• Title/Summary/Keyword: One for All

Search Result 21,996, Processing Time 0.06 seconds

Note on Properties of Noninformative Priors in the One-Way Random Effect Model

  • Kang, Sang Gil;Kim, Dal Ho;Cho, Jang Sik
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.3
    • /
    • pp.835-844
    • /
    • 2002
  • For the one-way random model when the ratio of the variance components is of interest, Bayesian analysis is often appropriate. In this paper, we develop the noninformative priors for the ratio of the variance components under the balanced one-way random effect model. We reveal that the second order matching prior matches alternative coverage probabilities up to the second order (Mukerjee and Reid, 1999) and is a HPD(Highest Posterior Density) matching prior. It turns out that among all of the reference priors, the only one reference prior (one-at-a-time reference prior) satisfies a second order matching criterion. Finally we show that one-at-a-time reference prior produces confidence sets with expected length shorter than the other reference priors and Cox and Reid (1987) adjustment.

3D Shape Reconstruction from 2D Cross-Sections (단면 정보를 이용한 형상의 재구성)

  • Park, H.J.;Kim, K.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.4
    • /
    • pp.81-93
    • /
    • 1993
  • The three dimensional(3D) shape reconstruction from two dimensional(2D) cross-sections can be completed through three main phases : the input compilation, the triangular grid formation, and the smooth surface construction. In the input compilation phase, the cross-sections are analyzed to exctract the input data required for the shape reconstruction. This data includes the number of polygonized contours per cross-section and the vertices defining each polygonized contour. In the triangular grid formation phase, a triangular grid, leading to a polyhedral approximations, is constructed by extracting all the information concerning contour links between two adjacent cross- sections and then performing the appropriate triangulation procedure for each contour link. In the smooth surface construction phase, a smooth composite surface interpolating all vertices on the triangular grid is constructed. Both the smooth surface and the polyhedral approximation can be used as reconstructed models of the object. This paper proposes a new method for reconstructing the geometric model of a 3D objdect from a sequence of planar contours representing 2D cross-sections of the objdect. The method includes the triangular grid formation algorithms for contour closing, one-to-one branching, and one-to-many braanching, and many-to-many branching. The shape reconstruction method has been implemented on a SUN workstation in C.

  • PDF

Association of Hospital Procedure Volume with Post-Transplant Survival for Allogeneic Bone Marrow Transplantation (동종조혈모세포이식술 시술기관의 진료량이 이식후 생존율에 미치는 영향)

  • Park, Choon-Seon;Moon, Hee-Kyung;Kang, Hye-Young;Min, Yoo-Hong;Cho, Woo-Hyun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.1
    • /
    • pp.26-36
    • /
    • 2004
  • Objective : To examine the association between hospital procedure volume and treatment outcomes following allogeneic bone marrow transplantation (allo-BMT). Methods : Out of 1,050 patients who received allo-BMTs between 1998 and 2000 in 21 Korean hospitals, 752 with first allo-BMT and complete data were included in this study. Study subjects were divided into the following three groups according to cumulative hospital experience of all-BMTs during the study period: low (<30 cases), medium (30-49) and high ($\geq$50 cases) volume. Patient outcome was defined as early survival at day 100 and one-year survival. Multiple logistic regression analyses were performed to examine the association between hospital experience and survival at day 100 and one year. Results : When the low volume group was defined as the reference group, the adjusted relative risks (RR) of survival at day 100 for the high volume group were 2.46(95% CI, 1.13-5.36) for all patients, 2.61(1.04-6.57) for those with leukemia, and 2.20(0.47-10.32) for those with aplastic anemia. For one-year survival, adjusted RR for the high volume group were 2.52(1.40-4.51) for all patients, 1.99 (1.01-3.93) for leukemia, and 6.50(1.57-26.80) for aplastic anemia. None of the RR for the medium volume group was statistically significant. Patient factors showing significant relationship with survival were donor-recipient relation, human leukocyte antigen matching status, time from diagnosis to transplant, and disease stage. Conclusions : The study results suggest that the cumulative experience of hospitals in providing allo-BMT is positively associated with patient survival.

