• Title/Summary/Keyword: One-System

Search Result 37,306, Processing Time 0.056 seconds

Users' Behavior Study for the Planning of One-room System Houses (원룸시스템 주택 계획을 위한 거주자 행태연구)

  • 조성희;권미지
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.165-174
    • /
    • 2003
  • The demand for one-room system house as a new type of house will increase gradually, and residents also tend to be diversified. However, a method of planning of planning of one-room system house was limited and unified. Current floor plans of the one-room don't utilize a benefit of open plan in small areas. The purpose of this study is to propose several guidelines for the planning of one-room system houses that correspond to residents' needs in order to facilitate the benefit of open plan such as efficiency and multi-purpose use in small area. For this, a field survey was carried out as case studies, with individual interviews, questionnaires, and actual survey including taking pictures. Subjects were 50 residents who living in one-room system houses in Busan. Space usage behavior of residents, residential satisfactions, and preference attitudes on the attached service facilities were analyzed. The results were synthesized to suggest several guidelines for planning of one-room system house.

Effects of a One-Way Clutch on the Nonlinear Dynamic Behavior of Spur Gear Pairs under Periodic Excitation

  • Cheon Gill-Jeong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.941-949
    • /
    • 2006
  • Nonlinear behavior analysis was used to verify whether a one-way clutch is effective for reducing the torsional vibration of a paired spur gear system under periodic excitation. The dynamic responses were studied over a wide frequency range by speed sweeping to check the nonlinear behavior using numerical integration. The gear system with a one-way clutch showed typical nonlinear behavior. The oscillating component of the dynamic transmission error was reduced over the entire frequency range compared to a system without a one-way clutch. The one-way clutch also eliminated unsteady continuous jump phenomena over multiple solution bands, and prevented double-side contact, even with very small backlash. Installing a one-way clutch on both sides of the gear system was more effective at mitigating the negative effects of external periodic excitation and various parameter changes than a conventional gear system without a one-way clutch.

A Design of an Intelligent Specialized Customer Module based on One to One Marketing (일대일 마켓팅 기반의 지능형 고객 특화 모듈의 설계)

  • 나윤지;한군희
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.108-113
    • /
    • 2004
  • Various studies to increase customer satisfaction of a web based system are performed actively. Also in recent days an interest about the one-on-one marketing that supporting a customer viewpoint service was raised. The study that supporting the one-on-one marketing is required in a web based system. In this study, We designed the intelligent specialized customer module which supporting one-on-one marketing. The proposed system used a data mining technique as a target selling, a cross selling, and upselling so that supporting one-on-one marketing. Also, In experiment on prototype, we show a proposed system was usable in an actual Web base system applying the mining result based on the specialized customer module.

  • PDF

A STUDY ON THE FORMATION OF SHEAR BONDING STRENGTH AND HYBRID LAYER ACCORDING TO THE APPLICATION TIME AND FREQUENCY OF AN ALL-IN-ONE SYSTEM IN PRIMARY TEETH. (유치에서 All-In-One system의 적용 시간과 적용 횟수에 따른 전단 결합 강도 및 혼성층 형성에 관한 연구)

  • Hong, Sang-Jin;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.263-271
    • /
    • 2003
  • The purpose of the present study was to evaluate the patterns of hybrid layer according to the application time and the frequency and its effects on the shear bonding strength of All-In-One system in primary teeth. A single bonding agent(Scotchbond Multi-Purpose Plus, 3M) and an All-In-One system(Prompt L-pop, 3M ESPE) were applied on the dentin varying the application time and the frequency in primary teeth. Shear bond strength was measured and the patterns of hybrid layers were observed by SEM. The following results were obtained ; 1. The shear bonding strength of single bonding agent was significantly higher than that of All-In-One system(P<0.05). 2. The shear bonding strength of All-In-One system applied twice or 3 times were higher than that of applied once (P<0.05). And thickness of the hybrid layer was increased when applied twice or 3 times compared to once. 3. The shear bonding strength of All-In-One system when applied for 15 second and 30 second were higher than that of 7 second (P<0.05). And the hybrid layer thickness of 15 second and 30 second's application time were higher than that of 7 second. 4. Thickness of hybrid layer applied with single bonding agent was $2-4{\mu}m$ and that of All-In-One system was $1-2{\mu}m$.

  • PDF

Reliability Analysis for One-Shot Systems with Periodic Inspection (주기적 검사가 실시되는 원샷 시스템의 신뢰도 분석)

  • Kim, Ha Won;Yun, Won Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.1
    • /
    • pp.20-29
    • /
    • 2016
  • This paper considers one-shot systems such as missiles, air bags of automobiles that are stored for a long time and are used at most once. One shot systems are inspected periodically to detect system failures and repair the system because we do not know whether the system will work or not on demand. Thus, we can keep high availability of the system by periodic inspection. Martinez (1984) obtained the system reliability approximately. In this paper, we obtain the exact system reliability under periodic inspection. Finally, we compare the system reliability from our formula with one of Martinez (1984) by numerical examples.

