• 제목/요약/키워드: On-line system analysis

검색결과 2,442건 처리시간 0.03초

유압 브레이커의 리턴 라인의 압력 맥동 감소에 관한 연구 (A Study on the Reducing the Return Line Pressure Fluctuation of the Hydraulic Breaker System)

  • 성원준;노태봉;송창섭
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.70-76
    • /
    • 2003
  • In this study, the hydraulic breaker system was analyzed and simulated using. The simulation result was certified comparing with the experimental result. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the method to reduce the return line pressure fluctuation was presented.

전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석 (Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

Analysis of Induced Voltage on Telecommunication Line in Parallel Distribution System

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Lee, Soon-Jeong;Kim, Chul-Hwan;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.726-732
    • /
    • 2014
  • A current flowing through a distribution conductor produces induced voltage, which is harmful to a telecommunication line. Previous research on induced voltage has been focused on single-circuit lines in the distribution system. However, the double-circuit lines, referred to as parallel distribution lines, are widely used in distribution systems because they have significant economic and environmental advantages over single-circuit lines. Therefore, a study on the induced voltage in double-circuit lines is needed. This paper presents a method of calculating the induced voltage in a parallel distribution system using four-terminal parameters and vector analysis. The calculation method is verified by the Electromagnetic Transient Program (EMTP) simulation.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Stability Index Based Voltage Collapse Prediction and Contingency Analysis

  • Subramani, C.;Dash, Subhransu Sekhar;Jagdeeshkumar, M.;Bhaskar, M. Arun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.438-442
    • /
    • 2009
  • Voltage instability is a phenomenon that could occur in power systems due to stressed conditions. The result would be an occurrence of voltage collapse leading to total blackout of the system. Therefore, voltage collapse prediction is an important part of power system planning and operation, and can help ensure that voltage collapse due to voltage instability is avoided. Line outages in power systems may also cause voltage collapse, thereby implying the contingency in the system. Contingency problems caused by line outages have been identified as one of the main causes of voltage instability in power systems. This paper presents a new technique for contingency ranking based on voltage stability conditions in power systems. A new line stability index was formulated and used to identify the critical line outages and sensitive lines in the system. Line outage contingency ranking was performed on several loading conditions in order to identify the effect of an increase in loading to critical line outages. Correlation studies on the results obtained from contingency ranking and voltage stability analysis were also conducted, and it was found that line outages in weak lines would cause voltage instability conditions in a system. Subsequently, using the results from the contingency ranking, weak areas in the system can be identified. The proposed contingency ranking technique was tested on the IEEE reliability test system.

CFD Analysis on the 2nd Cylinder Discharge line in Hydrogen Reciprocating Compressor

  • Lee, Gyeong-Hwan;Woo, Ju-Sik;Shin, Yong-Han;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.695-702
    • /
    • 2010
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

전달강성계수법에 의한 직선형 구조물의 시간 이력응답 해석알고리즘에 관한 연구 (A Study on the Analysis Algorithm of Time Historical Response of Straight-line Structure by the Transfer Stiffness Coefficient Method)

  • 문덕홍;강현석;최명수
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.74-79
    • /
    • 1999
  • This paper describes formulation for algorithm of time historical response analysis of vibration for straight-line structure. This method is derived from a combination of the transfer stiffness coefficient method and the Newmark method. And this present method improves the computational accuracy of the transient vibration response analysis remarkably owing to several advantages of the transfer stiffness coefficient method. We regarded the structure as a lumped mass system here. The analysis algorithm for the time historical response was formulated for the straight-line structure containing crooked, tree type system. The validity of the present method compared with the transfer matrix method and the Finite Element Method for transient vibration analysis is demonstrated through the numerical computations.

  • PDF

전력선을 이용한 음향전달 시스템의 구성 및 특성 분석 (Analysis of Sound Transmitting System using Power line Communication Technique)

  • 김호수;이명섭;구경완;한상옥
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.128-134
    • /
    • 2004
  • 본 연구에서는 전력선통신 기술을 이용하여 전송주파수에 음성신호를 변조한 후 전력선으로 전송하고 전력선으로부터 수신 및 복조하여 변조된 음성신호를 검출하는 음향전달 시스템을 제작하였다. 제작된 시스템으로부터 변복조 및 주파수 특성을 분석하여, 어학실습 교육을 위한 용도로서의 활용 가능성을 평가하였다. 그 결과 전달된 음향 신호가 최적상태는 아니지만 어학실습 교육용으로 청취하기에 충분한 수준으로 판단되었다.

선로용량 계산 모델의 통합과 통합 민감도 분석 체계에 관한 연구 (A Study on the Integrated System and Sensitivity Analysis for Line Capacity Calculation Model)

  • 김무룡;김한신;이창호;김봉선;김동희;홍순흠
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2005년도 추계학술대회
    • /
    • pp.30-39
    • /
    • 2005
  • Line capacity calculation has been used to determine optimum efficiency and safe train service for train scheduling plan and investment priority order throughout detecting bottleneck section. Because of some problems of Yamagisi and UIC methods for line capacity calculation, developing of the method of line capacity calculation and evaluation for the Korea circumstance is important. This paper deals with the integrated system of TPS(Train Performance Simulator), PES(Parameter Evaluation Simulator), LCS (Line Capacity Simulator) and sensitivity analysis for line capacity calculation model.

  • PDF

UHF 가술을 이용한 온라인 PD 모니터링 (On-line PD Monitoring Using UHF Technique)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF