GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

Chaos 이론을 이용한 부분방전 신호분석(CAPD) - 결함 종류 판별을 위한 새로운 접근 방법 (Chaotic Analysis of Partial Discharge (CAPD) - A novel approach to identify the nature of PD source)

  • 임윤석;구자윤;김성홍;이전선;최재옥;윤정훈;마지훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.975-979
    • /
    • 2001
  • In connection with the monitoring of the insulation degradation of large power apparatus in order to predict their expected service failures, a statistical treatment, such as phase resolved partial discharge analysis (PRPDA), has been established for the on-line monitoring system during the past decades. However, this method has shown some inconveniences to identify the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis (CAPD) is proposed describing the fundamental ideas, outcomes and different viewpoints from the conventional PRPDA. As a model for the possible defects causing sudden failures in service, three types of specimen are prepared. And partial discharge signals, originated from those samples, are measured and analyzed by means of CAPD. Throughout this work, it seems that the correlation between the consecutive PD pulses, depending on the nature of PD, could be clarified by CAPD. Thereffre, it could be considered that the nature of PD source can be identified more distinctively when the CAPD is combined with PRPDA.

  • PDF

발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발 (Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF

고압 회전기의 절연열화 진단을 위한 운전중 부분방전 측정 센서의 특성분석 (Characteristics Analysis of On-Line Partial Discharge Measurement Sensor for Insulation Diagnosis of HV Rotating Machines)

  • 윤대희;황돈하;김용주;이광식;김희동;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1909-1911
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines.

  • PDF

초고압 선로 부분방전 On-line 모니터링 시스템 개발 (Development of On-line PD Monitoring System for High Voltage Power Cable System)

  • 김충식;이창영;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.58-60
    • /
    • 2005
  • 초고압 선로에 대한 풍부한 진단 경험과 축적된 Know-how를 바탕으로 선로의 이상유무를 원격으로 진단, 감시하는 On-line PD Monitoring System을 개발하였다. 초고압 선로의 이상 유무를 활선상태에서 정밀하게 진단할 수 있는 전기적인 측정방법으로 부분방전이 유일하다. 그러나 부분방전 신호는 미약하고 주위 노이즈와 구분이 어렵기 때문에 측정 뿐만 아니라 분석하기가 어렵다. 부분방전 측정 장비는 이러한 노이즈를 효과적으로 제거하고 측정된 신호를 의미있는 정보로 가공하여 사용자에게 제공해 주어야 한다. 본 논문에서는 이러한 조건들을 충족하는 고성능의 원격 진단시스템에 관하여 서술하였다.

  • PDF

운전중인 대형 터빈발전기에서 절연상태 평가 (Assessment of Insulation Condition in Operating Large Turbine Generator)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

Rexonstruction of Pd Particles Supported on Silica in the Pressure of CO as Studied by Carbon-13 NMR

  • 한옥희;Gary L. Haller;Kurt W. Zilm
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권9호
    • /
    • pp.942-947
    • /
    • 1998
  • The >$^13C$ NMR spectrum of >$^13CO$ adsorbed on Pd particles varies dramatically depending on dispersion. The spectrum of highly dispersed Pd particles supported on silica is a powder pattern ∼800 ppm wide with a first moment of 410 ppm. A low dispersion sample has a motionally narrowed line centered at 750±30 ppm and only ∼85 ppm full width at half height (FWHH). Over several years, high dispersion samples show an increase in the intensity near 750 ppm. These observations are interpreted as an increase of mobile bridging CO on high dispersion Pd surfaces of particles which resulted from smoothing of the metal particle surfaces in the presence of CO.

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

뉴로-퍼지 알고리즘을 이용한 전력 설비의 열화 상태 분석 연구 (A Study on the degradation Analysis Using Neuro-Fuzzy Algorithm)

  • 황경준;이현룡;최유순;김용갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.224-226
    • /
    • 2006
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neuro-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup has generated and then has applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE O.27mmt (scratch error O.05mmt) to sample for making PD. Our new class of PD detected algorithm has also compared with previous PRPDA or Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

부분방전 신호의 누적검출과 뉴럴-퍼지 알고리즘을 이용한 컴퓨터 진단에 관한 연구 (A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal)

  • 황경준;염경태;김용갑;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1445-1446
    • /
    • 2007
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neural-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup have generated and then have applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE 0.27mmt (scratch error 0.05mmt) to sample for making PD. Our new class of PD detected algorithm have also compared with previous PRPDA or Neural Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF