• 제목/요약/키워드: Ondol Floor

검색결과 143건 처리시간 0.028초

전통온돌방의 실내온열환경 및 온열감에 관한 연구 (Evaluation of Indoor Thermal Environment and Thermal Sensation in Traditional Ondol Room)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 2004
  • The aim of the research was to evaluate the characteristics of indoor thermal environment and thermal sensation in the traditional Ondol room. Indoor thermal factors including air temperature, operative temperature, floor surface temperature, relative humidity, PMV, OT were measured, and survey was carried out to understand subjective responses of resident's related to indoor thermal environment in Ondol room. The analysed houses are: the Chung hyo dang(the head house of Ryu family in Andong) and the Pyeung won jung(the traditional house in Yesan). The purpose of the survey was to know the relationship between resident's sensation and thermal environmental indicators such as air temperature, relative humidity, floor surface temperature, OT. The experimental results have pointed out how Ondol room may lead to comfortable and uniform indoor thermal environments.

습식온돌시스템과 전기온돌시스템의 열성능 평가 (Thermal Performance Assessment of Wet Ondol and Electric Ondol System)

  • 한병조;구경완
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색 (A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society)

  • 정정남
    • 건축역사연구
    • /
    • 제27권3호
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

주택에 설치한 온돌 마루 및 붙박이 가구에서 발생하는 휘발성유기화합물의 농도 감소 예측 (Prediction of Concentration Decay of Volatile Organic Compounds from Ondol Floor and Furniture)

  • 조현;방승기;백용규;손장열
    • KIEAE Journal
    • /
    • 제5권1호
    • /
    • pp.51-57
    • /
    • 2005
  • In this study, time-dependent concentration variations of VOCs from fixed furniture and Ondol floor widely used as finishing material of the floor were measured, and prediction equations were developed based on the measured results. VOCs were measured and analyzed based on EPA TO-17 and NIOSH 1500, 1501 method respectively, and GC/FID were used for the analysis of VOCs concentration. Measurements were carried out for 10 days after the installation of furniture and for 40 days after the installation of the floor in the residence constructed more than 10 years ago. In both case of floor and furniture installation, time-dependent concentration decay of VOCs can be properly converted into logarithmic scale. Especially in case of furniture, toluene showed the highest concentration and took longest time to decay. As a result of the prediction of VOCs concentration decay under different air change rate using estimated equations, concentration decay rate of indoor VOCs increased rapidly as the air change rate also increased.

온돌난방주택의 난방방식별 열 특성에 관한 실험연구 (Experimental Study on the Thermal Characteristics in Ondol Heating Systems)

  • 윤정숙
    • 한국주거학회논문집
    • /
    • 제1권1호
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

창덕궁 성정각의 건축 시기와 건축 구조 (The Construction Period and the Structure of Seongjeonggak Hall, in Changdeokgung Palace)

  • 이종서
    • 건축역사연구
    • /
    • 제28권2호
    • /
    • pp.41-52
    • /
    • 2019
  • Seongjeonggak Hall in Changdeokgung Palace, although built after the Japanese Invasion in 1592, displays the architectural style and structure of Early Joseon period. It did not include ondol (Korean floor heating system) and contained Early Joseon style window frames. Later, King Jeongjo installed ondol as he repaired the building into a more convenient office. The initial construction of Seongjeonggak Hall was based on the architectural ideology of the Early Joseon Period, which divided up the space according to the season. Thus, the initial structure of the building consisted of a joint of a one-story building and a two-story building with the top floor of the latter specialized for hot and humid season. The two-story building was called 'chimnu(寢樓)', and its top floor was called 'nu-chimsil(樓寢室)'.

제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구 (An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification)

  • 이상엽;황석호;김가현;이승복
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析) (Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System)

  • 김영득;민만기;이상혁;김원갑
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

온돌난방에서의 자세에 따른 온열생리적 반응의 성차 (Effectsd of posture on physiological thermal responses with Ondol heating system)

  • 신정화;최정화
    • 한국의류학회지
    • /
    • 제22권8호
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

공동주택 층간단열 완충재의 열에너지 특성의 관한 연구 (A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House)

  • 최동혁;최경석;강재식;이승언;조우진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF