• 제목/요약/키워드: On-line Condition Monitoring

검색결과 174건 처리시간 0.029초

A completely non-contact recognition system for bridge unit influence line using portable cameras and computer vision

  • Dong, Chuan-Zhi;Bas, Selcuk;Catbas, F. Necati
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.617-630
    • /
    • 2019
  • Currently most of the vision-based structural identification research focus either on structural input (vehicle location) estimation or on structural output (structural displacement and strain responses) estimation. The structural condition assessment at global level just with the vision-based structural output cannot give a normalized response irrespective of the type and/or load configurations of the vehicles. Combining the vision-based structural input and the structural output from non-contact sensors overcomes the disadvantage given above, while reducing cost, time, labor force including cable wiring work. In conventional traffic monitoring, sometimes traffic closure is essential for bridge structures, which may cause other severe problems such as traffic jams and accidents. In this study, a completely non-contact structural identification system is proposed, and the system mainly targets the identification of bridge unit influence line (UIL) under operational traffic. Both the structural input (vehicle location information) and output (displacement responses) are obtained by only using cameras and computer vision techniques. Multiple cameras are synchronized by audio signal pattern recognition. The proposed system is verified with a laboratory experiment on a scaled bridge model under a small moving truck load and a field application on a footbridge on campus under a moving golf cart load. The UILs are successfully identified in both bridge cases. The pedestrian loads are also estimated with the extracted UIL and the predicted weights of pedestrians are observed to be in acceptable ranges.

전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구 (A Study on the Monitoring System of Passive Filter to Improve Power Quality)

  • 유재근;이상익;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준
    • 정보학연구
    • /
    • 제7권4호
    • /
    • pp.61-69
    • /
    • 2004
  • 본 논문에서는 6.6kV급 고압전동기 모델 코일을 4가지의 권선의 인공적인 결함을 갖도록 제작하였다. 운전중 모의를 위해 모델 코일에 80pF의 에폭시-마이카 커플러를 설치하였으며, TGA를 사용하여 NQN, 부분방전 크기 및 부분방전 패턴 등을 측정하였다. 웨이블렛 변환기법을 이용한 고압전동기의 고정자권선의 결함에서 발생된 부분방전신호의 파형을 통하여 여러 가지의 통계적인 파라메터를 통하여 특징을 추출하였다.

  • PDF

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.

13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가 (Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator)

  • 선종호;황돈하;윤영호;신병철;오봉근;강동식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

유도성 커플러를 이용한 지하공동구의 상태감시시스템 (Implementation of condition monitoring system in underground utility tunnels using inductive coupler)

  • 주우진;김현식
    • 한국정보통신학회논문지
    • /
    • 제21권8호
    • /
    • pp.1597-1603
    • /
    • 2017
  • 지하공동구의 화재 발생 빈도는 다른 화재에 비하여 낮은 편이나 화재로 인한 피해는 경제적 손실 뿐만 아니라 사회운영 마비로 사회적 손실을 초래할 수 있다. 이에 본 논문은 지하공동구 내 설치된 누설 동축케이블을 이용하여 지하공동구의 상태감시시스템 구축에 대한 실증 시험 결과를 제시한다. 이를 위해 지하공동구에 설치된 누설 동축케이블에 삽입손실 특성이 $-6{\pm}2dB$인 유도성 커플러와 200 Mbps급 전력선 통신 모뎀을 연결하여 실증 시험한 결과, 500 m까지 IP 카메라의 송/수신을 확인하였다. 따라서 데이터 전송을 위한 통신선로의 추가 설치 없이도 지하공동구 내 설치된 누설 동축케이블을 이용하여 지하공동구에 상태감시시스템 구축이 가능할 것으로 판단된다.

Antibody Diversity 원리와 Antigen Presenting Cell을 구현한 새로운 인공 면역 시스템 (A New Artificial Immune System Based on the Principle of Antibody Diversity And Antigen Presenting Cell)

  • 이상형;김은태;박민용
    • 전자공학회논문지CI
    • /
    • 제41권4호
    • /
    • pp.51-58
    • /
    • 2004
  • 본 논문에서는 fault tolerant 하드웨어에서 가장 기본이 되는 온라인 하드웨어 테스트 시스템 구현을 위하여 새로운 인공면역 알고리즘을 제안한다. 인공 면역 알고리즘은 알려진 자기(self) 정보만을 이용하여 항체 즉 tolerance condition을 가장 최적으로 생성하는 알고리즘이다. 이를 위하여 본 논문에서는 생체 면역 시스템의 중요한 원리인 antibody diversity 원리를 적용한 새로운 tolerance condition 생성 알고리즘을 제안한다. 또한 생체 면역 시스템에서의 중요한 세포인 APC (Antigen Presenting Cell)를 Quine-McCluskey 방법으로 구현한 후 유전자 알고리즘을 통해 tolerance condition을 자동 생성하는 알고리즘을 구현한다. 이렇게 제안된 알고리즘은 FSM(Finite State Machine)의 가장 전형적인 예인 십진카운터에 적용한 후 컴퓨터 모의 실험을 통해 그 성능을 확인한다.

헐겁게 지지된 저널베어링의 마모 및 전동특성 실험적 연구 (An Experimental Study on the Wear and Vibrational Characteristics of a Loosely supported proceeding Bearing)

  • 장래혁;편성관;윤의성;공호성;최동훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.53-62
    • /
    • 2002
  • Condition monitoring plays a vital role since it sustains reliable operation of industrial plants and machinery in the pursuit of economic whole life operation. In order to achieve this goal, it is needed to monitor various parameters of mechanical system such as vibration, wear, temperature and etc., and finally to diagnosis the root causes of any possible abnormal machine condition. In this work, a machine failure caused by mechanical looseness was experimentally simulated and on-line measurement of the vibration, wear and temperature were simultaneously measured. For the quantitative analyses of machine wear, several statistical parameters of the wear particle size distribution were obtained through the center moment method of the Weibull distribution function, and they were compared to vibrational characteristics. Results showed that the wear and vibrational characteristics did not reveal a strong correlation each other in a loosely supported proceeding bearing.

  • PDF

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.