• Title/Summary/Keyword: Online Digital Materials

Search Result 42, Processing Time 0.016 seconds

Survey of elementary school teachers' perceptions of the 2022 revised mathematics curriculum (2022 개정 수학과 교육과정에 대한 초등학교 교사들의 인식 조사)

  • Kwon, Jeom-rae
    • Education of Primary School Mathematics
    • /
    • v.27 no.2
    • /
    • pp.111-137
    • /
    • 2024
  • The purpose of this study is to identify the expected difficulties and necessary support when applying the 2022 revised mathematics curriculum to elementary schools, and to support the establishment of the field. To this end, we explored the major changes in the 2022 revised mathematics curriculum, and based on this, we conducted a survey of elementary school teachers to identify the expected difficulties and necessary support when applying it in the field. In particular, when analyzing the results, we also examined whether there were any differences in the expected difficulties and necessary support depending on the size of the school where it is located and the teaching experience of the teacher. The research results are as follows. First, the proportion of teachers who expect difficulties in applying the 2022 revised mathematics curriculum was mostly below 50%, but the proportion of teachers who demand support was much higher, at around 80%. Second, the difficulty of elementary school teachers in applying the 2022 revised mathematics curriculum was found to be the greatest in evaluation. Third, in relation to the use of edutech, teachers in elementary schools are also expected to have difficulties in teaching and learning methods to foster students' digital literacy, assessment using teaching materials or engineering tools, and assessment in online environments. Fourth, the difficulty of elementary school teachers in applying the 2022 revised mathematics curriculum was also significant in relation to mathematics subject competencies. Fifth, it was found that there is also difficulty in understanding the major changes of the achievement standards, including the addition, deletion, and adjustment of the achievement standards, and the impact on the learning of other achievement standards. Finally, the responses of elementary school teachers to the expected difficulties and necessary support in applying the 2022 revised mathematics curriculum did not differ depending on the size of the school where it is located, but statistically significant differences were found in a number of items depending on the teaching experience of the teacher. Based on these research results, we hope that various support will be provided for the 2022 revised mathematics curriculum, which will be applied annually from 2024.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.