• Title/Summary/Keyword: On-line monitor

Search Result 383, Processing Time 0.036 seconds

A Study on the Work Management Method Considering Risks in Nuclear Power Plants (원자력발전소에서 리스크를 고려한 작업관리 방법)

  • Song, Tae-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • Nuclear power plants(NPPs) are consisted of power production functions and safety functions preventing leakage of radiation. Operators working in NPPs shall maintain these functions during an operation period through various activities such as improvement & modification, corrective maintenance, preventive maintenance and surveillance test. According to the performance of these work activities, there are configuration changes in NPPs systems. Its changes cause the increase of safety risks(CDF) and plant trip risks. Recently, the importance of risk management is increasing gradually in the operation process of NPPs. Therefore, this paper presents the work management methods using the various risk monitoring systems during power operation and overhaul period. Also this paper suggests the optimum application ways of risk systems for work management.

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Monitoring of Machining State in Turning by Means of Information and Feed Motor Current (NC 정보와 이송축 모터 전류를 이용한 선삭 가공 상태 감시)

  • 안중환;김화영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.156-161
    • /
    • 1992
  • In this research a monitoring system for turning using NC information and the current of feed motor as a monitoring signal was developed. The overall system consists of modules such as learning process, NC data transmission, generation of forecast information, signal acquisition, monitoring and post process. In the learning process, the reference data and the cutting force equation necessary for monitoring are obtained from the accumulated monitoring results. In the generation of forecast information, the information of forecasted cutting forces is acquired from the cutting force equation and NC program and appended to each NC block as a monitor code. Reliability of monitoring is improved by using the monitor code in the real-time monitoring. Monitoring module is divided into two parts : the off-line monitoring where errors of NC program are checked and the on-line monitoring where the level of motor current is monitored during cutting operations. If the actual current level exceeds the limit value provided by the monitor code in the level monitoring, it is recognized as abnormal. In the event of abnormal status, the post processor sends the emergency stop signal to NC controller to stop the operation. Actual experiments have shown that the developed monitoring system works well.

A Study for Running Test Result of Train Powering/Braking Control by TCMS (TCMS에 의한 전동차 추진/제동 제어기술의 현차시험 결과 고찰)

  • 박성호;한정수;신광균;박계서
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.652-658
    • /
    • 2000
  • TCMS(Train Control & Management System) control monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, and the software logic is verified by running test at Seoul Subway Line# 6. By running test result, we can see TCMS successfully control Powering/Braking of train

  • PDF

Flow Injection Analysis for On-line Monitoring of Trehalose in Fermentation Processes (발효공정에서 트레할로스의 온라인 모니터링을 위한 흐름주입분석)

  • Han, Kyung-Ah;Rhee, Jong-Il
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.84-90
    • /
    • 2007
  • Trehalose is non-reducing disaccharide which is found in bacteria, fungi, plants and insects. Trehalose has been determined by several analysis methods. To monitor the concentrations of trehalose in a process, enzymatic methods have more advantage over others, e.g. more specific. In this work, trehalase was immobilized on VA-epoxy polymer and applied to FIA systems. The behaviours of these FIA systems were characterized and used to monitor the trehalose concentrations. Use of optical detection technique was chosen for trehalose-FIA system. On-line monitoring data and off-line data were measured by HPLC.

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

Dip Estimation for Overhead Transmission Conductor using Catenary Angle (카테너리 각도를 이용한 가공송전도체의 이도 추정)

  • Kim, Sung-Duck;Sohn, Hong-Kwan;Jang, Tae-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.112-119
    • /
    • 2007
  • Under normal operating condition, the conductor of overhead transmission line could be always hold it's clearance within the safety margin that is specified in the line design guide of power company. Hence it may be very important to measure/or monitor the dip of the conductor, when building a new line, re-tensioning for an aged conductor, or monitoring dynamic line rating to maximize power capability. In this paper, we suggest a new method to estimate the dip and tension by catenary angle of the conductor. Since most conductors in overhead transmission lines show typical catenary curves, it can be uniquely determined the catenary curve for the conductor from the catenary angle at tower. Based on the catenary curve, the dip or horizontal tension can be easily estimated. Through some simulation and simple experimental results, it is verified that the suggested method can be effectively applied to measure/or monitor conductor dips and tensions in the overhead transmission lines.

Observer-Based On-Line Overload Monitoring System of PMSM (상태관측기를 이용한 PMSM의 On-Line 과부하 모니터링 시스템)

  • Jang, Ki-Chan;Suh, Suhk-Hoon;Woo, Kwang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.268-271
    • /
    • 2001
  • This paper presents observer-based on-line overload monitoring scheme for a PMSM(Permanent Magnet Synchronous Motor) drive system. Proposed scheme is to monitor overload status of motor drive system at remote place. The drive system is previously installed on main system and has no communication function. Proposed scheme consists of intelligent sensing head and monitoring part. Intelligent sensing head acquire motor 3-Phase currents and transmit data to monitoring part over serial communication interface. Monitoring part estimates motor speed using state observer. By comparing estimated speed with reference speed, we can detect motor fault. In this scheme observed information must coded and transmitted over a digital communication channel with finite capacity. We consider communication constraint as time delay and we design discrete-time observer. The proposed scheme is tested on the actual drive system.

  • PDF

On-line Faults Signature Monitoring Tool for Induction Motor Diagnosis

  • Medoued, Ammar;Lebaroud, Abdesselem;Boukadoum, Ahcene;Clerc, Guy
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.140-145
    • /
    • 2010
  • The monitoring and the diagnosis of the faults in induction motors starting from the stator current are very interesting, since it is an accessible and measurable quantity. The spectral analysis of the stator current makes it possible to highlight the characteristic frequencies of the faults but in a wide frequency range depending on half the sampling frequency, making it very difficult to monitor on-line the faults. In order to facilitate the use of the relevant frequencies of machine faults we proposed the extraction of the frequency components using two methods, namely, the amplitude and the instantaneous frequency. The theoretical bases of these methods were presented and the results were validated on a test bench with an induction motor of 5.5 kw.