• Title/Summary/Keyword: One switch

Search Result 711, Processing Time 0.038 seconds

A study on the capacity analysis of wide area radio trunking system (광역 무선 Trunking 시스템의 통신용량 분석에 관한 연구)

  • 김낙명
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.4
    • /
    • pp.1-11
    • /
    • 1997
  • In this paper, modeling of the communication channel occupancy characteristics at the base station in the wide area radio trunking syste has been performed. Using the results, mathematical analysis for the switching capacity at the network switch has also been done. Specificatlly, we propose a G/M/m queueing model for the single service area modeling, and analyze changes in call blockingprobabilities accoridng to changes in the burstness characteristics of group paging calls. As a result, we have observe dthat the channel occupancy variations become larger as the burstness characteristics become more apparent, to make the call blocking probability higher. Next, based on the single service area analysis, we have anayzed mathematically the average switching capacity required to serve mobile subscribers for a wide area radio trunking sytem, where multiple switching port assignments are required when the people in the same group are distributed over several base stations. Accordingly, we have observed that the average and the variance of switching channel occupancy are closely related to the mobility characteristics of subscribers, and that we need a netowrk switch having bigger capacity as subscribers show wider distribution. Especially, with the call dropping probability within 0.2%, a switch having about 5 to 6 times bigger can be required, compared with the one when the mobility of subscribers is mostly restricte dto a single service area.

  • PDF

Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1015-1024
    • /
    • 2015
  • This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.

Development of a Lighting Control Switch Using Power Line Communication Technology (전력선 통신기술을 이용한 조명제어 스위치의 개발)

  • Song Jae-yong;Moon Seung-bo;kil Gyung-suk;Lee Gyung-soo;Kim Chang-yul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.792-797
    • /
    • 2005
  • Lighting control switches based on the power line communication technology are developed and extended to incorporate dimming control to provide energy saving and appropriate illumination. The developed switch uses a general purpose microprocessor and associated electronics. Both the power line communication and the dimming function are implemented in one microprocessor, and it enables the low price commercialization. The frequency of the carrier was set at 250kHz considering the transmission data length and signal attenuation in power lines. Tests on prototypes in an low-voltage power lines have shown that the switches have a robust operation characteristics with the length of power lines and the variation of load capacities.

Study on the High Voltage Pulse Profile Characteristics of a Turbulently Heated Theta Pinch (난류가열 쎄타핀치의 고전압 펄스 발생에 관한 연구)

  • 강형보;정운관;육종철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.11
    • /
    • pp.456-463
    • /
    • 1984
  • The fast-rising high-voltage pulse generation circuit system of a theta pinch is both theoretically and experimentally investigated. The idealized model of this circuit system is a hybrid circuit system composed of three parts: a lumped circuit part being consisted of a capacitor bank and a spark switch connected in series, another lumped circuit part being consisted of the Blumlein transmission line, whose end load is the pinch coil. the voltage difference between two ends of the pinch coil is formulated by analyzing this hybrid circuit system by means of the law of the signal propagation in the transmission line and Kirchhoff's laws. The expedient numerical method for computer calculation is developed to generate the pulse profile of the voltage difference across the pinch coil. The period of the experimentally measured main pulse is a fourth of the theoretical one neglecting the resistance of the pinch coil. We attribute this discrepancy to the modelling in the theoretical calculation that hte resistance and inductance of the spark switch and capacitor bank are assumed to be constant through discharge. Therefore, we can see that the rise time of the imploding magnetic-field pulse is mainly dependent on the spark switch and capacitor bank.

  • PDF

Mapping and Scheduling for Circuit-Switched Network-on-Chip Architecture

  • Wu, Chia-Ming;Chi, Hsin-Chou;Chang, Ruay-Shiung
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • Network-on-chip (NoC) architecture provides a highper-formance communication infrastructure for system-on-chip designs. Circuit-switched networks guarantee transmission latency and throughput; hence, they are suitable for NoC architecture with real-time traffic. In this paper, we propose an efficient integrated scheme which automatically maps application tasks onto NoC tiles, establishes communication circuits, and allocates a proper bandwidth for each circuit. Simulation results show that the average waiting times of packets in a switch in $6{\times}6$6, $8{\times}8$, and $10{\times}10$ mesh NoC networks are 0.59, 0.62, and 0.61, respectively. The latency of circuits is significantly decreased. Furthermore, the buffer of a switch in NoC only needs to accommodate the data of one time slot. The cost of the switch in the circuit-switched network can be reduced using our scheme. Our design provides an effective solution for a critical step in NoC design.

