• Title/Summary/Keyword: One Scan Method

Search Result 297, Processing Time 0.028 seconds

Clinical Implication of Cyclooxygenase-2 Expression for Rectal Cancer Patients with Lymph Node Involvement (림프절 전이를 동반한 직장암 환자들에서 Cyclooxygenase-2 발현의 임상적 의미)

  • Lee, Hyung-Sik;Choi, Young-Min;Hur, Won-Joo;Kim, Su-Jin;Kim, Dae-Cheol;Roh, Mee-Sook;Hong, Young-Seoub;Park, Ki-Jae
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.210-217
    • /
    • 2009
  • Purpose: To assess the influence of cyclooxygenase-2 (COX-2) expression on the survival of patients with a combination of rectal cancer and lymph node metastasis. Materials and Methods: The study included rectal cancer patients treated by radical surgery and postoperative radiotherapy at the Dong-A university hospital from 1998 to 2004. A retrospective analysis was performed on a subset of patients that also had lymph node metastasis. After excluding eight of 86 patients, due to missing tissue samples in three, malignant melanoma in one, treatment of gastric cancer around one year before diagnosis in one, detection of lung cancer after one year of diagnosis in one, liver metastasis in one, and refusal of radiotherapy after 720 cGy in one, 78 patients were analyzed. The immunohistochemistry for COX-2 was conducted with an autostainer (BenchMark; Ventana, Tucson, AZ, USA). An image analyzer (TissueMine; Bioimagene, Cupertino, CA, USA) was used for analysis after scanning (ScanScope; Aperio, Vista, CA, USA). A survival analysis was performed using the Kaplan Meier method and significance was evaluated using the log rank test. Results: COX-2 was stained positively in 62 patients (79.5%) and negatively in 16 (20.5%). A total of 6 (7.7%), 15 (19.2%), and 41 (52.6%) patients were of grades 1, 2, and 3, respectively for COX-2 expression. No correlation was found between being positive of COX-2 patient characteristics, which include age (<60-year old vs. $\geq$60), sex, operation methods (abdominoperineal resection vs. lower anterior resection), degrees of differentiation, tumor size (<5 cm vs. $\geq$5 cm), T stages, N stages, and stages (IIIa, IIIb, IIIc). The 5-year overall and 5-year disease free survival rates for the entire patient population were 57.0% and 51.6%, respectively. The 5-year overall survival rates for the COX-2 positive and negative patients were 53.0% and 72.9%, respectively (p=0.146). Further, the 5-year disease free survival rates for the COX-2 positive and negative patients were 46.3% and 72.7%, respectively (p=0.118). The 5-year overall survival rates were significantly different (p<0.05) for the degree of differentiation, N stage, and stage, whereas the 5-year disease free survival rates were significant for N stage and stage. Conclusion: Being positive for and the degree of COX-2 expression did not have a significant influence on the survival of rectal cancer patients with lymph node metastasis. However, N stage and stage did significantly influence the rateof survival. Further analysis of a greater sample size is necessary for the verification of the effect of COX-2 expression on the survival of rectal cancer patients with lymph node involvement.

Pulmonary Thromboendarterectomy for Pulmonary Hypertension Caused by Chronic Pulmonary Thromboembolism (만성폐색전중으로 인한 폐동맥고혈압 환자에서 시행한 폐동맥내막절제술)

  • Song Seung-Hwan;Jun Tae-Gook;Lee Young-Tak;Sung Ki-Ick;Yang Ji-Hyuk;Choi Jin-Ho;Kim Jin-Sun;Kim Ho-Joong;Park Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.626-632
    • /
    • 2006
  • Background: Pulmonary hypertension caused by chronic pulmonary embolism is underrecognized and carries a poor prognosis. Medical therapy is generally unsatisfactory and palliative. With the improvement of operative technique and postoperative management, pulmonary endarterectomy has been the treatment of choice for this condition. Material and Method: Between January 2001 and December 2005, eleven patients were received pulmonary endarterectomy. All patients had chronic dyspnea and exercise intolerance. Diagnosis was made with cardiac echocardiography, lung perfusion scan and computed tomography. Before the operation, Greenfield vena cava filter were placed in all patient except one. Deep hypothermic circulatory arrest was used for the distal-most portion of the endarterectomy procedure. More than moderate degree of tricuspid reguirgitation was repaired during operation. Result: There was no early and late death. Right ventricular systolic pressure was reduced significantly after operation from $91{\pm}21$ mmHg to $40{\pm}17$ mmHg on echocardiography (p=0.001). NYHA class and tricuspid reguirgitaion were improved postoperatively. Although mild reperfusion injury in three case and postoperative delirium in one case were observed, all of them recovered without complication. Conclusion: Pulmonary thromboendarterctomy offers to patient an acceptable morbidity rate and anticipation of clinical improvement. This method is safe and effective operation for pulmonary hypertension caused by chronic pulmonary thromboembolism.

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Clinical Analysis of Video Assisted Thoracic Surgery for the Treatment of Thoracic Empyema (비디오 흉강경을 이용한 농흉수술의 임상분석)

  • Oh, Sang-Gi;Song, Sang-Yun;Yun, Chi-Hyeong;Na, Kook-Ju;Kong, Kang-Eun;Park, Song-Ran;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Background: Thoracic empyema remains a serious problem despite the availability of modern diagnostic methods and appropriate antibiotics. The condition presents in many different forms and stages that require different therapeutic options. Video-assisted thoracic surgery (VATS) has become increasingly popular for use in the treatment of empyema. Material and Method: From January 2005 to May 2009, VATS was performed in 36 patients with pleural empyema and for whom chest-tube drainage and antibiotic therapy had failed or the CT scan showed multiseptate disease. The perioperative clinical factors were analyzed for all the study patients. Result: All the patients underwent VATS, but it was necessary to convert to thoracotomy in one patient. The mean operation time was $90{\pm}38.5\;min$. For the operative evaluation, 11 patients were compatible with ATS stage III. The duration of chesttube insertion was $11.9{\pm}5.8$ (3~24) days. One patient did not improve and therefore this patient underwent additional open drainage. At discharge, costophrenic angle blunting was observed in 22 patients, pleural thickening was noted in 20 patients, both were noted in 17 patients and neither was noted in 11 patients. However, at follow-up, each of these changes was observed in 9, 7, 4 and 24 patients, respectively. All except one patient showed radiographic improvement. Conclusion: VATS is suitable for the treatment of early and fibrinopurulent thoracic empyema, and even in selected patients with stage III disease.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

Comparative Volume Measuring Methods According to the Tumor Characters in PET/CT (PET/CT 검사에서 종양의 특성에 따른 체적 측정 방법 비교)

  • Choi, Yong Hoon;Ban, Yung Gak;Oh, Shin Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose Recent retrospective studies are being actively conducted to analyze the survival of patients with SUVmax, MTV, TLG, such as information from a variety of PET originating. However, there is no clear way is difficult to accurately measure the volume of the tumor may be the difference between the caster is raised. In this study, to evaluate compare the volume measuring methods according to the characteristics of the tumor. Materials and Methods 18F-saline to fill the NEMA IEC Body Phantom insert the volume of balance and imbalance in phantom were acquired to the Biograph truepoint 40 (Siemens medical system, Germany) PET/CT scanner. The ratio of the volume and Background was acquired as 3.0, 5.0, 8.0, 18, 40. Clinical patients were randomly selected 120 people in staging patients with cancer of the digestive system from the year 2010 until the year 2014. Measurement methods were used a 40% threshold, 50% threshold and gradient segmentation technique, i.e. PET EDGE. Five years of experience of the two radio-technologist and one doctor was measured by repeated three times. Analysis methods were Intraclass correlation coefficient and Pearson correlation. Results In Phantoms, the 40% threshold method gave the best concordance between measured and actual volumes (r = 0.992, 0.997). In clinical patient outcome agreement between observers EDGE it is as high as 0.999 (CI: 0.998-0.999). And there were no statistical significance of the difference between the measurements (P = 0.620). 40% threshold method showed the best correlation between the measurements (r = 0.953). Increasing the ratio of tumor to background decreased the influence of a measuring method. Conclusion How to measure volume of the tumor in the patient was clinically most useful is 50% and the lowest impact on the characteristics of the tumor. Therefore, to reduce the background of the patients in PET/CT scan, it should be required research and effort.

