• 제목/요약/키워드: Open Loop Test

검색결과 96건 처리시간 0.033초

개루프 제어의 실린더 진동형 자이로 구현 및 실험 (The Implementation and Experiments of Open-Loop Cylindrical Vibratory Gyroscope)

  • 공형직;김정엽;홍성경
    • 제어로봇시스템학회논문지
    • /
    • 제10권8호
    • /
    • pp.669-672
    • /
    • 2004
  • This paper considers the implementation and experiments of an open-loop Cylindrical Vibratory Gyroscope(CGV). An open-loop CGV composed of thin cylindrical vibrating element, electromagnetic drive and pick-off element with open-loop control was designed and fabricated. The experimental performance tests of the open-loop CGV were done using a temperature chambered rate table. Also, the limitations of open-loop CGV were analyzed and the solution for the limitations was proposed.

터보펌프+가스발생기 개회로 연계시험 (Turbopump+Gas generator Open-loop coupled test)

  • 김승한;남창호;김철웅;문윤완;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.125-128
    • /
    • 2008
  • 30톤급 액체산소-케로신 액체로켓엔진 개발의 중간 단계로서 연소기를 제외한 터보펌프 등의 엔진 주요 구성품을 이용한 터보펌프+가스발생기 개회로 연계시험이 수행되었다. 터보펌프+가스발생기 개회로 연계시험의 시험기 구성 및 시험결과를 제시하였다. 연소기를 오리피스로 모사하는 상태에서의 터보펌프+가스발생기 개회로 연계시험기의 예냉, 시동기를 이용한 시동 및 가스발생기 점화, 터보펌프 정격 구동이 성공적으로 수행되었다. 개회로 연계시험 결과는 터보펌프+가스발생기 폐회로 연계시험 수행을 위해 활용되었다.

  • PDF

터보펌프-가스발생기 개회로 연계시험 연구 (Study on Turbopump-Gas Generator Open-Loop Coupled Test)

  • 김승한;남창호;김철웅;문윤완;설우석
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.563-568
    • /
    • 2010
  • 30톤급 액체산소/케로신 액체로켓엔진개발의 중간단계로 터보펌프-가스발생기 개회로 연계시험이 수행되었다. 터보펌프-가스발생기 개회로 연계시험은 엔진시스템 작동 모사 환경 시험으로서 가스발생기로의 추진제는 터보펌프 출구를 통해 공급되지만, 가스발생기 출구 가스는 터빈 구동에 이용되지 않고 외부로 배출된다. 터보펌프-가스발생기 개회로 연계시험 목적, 시험설비 구성, 제어시스템의 작동 조건, 시험 수행 절차, 연계시험기의 구성 형태, 개회로 연계시험 결과가 제시되었다. 터보펌프-가스발생기 개회로 연계시험 결과, 연계시험기의 예냉 절차와 시동 특성, 정격 작동성 및 안정적인 종료 특성이 액체로켓 엔진시스템 작동 환경 모사 조건에서 확인되었다.

터보펌프 조립체-가스발생기 연계 개회로 시험에서의 시동특성 분석 (Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Open Loop Test)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.15-18
    • /
    • 2008
  • 본 연구에서는 터보펌프 조립체-가스발생기 연계시험 중 개회로 시험에 대한 시동 특성을 분석하였고 수치적으로 해석하였다. 시험에서 터빈의 시동 및 구동은 수소 기체로 수행하였고 그에 따른 가스발생기 점화 및 연소압의 발달을 살펴보았고 해석도 동일한 조건으로 수행하여 결과를 비교하였다. 회전수의 발달 특성은 시험과 잘 일치하는 것을 볼 수 있었고 가스발생기 연소압 발달 특성의 경우 정성적인 기울기가 일치하는 것을 볼 수 있었다.

  • PDF

기체 탄화수소 연료 연소시험에서 연소불안정의 개루프 제어 (Open-Loop Control of Combustion Instability in Hot-Firing Test Using Gaseous Hydrocarbon Fuel)

  • 황동현;안규복
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.28-36
    • /
    • 2018
  • 기체 탄화수소 연료를 사용하는 덤프 연소기의 연소불안정에 개루프 제어를 적용하는 연구를 수행하였다. 연료들의 특성화학시간이 유사한 연소조건에서 음향 발생기를 이용하여 제어 출력과 주파수를 변화시켰다. 연소불안정 주파수와 동일한 주파수의 개루프 제어에서는 음향 발생기의 출력이 제어성능에 영향을 주었다. 연소불안정 주파수와 다른 주파수의 개루프 제어결과로부터 개루프 제어주파수는 연소불안정 주파수와 유사하게 설정하는 것이 효과적임을 알 수 있었다.

Simple and Flexible Temperature Control System for Space Environment Test

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.29.1-29.1
    • /
    • 2008
  • The temperature control system which is using liquid and gaseous nitrogen has been known as the most economical system to simulate space temperature condition due to relatively not expansive price of the liquid nitrogen (less than 0.2 USD per liter). And, among these systems, the closed loop system which circulates compressed nitrogen gas come from sprayed liquid nitrogen by blower and makes a target temperature with heat from an electrical heater and flow rate of liquid nitrogen is prevail all over the world. But, this complete closed loop system requires expansive equipments such as blower, heater, and liquid nitrogen injector, and special maintenance on the system. Therefore, KARI is developing efficient and simple open loop system which utilizes liquid and gaseous nitrogen with eliminating a special blower and other expansive units. In this study, this open loop system with more efficiency and flexibility will be designed and introduced.

  • PDF

토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의 (Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model)

  • 이성순;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

Performance Comparison of Three Different Types of Attitude Control Systems of the Quad-Rotor UAV to Perform Flip Maneuver

  • Lee, Byung-Yoon;Yoo, Dong-Wan;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.58-66
    • /
    • 2013
  • This paper addresses the performance of three different types of attitude control systems for the Quad-rotor UAV to perform the flip maneuver. For this purpose, Quad-rotor UAV's 6-DOF dynamic model is derived, and it was used for designing an attitude controller of the Quad-rotor UAV. Attitude controllers are designed by three different methods. One is the open-loop control system design, another is the PD control system design, and the last method is the sliding mode control system design. Performances of all controllers are tested by 6-DOF simulation. In case of the open-loop control system, control inputs are calculated by the quad-rotor dynamic model and thrust system model that are identified by the thrust test. The 6-DOF realtime simulation environment was constructed in order to verify the performances of attitude controllers.

역물류를 고려한 통합물류망에서의 입지:경로문제 (A Location-Routing Problem for Logistics Network Integrating Forward and Reverse Flow)

  • 나호영;이상헌
    • 산업공학
    • /
    • 제22권2호
    • /
    • pp.153-164
    • /
    • 2009
  • An effective management for reverse flows of products such as reuse, repair and disposal, has become an important issue for every aspect of business. In this paper, we study the Location-Routing Problem (LRP) in the multi-stage closed-loop supply chain network. The closed-loop supply chain in this study integrated both forward and reverse flows. In forward flow, a factory, Distribution Center (DC) and retailer are considered as usual. Additionally in reverse flow, we consider the Central Returns collection Center (CRC) and disposal facility. We propose a mixed integer programming model for the design of closed-loop supply chain integrating both forward and reverse flows. Since the LRP belongs to an NP-hard problem, we suggest a heuristic algorithm based on genetic algorithm. For some test problems, we found the optimal locations and routes by changing the numbers of retailers and facility candidates. Furthermore, we compare the efficiencies between open-loop and closed-loop supply chain networks. The results show that the closed-loop design is better than the open one in respect to the total routing distance and cost. This phenomenon enlarges the cut down effect on cost as an experimental space become larger.

루프이음을 가진 모듈식 슬래브 연결부의 휨성능에 관한 실험적 연구 (An Experimental Study on the Flexural Performance of Modular Slab Connections with Loop Joints)

  • 김동완;신정열
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.459-467
    • /
    • 2016
  • 최근, 도로를 따라 지하 5~7m의 저심도에 설치되는 저심도 도시철도시스템의 경제성을 확보하기 위해, 신개념의 모듈식 개착 시공법을 개발 중에 있다. 본 연구에서는 상부 슬래브간의 연결부에 대한 구조성능 검증을 위해 루프이음을 가진 프리캐스트 철근콘크리트 부재들의 4점 재하 실험을 수행하였다. 전체 11개의 실험체가 제작되었으며 단면형상, 이음부 형상, 이음길이, 횡방향 보강철근을 변수로 이음이 없는 전단면 및 반단면 실험체와 비교하였다. 실험결과, 루프이음 실험체는 항복하중과 최대하중시 변위량 차이가 컸으며 이는 항복이후 접합부에서 발생한 균열이 확장됨에 따라 강성저하로 변위량이 급격히 증가한 것으로 판단된다. 또한 200mm의 루프이음을 가진 반단면 실험체의 경우, 이음이 없는 기준 실험체에 상당하는 휨성능을 확보하며 200mm 초과시 휨성능 향상의 정체기를 보였다.