  • PDF

The Design, Fabrication, and Characteristic Experiment for Control Rod Position Indicator Using Reed Switch in System-Integrated Modular Advanced Reactor (리드스위치를 이용한 일체형원자로용 제어봉 위치지시기 설계 제작 및 특성해석)

  • Hur, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.452-461
    • /
    • 2003
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indicator system and its actual implementation in the existing nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indicator. The hysteresis of reed switches is one of the important factors in a repeat accuracy of control rod position indicator as well. This paper investigates efficiency of the magnetic flux concentrator and the hysteresis using FEM and verified differences in physicals characteristics by comparing the results of FEM and those of the experiment. As a result, it is shown that the characteristics of prototype control rod position indicator have a good agreement with the results of FEM.

Utility-Interactive Four-Switch Three-Phase Soft-Switching Inverter with Single Resonant DC-Link Snubber and Boost Chopper

  • Ahmed, Tarek;Nagai, Shinichiro;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.109-117
    • /
    • 2007
  • In this paper, a novel proposal for a utility-interactive three-phase soft commutation sinewave PWM power conditioner with an auxiliary active resonant DC-link snubber is developed for fuel cell and solar power generation systems. The prototype of this power conditioner consists of a PWM boost chopper cascaded three-phase power conditioner, a single two-switch auxiliary resonant DC-link snubber with two electrolytic capacitors incorporated into one leg of a three-phase V-connection inverter and a three-phase AC power source. The proposed cost-effective utility-interactive power conditioner implements a unique design and control system with a high-frequency soft switching sinewave PWM scheme for all system switches. The operating performance of the 10 kW experimental setup including waveform quality, EMI/RFI noises and actual efficiency characteristics of the proposed power conditioner are demonstrated on the basis of the measured data.

An Efficiency Improvement Method for Single-phase Boost Converter by Reducing Switching Loss (스위칭 손실 감소에 의한 단상 부스트 컨버터의 효율개선)

  • Kim Jong-Su;Oh Sae-Gin;Park Keun-Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.96-103
    • /
    • 2006
  • This paper proposes a new technique for improving the efficiency of single phase high frequency switch mode boost converter. This converter includes an additional boost converter that follows the main hish frequency switching device. The additional converter, which is controlled at lower frequencies, bypasses almost all the current in the main switch and the high frequency switching loss is greatly reduced. Both switching devices are controlled by a simple method; each controller consists of a one-shot multivibrator, a comparator and an AND gate, and the maximum switching frequency can be limited without any clock generator. The converter works cooperatively in high efficiency and acts as though it were a conventional high frequency switch mode converter with one switching device. This paper describes the proposed converter configuration, design, and discusses the steady state performance concerning the switching loss reduction and efficiency improvement. and the proposed method is verified by computer simulation.

Coronary Artery Compression after an Arterial Switch Operation for Transposition of the Great Arteries - A case report- (대혈관전위로 동맥치환술을 시행했던 환자에서 발생한 관상동맥 압박 -1예 보고-)

  • Yoo, Jae-Suk;Koak, Jae-Gun;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.360-362
    • /
    • 2008
  • An adequate location of the reimplanted coronary arteries is one of the most important prognostic factors for an arterial switch operation for treating TGA (transposition of great arteries). We report here on a case of malposition of the reimplanted coronary artery in a 14-year-old boy who had undergone an arterial switch operation. He had chest pain and dyspnea on exertion. The imaging study showed that the ostium of the left main coronary artery, which was between the neo-pulmonary artery and the neo-aorta, was compressed by the great arteries. We excised the left main coronary artery with a button incision from the aorta and reimplanted it on the left lateral side of the aorta. The patency of the left main coronary artery os after the operation was good and it was not compressed by the surrounding arteries.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.