• 제목/요약/키워드: On-line monitor

검색결과 383건 처리시간 0.034초

원자력발전소에서 리스크를 고려한 작업관리 방법 (A Study on the Work Management Method Considering Risks in Nuclear Power Plants)

  • 송태영
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2014
  • Nuclear power plants(NPPs) are consisted of power production functions and safety functions preventing leakage of radiation. Operators working in NPPs shall maintain these functions during an operation period through various activities such as improvement & modification, corrective maintenance, preventive maintenance and surveillance test. According to the performance of these work activities, there are configuration changes in NPPs systems. Its changes cause the increase of safety risks(CDF) and plant trip risks. Recently, the importance of risk management is increasing gradually in the operation process of NPPs. Therefore, this paper presents the work management methods using the various risk monitoring systems during power operation and overhaul period. Also this paper suggests the optimum application ways of risk systems for work management.

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

NC 정보와 이송축 모터 전류를 이용한 선삭 가공 상태 감시 (Monitoring of Machining State in Turning by Means of Information and Feed Motor Current)

  • 안중환;김화영
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.156-161
    • /
    • 1992
  • 본 연구에서는 이송축 직류 서보 모터의 전류신호와 NC정보를 이용해서 선삭 가공상태를 감시하는 시스템을 개발하였다. 모터 전류는 가공 부하의 상태를 잘 나 타내며, NC 장치에 내장되어 있기 때문에 신호 검출을 위한 별도의 센서가 필요 없어 서 공구가 수시로 바뀌는 NC작업 감시를 위한 유효한 신호이다. 또 NC 정보로부터 작업을 예측함으로써 감시 대상을 명확히 하고 신뢰성을 높이고자 하였다. 전체적인 감시 시스템의 프로그래밍 언어로는 C를 사용하여, 실시간 감시처리를 가능하게 하였 다.

TCMS에 의한 전동차 추진/제동 제어기술의 현차시험 결과 고찰 (A Study for Running Test Result of Train Powering/Braking Control by TCMS)

  • 박성호;한정수;신광균;박계서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.652-658
    • /
    • 2000
  • TCMS(Train Control & Management System) control monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, and the software logic is verified by running test at Seoul Subway Line# 6. By running test result, we can see TCMS successfully control Powering/Braking of train

  • PDF

발효공정에서 트레할로스의 온라인 모니터링을 위한 흐름주입분석 (Flow Injection Analysis for On-line Monitoring of Trehalose in Fermentation Processes)

  • 한경아;이종일
    • KSBB Journal
    • /
    • 제22권2호
    • /
    • pp.84-90
    • /
    • 2007
  • 본 연구에서는 고가의 TreH를 형질전환한 대장균으로부터 생산하고 부분적으로 정제한 후, 에폭시에 고정화하고 트레할로스-FIA 시스템에 이용하였다. 산소 전극을 이용한 트레할로스 검출 방법과 분광학적 방법을 이용한 트레할로스 검출 방법을 비교하고, 공정에서의 온라인 모니터링의 가능성을 검토하였다. 산소 전극을 이용한 분석의 경우 다른 대사 물질로 인한 간섭현상이 상대적으로 적고 검출 가능한 농도가 0.1$\sim$1.0 g/L로 많은 량의 트레할로스를 생산하는 공정을 모니터링할 경우 적합한 시스템임을 알 수 있었다. 반면 분광학적 방법으로 트레할로스를 검출한 실험의 경우 TreH와 GOD/HRP를 고정하여 실험한 경우와 TreH만 고정하고 GOD와 HRP를 직접 주입하는 방식을 비교했을 때 검출 가능한 농도는 0.01$\sim$0.2 g/L로 낮은 농도의 트레할로스를 모니터링할 경우에 적합하다. 그러나 ABTS나 GOD, HRP의 주입량 등 경제성과 운전이 편이성 등을 고려할 경우 GOD와 HRP를 직접 주입하는 시스템이 가장 효과적임을 알 수 있었다. 이 시스템을 이용하여 소형 생물반응기 내 트레할로스의 농도를 온라인 모니터링한 결과는 오프라인 값과 매우 잘 일치함을 보였다. 생물공정에서 트레할로스의 온라인 모니터링이 FIA 기술에 의해 가능함을 확인하였다.

13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가 (Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator)

  • 선종호;황돈하;윤영호;신병철;오봉근;강동식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

카테너리 각도를 이용한 가공송전도체의 이도 추정 (Dip Estimation for Overhead Transmission Conductor using Catenary Angle)

  • 김성덕;손홍관;장태인
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.112-119
    • /
    • 2007
  • 가공송전 도체는 정상 동작조건 하에서 전력회사의 선로 설계지침에 규정된 지상고를 안정범위 내에서 항상 유지할 수 있어야 한다. 따라서 새로운 선로를 건설하거나 노화도체의 장력을 다시 조정하거나 또는 전력용량을 최대화하기 위해 동적송전용량을 모니터링하는 경우에, 도체 이도를 측정/또는 모니터링하는 것은 매우 중요하다. 본 연구에서는 도체의 카테너리 각도로 이도 및 장력을 추정하기 위한 새로운 방법을 제안한다. 가공송전선로의 대부분의 도체들은 전형적인 카테너리 곡선을 나타내므로 철탑 측의 카테너리 각도로부터 도체의 카테너리 곡선을 유일하게 결정할 수 있다. 이 카테너리 곡선을 토대로 도체의 이도나 수평장력을 쉽게 추정할 수 있다. 몇 가지 시뮬레이션과 간단한 실험 결과를 통하여 제안된 방법이 가공송전선의 도체 이도와 장력을 측정/또는 모니터링하는데 효과적으로 사용될 수 있음을 확인하였다.

상태관측기를 이용한 PMSM의 On-Line 과부하 모니터링 시스템 (Observer-Based On-Line Overload Monitoring System of PMSM)

  • 장기찬;서석훈;우광준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.268-271
    • /
    • 2001
  • This paper presents observer-based on-line overload monitoring scheme for a PMSM(Permanent Magnet Synchronous Motor) drive system. Proposed scheme is to monitor overload status of motor drive system at remote place. The drive system is previously installed on main system and has no communication function. Proposed scheme consists of intelligent sensing head and monitoring part. Intelligent sensing head acquire motor 3-Phase currents and transmit data to monitoring part over serial communication interface. Monitoring part estimates motor speed using state observer. By comparing estimated speed with reference speed, we can detect motor fault. In this scheme observed information must coded and transmitted over a digital communication channel with finite capacity. We consider communication constraint as time delay and we design discrete-time observer. The proposed scheme is tested on the actual drive system.

  • PDF

On-line Faults Signature Monitoring Tool for Induction Motor Diagnosis

  • Medoued, Ammar;Lebaroud, Abdesselem;Boukadoum, Ahcene;Clerc, Guy
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.140-145
    • /
    • 2010
  • The monitoring and the diagnosis of the faults in induction motors starting from the stator current are very interesting, since it is an accessible and measurable quantity. The spectral analysis of the stator current makes it possible to highlight the characteristic frequencies of the faults but in a wide frequency range depending on half the sampling frequency, making it very difficult to monitor on-line the faults. In order to facilitate the use of the relevant frequencies of machine faults we proposed the extraction of the frequency components using two methods, namely, the amplitude and the instantaneous frequency. The theoretical bases of these methods were presented and the results were validated on a test bench with an induction motor of 5.5 kw.