• Title/Summary/Keyword: One Segment

Search Result 878, Processing Time 0.025 seconds

P Wave Detection based on QRST Cancellation Zero-One Substitution

  • Cho, Ik-Sung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2021
  • Cardiac arrhythmias are common heart diseases and generally cause sudden cardiac death. Electrocardiogram (ECG) is an effective tool that can reveal the electrical activity of the heart and diagnose cardiac arrhythmias. We propose detection of P waves based on QRST cancellation zero-one substitution. After preprocessing, the QRST segment is determined by detecting the Q wave start point and T wave end point separately. The Q wave start point is detected by digital analyses of the QRS complex width, and the T wave end point is detected by computation of an indicator related to the area covered by the T wave curve. Then, we determine whether the sampled value of the signal is in the interval of the QRST segment and substitute zero or one for the value to cancel the QRST segment. Finally, the maximum amplitude is selected as the peak of the P wave in each RR interval of the residual signal. The average detection rate for the QT database was 97.67%.

Simplified Representation of Image Contour

  • Yoo, Suk Won
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.317-322
    • /
    • 2018
  • We use edge detection technique for the input image to extract the entire edges of the object in the image and then select only the edges that construct the outline of the object. By examining the positional relation between these pixels composing the outline, a simplified version of the outline of the object in the input image is generated by removing unnecessary pixels while maintaining the condition of connection of the outline. For each pixel constituting the outline, its direction is calculated by examining the positional relation with the next pixel. Then, we group the consecutive pixels with same direction into one and then change them to a line segment instead of a point. Among those line segments composing the outline of the object, a line segment whose length is smaller than a predefined minimum length of acceptable line segment is removed by merging it into one of the adjacent line segments. As a result, an outline composed of line segments of over a certain length is obtained through this process.

Korean Sibilant /s/ before a High Front and a Round Segment

  • Kang, Hyun-Sook
    • Phonetics and Speech Sciences
    • /
    • v.2 no.4
    • /
    • pp.59-65
    • /
    • 2010
  • In this paper, we investigate acoustic characteristics of Korean /s/ when it is followed by both a high front and a round segment regardless of their order to one another. We show that Korean /s/ in this environment has characteristics of a labio-palatalized segment, being affected by both a high front and a round segment if they occur within the domain of a syllable. In the experiment, we show that Korean /s/ before a high front and a round segment shows a spectral shape different from that in other environments. Specifically, it is different from /s/ before a high front segment only, showing peaks around 2.5 kHz. Furthermore, it shows a rapid decrease of amplitude in 4-5 kHz, and sometimes another plateau of high peaks in 5-6 kHz. We also examined center of gravity frequency and band energy difference. Based on the results of this experiment, we argue that Korean /s/ is affected by the following segments within the domain of coarticulation, a syllable and that the degree of coarticulation is different from language to language.

  • PDF

Another representation of hand written English alphabets by a sequence of fuzzy sets

  • Moon, Byung-Soo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.157-160
    • /
    • 2003
  • In this paper, we describe how to represent lower case hand-written English alphabets by a sequence of two to seven fuzzy sets. Each fuzzy set represents an arc segment of the character and each arc segment is assumed to be a part of an ellipse. The part of an ellipse is defined by five quantities; its short and long radii, its orientation angle, whether it is a part of the lower half or the upper half, and whether it is the full half or a part of a half. Hence, we use the Cartesian product of five fuzzy sets to represent each arc segment. We show that this representation is a translation, rotation, and scaling invariant and that it can be used to generate the hand-written English alphabets. The representation we describe is different from the one proposed earlier by the author and when compared with the previous representation, the one described in this paper simulates more closely the behavior of how one writes English characters.

Bone Cement-Augmented Percutaneous Short Segment Fixation : An Effective Treatment for Kummell's Disease?

