• 제목/요약/키워드: Opc

Search Result 970, Processing Time 0.024 seconds

Compensation Characteristics or Distorted WDM Channel dependence on Variation of Fiber Dispersion (광섬유 분산 변동에 따른 왜곡된 WDM 채널의 보상 특성)

  • Lee, Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.719-726
    • /
    • 2004
  • In this paper, compensation characteristics of distorted WDM channel due to both chromatic dispersion and self phase modulation (SPM) is numerically investigated under the assumptions of non-uniformly distributed fiber dispersion, in order to inspect the application of mid-span spectral inversion (MSSI) to any exact transmission links. The MSSI is compensation method used in this approach. This method has an optical phase conjugator (OPC) placed in mid-way of total transmission length to compensate distorted WDM channels. It is confirmed that MSSI will become applicable to long-haul WDM systems by controlling input light power of transmission channels, when the averaged dispersion of both fiber sections with respect OPC was varied and distributed unequally each other. Applying MSSI to long-haul WDM system, it is possible to remove all in-line compensator, consequently it will be expected to reducing system cost.

Design of HMI software Interoperable with OPC-DA Server (OPC Server와 연동되는 HMI 소프트웨어 설계)

  • Cha, Jae-Pil;Jang, Dong-Wook;Jo, Sang-Hyun;Sun, Bok-Keun;Kim, Su-Hee;Han, Kwang-Rok
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.801-802
    • /
    • 2006
  • The present study purposes to develop HMI software that runs on Windows CE .NET platform without being bound to specific HMI equipment and accesses data in PLC equipment through interoperation with an OPC-DA server. As the OPC-DA server reads data in PLC equipment, HMI system does not need to be configured differently for different equipments. In addition, when the interface environment of specific equipment changes, it does not require the application of new equipment or the change of communication protocol. As HMI system runs on Windows CE .NET platform, it can be configured using common embedded devices based on Windows CE .NET platform. HMI software reads data in PLC equipment through RS-232C communication interface. In addition, because it connects to an OPC-DA server through Ethernet communication interface, it can access data in PLC equipment as long as Ethernet is usable.

  • PDF

The Compensation Effect of the Distorted WDM Signals Depending upon the Deviation of Residual Dispersion per Span (RDPS) in Dispersion-Managed Optical Transmission Links with the Specially Artificial Distributions of SMF Lengths and RDPS (SMF 길이와 RDPS가 특정하게 인위적으로 분포하는 분산 제어 링크에서 RDPS 편차에 따른 왜곡된 WDM 신호의 보상 효과)

  • Lee, Seong-Real
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.964-966
    • /
    • 2015
  • The effect of the deviations of single mode fiber lengths and residual dispersion per span (RDPS) on the compensation for the distorted WDM signals in the dispersion-managed optical links with the specially artificial distributions of the lengths of SMFs and RDPSs. The considered artificial distribution is following; the lengths of SMF and RDPSs between the adjacent fiber span are more descended in the half transmission section from transmitter to optical phase conjugator (OPC), and those are more ascended in the rest half transmission section from OPC to the receiver, as number of fiber spans are more increased.

  • PDF

Peat stabilization using cement, polypropylene and steel fibres

  • Kalantari, Behzad;Prasad, Arun;Huat, Bujang B.K.
    • Geomechanics and Engineering
    • /
    • v.2 no.4
    • /
    • pp.321-335
    • /
    • 2010
  • This article describes a laboratory research on stabilizing tropical peat using ordinary Portland cement (OPC) as a binding agent, and polypropylene and steel fibres as chemically inert additives. California bearing ratio (CBR) and unconfined compressive strength (UCS) tests were carried out to evaluate the increase in the strength of the stabilized samples compacted at their optimum moisture contents and air cured for up to 90 days. The results show that the UCS values of stabilized peat samples increased by as high as 748.8% by using OPC (5%), polypropylene fibres (0.15%), and steel fibres (2%). The CBR values of the samples stabilized with OPC (5%), polypropylene fibres (0.15%), and steel fibres (4%) showed an increase of as high as 122.7%. The stabilized samples showed a shrinkage in volume upon air curing and this shrinkage was measured by an index called, volume shrinkage index (VSI). The highest VSI recorded was 36.19% for peat without any additives; and the minimum was 0% for the sample containing 30% OPC, 0.15% polypropylene fibres and 2% steel fibres. The technique of stabilizing peat with OPC, polypropylene and fibres, coupled with air curing, appears to be cost-effective compared with other frequently used techniques.

A Study of Response Characteristics and False Counts in Optical Particle Counter (광학 입자 계수기의 응답특성 및 오계수에 관한 연구)

  • 안강호;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.547-554
    • /
    • 1992
  • Response characteristics and false counts of laser and white light optical particle counters (OPC) have been studied as a function of particle size using monodisperse polystylen laterx (PSL) particles. Theoretical light scattering calculations for He-Ne laser based counter have been compared with the experimental results and thus good agreements have been found. The light scattering intensity in monochromatic light shows an oscillatory character for the transparent and spherical particles of PSL due to Mie resonance. Because of this effect, the response of the LAS-X OPC showed almost same responses in the diameter ranges of 0.4mu.m to 0.6mu.m and 0.7mu.m to 1.0mu.m for PSL particles. A laser optical particle counter with high flow rate applied for clean room has been studied to identify the noise sources. Three different manufacturer's clean room optical particle counters alos have been tested to measure the background noise level.

Durability performance of concrete containing Saudi natural pozzolans as supplementary cementitious material

  • Al-Amoudi, Omar S. Baghabra;Ahmad, Shamsad;Khan, Saad M.S.;Maslehuddin, Mohammed
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2019
  • This paper reports an experimental investigation conducted to evaluate the durability performance of concrete mixtures prepared utilizing blends of Type I Portland cement (OPC) and natural pozzolans (NPs) obtained from three different sources in Saudi Arabia. The control concrete mixture containing OPC alone as the binder and three concrete mixtures incorporating NPs were prepared keeping water/binder ratio of 0.4 (by weight), binder content of $370kg/m^3$, and fine/total aggregate ratio of 0.38 (by weight) invariant. The compressive strength and durability properties that included depth of water penetration, depth of carbonation, chloride diffusion coefficient, and resistance to reinforcement corrosion and sulfate attack were determined. Results of this study indicate that at all ages, the compressive strength of NP-admixed concrete mixtures was slightly less than that of the concrete containing OPC alone. However, the concrete mixtures containing NP exhibited lower depth of water penetration and chloride diffusion coefficient and more resistance to reinforcement corrosion and sulfate attack as compared to OPC. NP-admixed concrete showed relatively more depth of carbonation than OPC when subjected to accelerated carbonation. The results of this investigation indicates the viability of utilizing of Saudi natural pozzolans for improving the durability characteristics of concrete subjected to chloride and sulfate exposures.

Alkali-activated GGBS and enzyme on the swelling properties of sulfate bearing soil

  • Thomas, Ansu;Tripathia, R.K.;Yadu, L.K.
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • Use of cement in stabilizing the sulfate-bearing clay soils forms ettringite/ thaumasite in the presence of moisture leads to excessive swelling and causes damages to structures built on them. The development and use of non-traditional stabilisers such as alkali activated ground granulated blast-furnace slag (AGGBS) and enzyme for soil stabilisation is recommended because of its lower cost and the non detrimental effects on the environment. The objective of the study is to investigate the effectiveness of AGGBS and enzyme on improving the volume change properties of sulfate bearing soil as compared to ordinary Portland cement (OPC). The soil for present study has been collected from Tilda, Chhattisgarh, India and 5000 ppm of sodium sulfate has been added. Various dosages of the selected stabilizers have been used and the effect on plasticity index, differential swell index and swelling pressure has been evaluated. XRD, SEM and EDX were also done on the untreated and treated soil for identifying the mineralogical and microstructural changes. The tests results show that the AGGBS and enzyme treated soil reduces swelling and plasticity characteristics whereas OPC treated soil shows an increase in swelling behaviour. It is observed that the swell pressure of the OPC-treated sulfate bearing soil became 1.5 times higher than that of the OPC treated non-sulfate soil.

Applicability of Optical Particle Counters for Measurement of Airborne Pesticide Spray Drift (공기 중 농약 비산의 측정을 위한 광학 입자 측정기의 적용성 평가)

  • Kim, Rack-Woo;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.79-87
    • /
    • 2019
  • With desires for safe food, there is growing concern that pesticide spray drift will expose people, plants, and the environment to pesticide residue and potential negative effects thereof. For highly efficient, safe spray application, technologies for measuring the spray drift should be developed and improved with some urgency. This study investigated the applicability of two optical particle counters (OPCs), which are mostly used to measure airborne particle mass concentration, for measurement of airborne pesticide spray drift. Experiments were conducted in a controlled laboratory and an ash tree orchard to evaluate the handiness and accuracy of two OPCs, OPC 1 and OPC 2. The experimental results indicated that the OPC 1 was better applicable to the measurement of spray drift in the field while the use of the OPC 2 was limited due to its narrow range of measurable droplet sizes. The readings of the OPC 1 produced highly accurate results ($R^2=0.9637$) compared to the actual spray drift. For better application of OPCs, this study suggests the OPCs should be positioned properly to inhale spray droplets of the appropriate size and concentration.

Physical and Waterproof Properties of Mortar Using Cement Sludge Treated with Hydrofluosilicic Acid (규불화수소산 처리 시멘트 슬러지를 사용한 모르타르의 물성 및 방수 특성)

  • 김승문;이병기;김도수;노재성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.76-81
    • /
    • 1998
  • The physical properties of cement sludge treated with hydrofluosilicic acid were investigated. The compressive strength of cement mortar substituted cement sludge was decreased than that of OPC(ordinary portland cement) mortar. Cement sludge, for improving its physical properties, was treated with hydrofluosilicic acid. And compressive strength of cement mortar substituted TCS was greatly improved than that of OPC mortar. Particularly, cement mortar substituted TCS had the higher value in water-proofness than of OPC.

  • PDF

The characteristics of Low Blaine Cement (저 분말도 포틀랜드 시멘트의 특성)

  • 김재영;전준영;송종택
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.13-18
    • /
    • 1998
  • This experiments carried out in order to investigate decreasing of the hydration heat and physical characteristics of the low blaine OPC. The experiments results indicated hydration heat was reduced by about 15% in th low blaine OPC(2300$\textrm{cm}^2$/g). The Mini-slump value of the cement paste was significantly increased and viscosity of one was decreased as blaine value in OPC decrease.

  • PDF