HOMOGENEOUS SOLUTION FOR SW LACERTAE

  • Kim, Kyung-Joo;Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.19-31
    • /
    • 1996
  • We have analyzed collected photoelectric light curves for light variations of SW Lac. The method of Fourier analysis was adopted to quantify the light variation from season to season. We found the linear relation between the Fourier coefficient, B1 and the magnitude difference between two maxima. The total light of the system has been decreased as much as 0m.04 during approxiamately 20 years time interval. Photoelectric parameters including spot parameters for all light curves were obtained by the method of the Wilson and Devinney differential correction in order to secure the variations of parameters from season to season. SW Lac, not like RS CVn type stars, required to adjust all parameters as well as spot parameters for a reasonable fit to the observations of each epoch. A surface temperature of cooler star is one of the most sensitive parameters to affect a shape of light curve of SW Lac. We conclude that the shape of light curve of SW Lac varies even during one season as well as season to season. The light curve is mainly caused by inhomogeneous surface temperature due to strong chromospheric activity of the system.

  • PDF

Multiple Output Charger based on the Novel Time Division Multiple Control Technique (새로운 시분할 다중 제어 기법에 기반한 다중 출력 충전기)

  • Tran, Van-Long;Choi, Woo-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.13-14
    • /
    • 2013
  • Multiple output converters (MOCs) are widely used for applications which require various kinds of the output voltages due to its advantages in cost, volume, and efficiency. However, most of the MOCs developed so far can regulate only one output tightly and require as many secondary windings in the transformer as the number of the outputs. In this paper, a novel Time Division Multiple Control (TDMC) method to regulate all the outputs in high precision is proposed and applied to the double ended forward converter for the multiple battery charger. Additional benefit of the proposed topology is to require only one secondary winding in the transformer for all the outputs. The proposed converter can charge two different kinds of batteries or same kind of batteries in different state of charges (SOCs) by CC/CV mode independently with the even degree of tight regulation, thereby satisfying the ripple requirements for each battery.

  • PDF

Surgical Thrombectomy in Deep Vein Thrombosis (심부 혈전 증의 외과적 혈전제거술)

  • Kim, Seong-Ho;Lee, Sang-Ho
    • Journal of Chest Surgery
    • /
    • v.24 no.12
    • /
    • pp.1214-1219
    • /
    • 1991
  • From July 1988 to January 1991 six patients, aged 29 to 70 years underwent transfemoral thrombectomy for the treatment of deep vein thrombosis. Preoperative venograms showed thrombi in the following locations: calf veins[five], superficial femoral or popliteal veins [four], common femoral veins[three], and iliac veins[three], Durations of symptoms before admission were from 1 day to 20days. Operations were performed under local anesthesia and all the patients were requested for doing Valsalva maneuver during thrombectomies. All patients were received heparin pre-and postoperatively, which was switched to Coumadin for preventing of rethrombosis. One patient was transferred to other hospital 4 months after operation due to regional reason, and the remained five patients were evaluated with a mean follow-up time of 20 months. There was no evidence of postoperative pulmonary embolism. Three of five patients were clinically asymptomatic. One complained of the heaviness of involved leg in the evening, and the other had discomfort on walking Even though our cases were a few in number, we concluded that thrombectomy is a valuable treatment modality of deep vein thrombosis.

  • PDF

Early Valve Replacement in Patient with Native Valve Endocarditis - Report of Seven Cases - (활동기 자가판 심내막염의 판막치환술: 7례 경험)

  • 허동명
    • Journal of Chest Surgery
    • /
    • v.24 no.10
    • /
    • pp.979-986
    • /
    • 1991
  • From October 1988 to November 1989, seven patients underwent valve replacement during the active phase of native valve endocarditis. There were 4 males and 3 females whose mean age was 41 years[range, 16 to 68 years]. Preoperative two-dimensional and Doppler echocardiography showed vegetations and severe valvular regurgitation in all patients. Blood cultures were positive in 4, and negative in 3 patients Organisms were alpha-hemolytic Streptococcus in 2, Staphylococcus epidermidis in 1, Erysipelothrix rhusiopathiae in 1 patient Valve tissue cultures were negative in all patients. Intravenous antibiotic therapy had been done for 3 to 18 days in 5 patients pre-operatively and was not done in 2 patients, Indications for operation were heart failure in h, and systemic emboli in 1 patient. The aortic valve was involved in 3, mitral in 1, and both aortic and mitral in 3 patients, One operative death[14.4%] occurred in patient with cardiogenic shock before operation. Late death occurred in one on 14 months after operation. The remaining 5 patients were followed up over a two year period in good condition. In conclusion, native valve endocarditis with severe heart failure must be considered for early operation.

  • PDF

Development of One-to-One Shortest Path Algorithm Based on Link Flow Speeds on Urban Networks (도시부 가로망에서의 링크 통행속도 기반 One-to-One 최단시간 경로탐색 알고리즘 개발)

  • Kim, Taehyeong;Kim, Taehyung;Park, Bum-Jin;Kim, Hyoungsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.38-45
    • /
    • 2012
  • Finding shortest paths on time dependent networks is an important task for scheduling and routing plan and real-time navigation system in ITS. In this research, one-to-one time dependent shortest path algorithms based on link flow speeds on urban networks are proposed. For this work, first we select three general shortest path algorithms such as Graph growth algorithm with two queues, Dijkstra's algorithm with approximate buckets and Dijkstra's algorithm with double buckets. These algorithms were developed to compute shortest distance paths from one node to all nodes in a network and have proven to be fast and efficient algorithms in real networks. These algorithms are extended to compute a time dependent shortest path from an origin node to a destination node in real urban networks. Three extended algorithms are implemented on a data set from real urban networks to test and evaluate three algorithms. A data set consists of 4 urban street networks for Anaheim, CA, Baltimore, MD, Chicago, IL, and Philadelphia, PA. Based on the computational results, among the three algorithms for TDSP, the extended Dijkstra's algorithm with double buckets is recommended to solve one-to-one time dependent shortest path for urban street networks.

A COMPARATIVE STUDY ON THE FLEXURE STRENGTH OF THE CERAMICS FOR ALL-CERAMIC CROWNS (All-ceramic Crown 용 도재의 굽힘강도에 관한 비교연구)

  • Yu Hyoung-Woo;Song Chang-Yong;Bae Tae-Seong;Song Kwang-Yeob;Park Chan-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.195-211
    • /
    • 1994
  • The purpose of this study was to evaluate the fracture resistance of the four kinds of dental porcelains for the all-ceramic crown(Vita In-Ceram, Vita Hi-Ceram, IPS-Empress, Vitadur-N) and one kind for the metal-ceramic non(Vita VMK 68) was used as the control group. In order to determine the fracture resistance, the hi-axial flexure strength was measured at a crosshead speed of 0.5mm/min, and the Vickers hadrness was measured at an indentation load of 1kg for 20 seconds. The results obtained were summarized as follows ; 1. The maximum Weibull modulus of 24.61 for Vitadur-N and the minimum one of 852 for IPS-Empress were observed ; the maximum characteristic strength of 353.26MPa for Vita In-Ceram and the minimum that of 63.20MPa for Vitadur-N were also observed. 2. The maximum mean bi-axial flexure strength of 339.12MPa for Vita In-Ceram and thd minimum one of 61.99MPa for Vitadur-N were calculated. Results of the Scheffe test indicated that the statistically significant difference(P<0.05) existed between Vita In-Ceram or Vita Hi-Ceram and the others ; also between IPS-Empress and Vitadur-N. 3. The maximum mean hardness of $980.55kg/mm^2$ for Vita VMK 68 appeared. Results of the Scheffe test indicated that statistically significant difference(P<0.05) existed between Vita In-Ceram or Vita Hi-Ceram and the others ; also between IPS-Empress and Vita VMK 68.

  • PDF

Deconvolution Filtering Method for All-pass Systems (전역통과 시스템에 대한 Deconvolution 필터링 기법)

  • Kim Sung-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1025-1031
    • /
    • 2006
  • In this paper, a deconvolution filtering method for all-pass systems based on FIR approximation is proposed. The proposed method enables us to obtain a causal stable deconvolution filter by FIR approximating a non-causal stable deconvolution filter to a causal stable one. As we can see in this paper, the impulse response of the deconvolution filter for all-pass system is simply the mirror image of the impulse response for all-pass system itself. Due to this symmetric property between all-pass system itself and its deconvolution Inter, this method can be applied to all-pass systems without special limitation of the system's order. In order to verify the performance of the proposed method. computer simulation results for 1st-, 2nd- and 400th-order all-pass systems are included.