  • Park, Seon Joo;Kim, Hyeun Sung;Lee, Seok Ki;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.54-59
    • /
    • 2015
  • Objective : The aim of this prospective study was to evaluate the efficacy of bone cement-augmented percutaneous short segment fixation for treating Kummell's disease accompanied by severe osteoporosis. Methods : From 2009 to 2013, ten patients with single-level Kummell's disease accompanied by severe osteoporosis were enrolled in this study. After postural reduction for 1-2 days, bone cement-augmented percutaneous short segment fixation was performed at one level above, one level below, and at the collapsed vertebra. Clinical results, radiological parameters, and related complications were assessed preoperatively and at 1 month and 12 months after surgery. Results : Prior to surgery, the mean pain score on the visual analogue scale was $8.5{\pm}1.5$. One month after the procedure, this score improved to $2.2{\pm}2.0$ and the improvement was maintained at 12 months after surgery. The mean preoperative vertebral height loss was $48.2{\pm}10.5%$, and the surgical procedure reduced this loss to $22.5{\pm}12.4%$. In spite of some recurrent height loss, significant improvement was achieved at 12 months after surgery compared to preoperative values. The kyphotic angle improved significantly from $22.4{\pm}4.9^{\circ}$ before the procedure to $10.1{\pm}3.8^{\circ}$ after surgery and the improved angle was maintained at 12 months after surgery despite a slight correction loss. No patient sustained adjacent fractures after bone cement-augmented percutaneous short segment fixation during the follow-up period. Asymptomatic cement leakage into the paravertebral area was observed in one patient, but no major complications were seen. Conclusion : Bone cement-augmented percutaneous short segment fixation can be an effective and safe procedure for Kummell's disease.

A Comparison Study between Composite and Multiple Single-Segment Profile Control (Profile의 Composite와 Multiple Single-Segment Control의 비교 연구)

  • Kim, Jun-Ho;Chang, Sung-Ho;Ra, Doo-Wan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.1-6
    • /
    • 2016
  • As manufacturing industries become globalized, product design affects every area of organization. The design sets the goals for a number of different departments, so if it fails to effectively communicate these goals, the entire organization is less efficient. In addition, To communicate clearly, the design must represent a product that meets its technical specification. GD&T (Geometric Dimensioning and Tolerancing) is one of the most important factors, which has an effect on efficiency of manufacture system, in designing products. However, most of designers in different industries are prone to ignore the importance of GD&T. To analyse the importance of GD&T compliance with international standards for design drawing, a comparison analysis of the difference between two methods, composite profile control and multiple single segment profile control, is performed on three different cases and suggests how it used to be more suitable. Composite profile tolerance is specified by a dual feature control frame that has one profile symbol specified with two lines of tolerance information. Whereas a multiple single segment profile control is when two or more single segment profile callouts are used to define the location and/or orientation and/or size and/or form of a part feature. In this study, the following results will be provided : a clear definition and an obvious difference of the tolerance zone, datums and datums sequence and minimization of tolerances. On this study, composite profile tolerance and multiple single segment profile tolerance were discussed. Next steps of research will consist on reaching more accurate results for profile control. Further research will be focused on dealing with the remaining 14 symbols of GD&T.

Symptomatic Adjacent Segment Degeneration Following Posterior Lumbar Arthrodesis : Retrospective Analysis of 26 Patients Experienced in. 10-year of Periods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Kim, Il-Sup;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.184-190
    • /
    • 2007
  • Objective : The authors retrospectively analyzed clinical and radiographic features of patients who developed symptomatic adjacent segment degeneration (ASD) that required re-operation. Methods : From 1995 to 2004, among 412 patients who underwent posterior lumbar fusion surgery, the authors experienced twenty-six patients who presented symptomatic ASD. Records of these patients were reviewed to collect clinical data at the first and second operations. Results : The patients were 9 males and 17 females whose mean age was $63.5{\pm}8.7$ years. Among 319 one segment and 102 multi-segment fusions, 16 and 10 patients presented ASD, respectively. Seventeen ASDs were noticed at the cephalad to fusion (65%), eight at the caudad (31%), and one at the cephalad and caudad, simultaneously (4%). All patients underwent decompression surgery. Nine patients underwent additional fusion surgeries to adjacent degenerated segments. In 17 patients who underwent only decompression surgery without fusion, the success rate was 82.4%. In fusion cases. the success rate was observed as 55.5%. There were no statistically significant factors to be related to development of ASD. However, in cases of multi-level fusion surgery, there was a tendency toward increasing ASD. Conclusion : Multi-segment fusion surgery could be associated with a development of ASD. In surgical treatment of symptomatic ASD, selective decompression without fusion may need to be considered as a primary procedure, which could reduce the potential risk of later occurrence of the other adjacent segment disease.