  • PDF

A Clinical Review of Primary Tracheal Carcinoma (원발성 악성기관종양의 임상적 고찰)

  • Ryu, Jeong-Seon;Cho, Hyun-Myung;Yang, Dong-Gyoo;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.766-775
    • /
    • 1997
  • Background : Primary malignant tumors of the trachea are extremely rare entities and account for a mere 0.1 per cent of all malignancies of the respiratory tract. Because of vague localizing signs, symptoms and a usually negative routine chest film, the patients with tracheal tumors are often treated for asthma or chronic obstructive pulmonary disease for considerable period of time before correct diagnosis. Method : We have made a review of the 17 cases of primary tracheal tumors in recent 15 years. We reviewed the clinical features including history of smoking and respiratory symptoms, the official readings of initial routine chest film, the cytologic examination of sputum, the time of delay in diagnosis, and the response according to the therapeutic modalities. Results : Eight out of 9 patients with squamous cell carcinoma(SCC) were above 50 years old, five out of 6 patients with adenoid cystic carcinoma(ACC) were below 50 years old. The most common location of primary tracheal tumors was the upper one-third of trachea in 8 cases(47%). The most frequent symptoms were dyspnea in 13/17 cases(76%) and then stridor or wheezing, cough. and sputum in order. The routine chest roentgenographic examinations were not helpful to diagnose tracheal carcinoma and the cytologic examinations of sputums were helpful to diagnose tracheal carcinoma in only one case with adenocarcinoma. The mean times of delay in diagnosis of patients with sec and ACC were 5 months and 24.9 months respectively. We had bronchial asthma in 8 cases(47%) and tracheal tumors in 4 cases(23%) as initial clinical impression. Conclusion : We would like to perform more comprehensive diagnostic tools(high KVP technique, the fibroptic bronchoscopic examination, chest CT scan etc.) in patients who had the suggestive points for the tracheal tumorse(1. unexplained hemoptysis or hoarsness, 2. inspiratory wheezing or stridor, 3. wax and waning of dyspnea according to changes of position, 4. progressive asthmatics unresponsive to antiasthmatic therapy) and radical resection of tumor or external radiation therapy with curative aim as possible.

  • PDF

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Significance of Random Urine ${\beta}_2$-Microglobulin as a Marker for Vesico-ureteral Reflux in Children with Urinary Tract Infection (요로감염 환자에서 방광요관역류의 지표로서 무작위 추출뇨중 ${\beta}_2$-microglobulin의 의의)

  • Kim Ji-Hong;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.1
    • /
    • pp.72-79
    • /
    • 1999
  • Renal scarring associated with vesico-ureteral reflux(VUR) is one of the major causes of end stage renal failure and renal hypertension in children. Urinary ${\beta}_2$-microglobulin(MG) has been suggested as a potential marker for presence of renal tubular damage. This study was designed to evaluate the significance of random urine ${\beta}_2$-MG as a predictor of presence of vesico-ureteral reflux in children with urinary tract infection(UTI). 57 children with urinary tract infection were studied. Patients were devided into two groups; 35($78.9\%$) children have UTI without VUR and 12($21.1\%$) children have UTI and VUR. Beta2-MG and creatinine in random urine sample was measured to decide the excretion ratio(${\beta}_2$-MG/creatinine). Among the 57 children with UTI, 44 children were confirmed by urine culture study and 13 children suspected by compatible clinical feature. Random urine ${\beta}_2$-MG of VUR group ($2.2{\pm}5.91$ mg/L) were significantly higher than that of simple UTI group($0.19{\pm}0.16mg/L$)(P=0.03). The ${\beta}_2$-MG/creatinine ratio of VUR group($32.41{\pm}25.7$) were significantly higher than that of simple UTI group($3.93{\pm}3.44$)(P=0.007). In conclusion, random urine ${\beta}_2$-MG and excretion ratio deserved early predictor of presence of VUR in children with UTI. And this method was more simple and inexpensive than the method of measuring ${\beta}_2$-MG with 24 hour urine collection, so might be a useful screening test for VUR in children with UTI.

  • PDF