A research on an efficient methodology for conversion from Verilog to SystemC (Verilog에서 SystemC로 변환을 위한 효율적인 방법론 연구)

  • 신윤수;고광철;정제명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1177-1180
    • /
    • 2003
  • Recently, SystemC is one among the language observed. In Industry, there are many the languages that use Verilog. But, unskillful SystemC users must learn SystemC for conversion that from Verilog to SystemC and need time and effort for this. By these reason, feel necessity of easy and efficient conversion. This paper argues efficient methodology to change Verilog to SystemC. Abstract concepts of Verilog are proposed fittingly each one by one in SystemC.

  • PDF

Performance Analysis of OFDM/QPSK-DMR System Using One-Tap Adaptive Equalizer over the Microwave Channel (Microwave 채널 환경에서 One-Tap 적응 등화기를 적용하는 OFDM/QPSK-DMR 시스템의 성능 분석)

  • Yang, Hee-Jin;Ahn, Jun-Bae;Oh, Chang-Heon;Cho, Sung-Joon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.398-402
    • /
    • 2003
  • In this paper, we have analyzed the performance enhancement of OFDM/QPSK-DMR(Orthogonal Frequency Division Multiplexing/Quadrature Phase Shift Keying Modulation-Digital Microwave Radio)system using BL-PSF(Band Limited-Pulse Shaping Filter) over the microwave channel. For performance enhancement, we apply the one-tap adaptive equalizer for OFDM/QPSK-DMR system and compare with the BER performance of single carrier DMR system. Computer simulations confirm that the OFDM/QPSK-DMR system using one-tap adaptive equalizer has the same BER performance for the single carrier DMR system.

  • PDF

Characteristics of the Ice Slurry Transportation System for District Cooling Depending on the Transportation Lines (지역냉방용 아이스슬러리 수송시스템의 배관방식에 따른 특성)

  • Lee Yoon-Pyo;Chung Jae-Dong;Yoon Seok-Mann
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.571-577
    • /
    • 2006
  • The characteristics of ice packing factor (IPF) at the ice slurry system using one line type are compared with the system using two lines type. The installation space for one transporting line is saved at the one line system. For the one line type, the ice packing factor is reduced along the downstream, but for the two lines type, the ice packing factor is fixed. For the one line system, mass flow rate in the main line is fixed along the down-stream, but for two lines system, the mass flow rate in the main line is reduced along the downstream. For one line system, along the down stream after IPF=0, the temperature at the main steam is increased, and the extracted mass flow is increased. The initial IPF, at which the IPF is not arrived at zero upto the final node, is proposed for the B area.

Development of an IoT System Based on the oneM2M Communication Protocol (oneM2M 통신 프로토콜 기반 사물인터넷 시스템 개발)

  • Park, Kee-Hyun;Lee, Jong-Hwi;Woo, Min-Woo;Park, Joon-Suu
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.3
    • /
    • pp.41-49
    • /
    • 2016
  • In this paper, an IoT system which is increasingly popular in these days is developed. Among various international standards on the area, one M2M communication protocol is used in the system. The 0neM2M-based IoT system consists of ADN-AE modules and CSE modules. The ADN-AE module provides applications of various services. It also monitors a CSE module. The CES module is a platform that provides common services which should be provided to various AEs in an IoT system. The CSE module consists of a Network Manager module, a Message Handler module, and a Resource Manager module. The Network Manager module controls oneM2M communication and data flow in the system. The Message Handler module processes transmitted messages and the Resource Manager module manages the Resource Tree. The resource tree stores information of the objects to be managed in the system. Also, internal data flow and protocol mapping in the modules are explained.

A precision temperature control system using one-board micom (One-board micom을 이용한 정밀 온도 제어 시스템)

  • 주해호;조덕현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.457-461
    • /
    • 1988
  • In this study an one-board micom controlled precision temperature control system has been developed. The digital temperature control system is consisted of an one-board micom as digital controller, a 12-bit A/D and D/A converter, a power amplifier, a NTC thermister, a preamplfier and a heat chamber. An operating control program for the control system was written in Z80 machine language. A Dual-PID predictor control algorithm was proposed. Experments were conducted with different sampling time and limitted error value. As a result, the temperature in a heat chamber can be well controlled within +- 0.2 .deg.C when the sampling time was applied to 10 sec and the limitted error value +- 0.5 .deg.C under the dual-PID predictor control algorithm. By means of one-board micom overall system has been reduced in size and volume, thus the system becomes compact and less expensive.

  • PDF