Applicability estimation for cable assembling method of shield tunnel using field test construction (현장 조립 시험시공을 통한 쉴드터널 강연선 체결 기술의 적용성 평가)

  • Kim, Dong-Min;Ma, Sang-Joon;Lee, Young-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.11-23
    • /
    • 2015
  • In this study, the new segment assembling method using cable tensible force was developed to improve the problem of bolt assembling method of shield tunnel. In the field test construction, cable assembling method reduced the assembling time of segment in comparison with bolt assembling method because of guide role of segment shear-key. In the result of measuring the necessary time for segment assembling process, it took 420sec to assemble one segment in bolt method and 400sec to assemble one segment in cable method, but in case of using the cable automatic feeder, it could reduce the necessary time as 60sec in comparison with bolt assembling method. The cable automatic system modeling using BIM, that connected shield TBM also will be utilized in the area of design TBM, excavation plan, method process understanding, construction management and so on.

Analysis of Phase Change Materials for Production of Changable Mold for Free-form Concrete Segment (FCS 가변형 몰드 생산을 위한 PCM 분석)

  • Lee, Donghoon;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.150-151
    • /
    • 2014
  • A mold of free-form concrete segment can be used only one time. Thus, the construction duration and cost are increased. The materials of the mold such as wood and metal have limitations due to the implementation and reuse. The review of the material of the mold for free-form concrete segment is needed to reduce duration and production cost. Phase change material can be used both to implement free-shape by heating and to produce mold after cooling. After using Phase change material can be re-used to mold by heating. The scope of this study is many kind of phase change materials for molding. The aim of this study is to analyze the phase change materials for production of changable mold for free-form concrete segment. In this study, the paraffin wax that is melted at 64℃ was selected by considering both the energy efficiency and the weather of Korea.

  • PDF

Radiologic Findings and Risk Factors of Adjacent Segment Degeneration after Anterior Cervical Discectomy and Fusion : A Retrospective Matched Cohort Study with 3-Year Follow-Up Using MRI

  • Ahn, Sang-Soak;So, Wan-Soo;Ku, Min-Geun;Kim, Sang-Hyeon;Kim, Dong-Won;Lee, Byung-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • Objective : The purpose of this study was to figure out the radiologic findings and risk factors related to adjacent segment degeneration (ASD) after anterior cervical discectomy and fusion (ACDF) using 3-year follow-up radiography, computed tomography (CT), and magnetic resonance image (MRI). Methods : A retrospective matched comparative study was performed for 64 patients who underwent single-level ACDF with a cage and plate. Radiologic parameters, including upper segment range of motion (USROM), lower segment range of motion (LSROM), upper segment disc height (UDH), and lower segment disc height (LDH), clinical outcomes assessed with neck and arm visual analogue scale (VAS), and risk factors were analyzed. Results : Patients were categorized into the ASD (32 patients) and non-ASD (32 patients) group. The decrease of UDH was significantly greater in the ASD group at each follow-up visit. At 36 months postoperatively, the difference for USROM value from the preoperative one significantly increased in the ASD group than non-ASD group. Preoperative other segment degeneration was significantly associated with the increased incidence of ASD at 36 months. However, pain intensity for the neck and arm was not significantly different between groups at any post-operative follow-up visit. Conclusion : The main factor affecting ASD is preoperative other segment degeneration out of the adjacent segment. In addition, patients over the age of 50 are at higher risk of developing ASD. Although there was definite radiologic degeneration in the ASD group, no significant difference was observed between the ASD and non-ASD groups in terms of the incidence of symptomatic disease.