retroperitoneal abscesses, enterocutaneous fistulas, and bleeding that was related to the negative pressure wound therapy. Conclusion: After abdominal wall closure using artificial mesh, intra-abdominal pressure was well controlled, and abdominal compartment syndrome does not occur. When the abdominal wall in patients who have intra-abdominal hypertension is closed, artificial mesh may be useful for maintaining a lower abdominal pressure. However, when negative pressure wound therapy is used, the possibility of serious complications must be kept in mind.

Will Middle-Aged Korean Women Buy Jeans Again?

  • Kang, Won Sook;Kwon, Yoo Jin
    • International Journal of Costume and Fashion
    • /
    • v.15 no.2
    • /
    • pp.49-62
    • /
    • 2015
  • The purpose of the study was to investigate jean consumption among middle-aged Korean women and the characteristics of consumers as potential jean consumers. The data were collected from the survey of 238 Korean women aged 45 to 64 years old. The respondents prefer outlet store to other retail outlets and wear jeans mainly for travel, grocery shopping, and outing. The main reason for not wearing jeans is body change, which leads to poor fit in abdomen and waist area. The sample was clustered into two groups based on interest in jeans: high-interest and low-interest group. From the examination of group differences, the high-interest group rated conformity/brand reputation, scarcity, and attractiveness of appearance significantly higher compared to the low-interest group among the five clothing benefits pursued. No difference was found in obesity and body satisfaction. Group differences were found in recent purchase, price, number of jeans owned, and frequency of wearing jeans. The results suggest the characteristics of the potential jean market among middle-aged women in Korea. Implications are discussed.

Sodium Carboxymethylcellulose and Hyaluronic Acid on Prevention of Intra-abdominal Adhesion in Rats (Rat에서 Sodium Carboxymethylcellulose와 Hyaluronic acid의 복강 내 유착 예방)

  • 한태성;이주명;윤영민;강태영;신태균;강윤호;김남중;김희석;이경갑
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.323-327
    • /
    • 2003
  • This study has been conducted to compare the efficacy of sodium carboxymethylcellulose (SCMC) and hyaluronic acid (HA) on prevention of adhesion after artificial wound was induced in intestine. 1 % SCMC and 0.3% HA solution and saline solution were respectively administered to abdominal cavity. Each of the three groups consists of 11 rats. The abdominal cavity of each rat was coated with 2 ml of the allocated solution just after the abdomen was cut open, and it was coated with each solution of 1 ml before abrasion were caused on the cecum, the ascending colon and the transverse colon. Then, an additional 1 ml solution was injected before the abdomen was closed. On day 14 after the operation, each adhesion formation was evaluated at the score of 0-4. The HA group and SCMC group showed significantly lower adhesion scores than control group in all regions(P< 0.05). The adhesion scores of ascending colon, transverse colon and no abrasion region of the viscera showed little difference between HA group and SCMC group(P< 0.05), but the effect of adhesion reduction showed higher tendency in the HA group than the SCMC. The adhesion score of the cecum was significantly lower in HA group than SCMC group(P< 0.05). In conclusion, the SCMC solution and HA solution were effective on prevention of abdominal adhesion resulting from the celiotomy. Among of them, the HA solution could be more effective on prevention of adhesion than SCMC solution.

Management of Thoracic Aortic Injury after Blunt Trauma: Nine Cases at a Single Medical Center

  • Lee, Kyungwon;Lee, Jae Gil
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.146-150
    • /
    • 2016
  • Purpose: Traumatic aortic injuries are rare, but life threatening condition. They usually occur after high velocity impact on the chest or abdomen such as traffic accident or fall. We report the experiences of the traumatic aortic injuries at a single center. Methods: We retrospectively reviewed the medical records of nine patients with aortic injury resulting from the blunt trauma from Jan. 2010 to May. 2016. Results: The mean age was $51.1{\pm}20.8$ years old, and ten (90.9%) were men. The mechanisms of injury were traffic accidents in seven patients (motorcycle accidents; 3, car accidents; 4), and four in fall injury. Most common injured sites were thoracic aorta (9, 81.8%). Aortic injuries were repaired by endovascular approach in four patients, and by open graft surgery in four. Two patients were managed conservatively. Nine patients survived without any complications. Conclusion: We had experienced different approaches for management of aortic injuries after blunt trauma according to locations and severity of lesions.

Postoperative Systemic Dissemination of Injected Elemental Mercury

  • Kang, Suk-Hyung;Park, Seung-Won;Moon, Kyung-Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.245-247
    • /
    • 2011
  • There were only a few reports of mercury on pulmonary artery. However, there is no data on surgery related mercury dissemination. The objective of the present article is to describe one case of postoperative injected mercury dissemination. A 19-year-old man presented severe neck pain including meningeal irritation sign and abdominal pain after injection of mercury for the purpose of suicide. Radiologic study showed injected mercury in the neck involving high cervical epidural space and subcutaneous layer of abdomen. Partial hemilaminectomy and open mercury evacuation of spinal canal was performed. For the removal of abdominal subcutaneous mercury, C-arm guided needle aspiration was done. After surgery, radiologic study showed disseminated mercury in the lung, heart, skull base and low spinal canal. Neck pain and abdominal pain were improved after surgery. During 1 month after surgery, there was no symptom of mercury intoxication except increased mercury concentration of urine, blood and hair. We assumed the bone work during surgery might have caused mercury dissemination. Therefore, we recommend minimal invasive surgical technique for removal of injected mercury. If open exposures are needed, cautious surgical technique to prohibit mercury dissemination is necessary and normal barrier should be protected to prevent the migration of mercury.