• 제목/요약/키워드: On-device analyzer

검색결과 133건 처리시간 0.026초

뇨분석 시스템 개발에 관한 연구 (A Study on the Development of Urine Analyzer System)

  • 이승진;최병철;김광년;홍순익;김재호;김재형;전계록
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.303-308
    • /
    • 1997
  • In this paper, we analyzed the spectroscopic properties of strip to analyzer urine qualitatively & quantitatively and make urine analyzer system stable by spectroscopy, and research the property of preamplifier unit. The analysis of spectroscopic properties of 10 pads in the strip is used for determine the wave length of light source of optic detector unit and used for basic materials which are necessary that we develop the algorithm analyzing the density grade of pad accurately. We make preamplifier unit by using the current to frequency method to measure the distribution of pad color. We implemented urine analyzer system. This system's hardware is composed of measuring unit for detect of distribution density of strip pad, main processing unit, communication unit, interface device, thermal printer, and indicator. The software consists of the program which manage the argument of test, proportion initial value of urine analyzer and calibrate analyzed result.

  • PDF

스트립의 컬러영상을 이용한 요 분석기에 관한 연구 (A Study on Urine Analyzer Using Color Images of Strip)

  • 조용현
    • 한국지능시스템학회논문지
    • /
    • 제17권7호
    • /
    • pp.919-923
    • /
    • 2007
  • 본 논문에서는 스트립의 컬러영상을 이용한 요 분석기의 개발을 제안하였다. 제안된 분석기에서 스트립의 컬러영상획득을 위해 이미지센서를 이용하였으며, 상이한 요성분에 반응하는 독립된 각 패드들의 영상을 한 번에 촬영하고, 촬영된 패드컬러를 분석하여 요성분의 측정값을 출력하는 특징을 가지도록 하였다. 특히 개발된 장치는 11개의 요 성분을 측정 분석하는 장치로 프로세서에 의하여 측정된 색상을 처리함으로써 복잡한 과정을 없앨 수 있어 빠른 동작과 가벼우며, 소형화되고, 가시적 판단 때보다 정확성을 매우 높일 수 있었다. 또한 유 무선의 통신인터페이스에 의하여 다른 검사기능을 가진 외부장비나 개인용 컴퓨터 및 의료기관이나 기타 요구하는 다른 곳으로 전송이 가능하도록 하였다.

ECR장치의 임피던스 매칭회로 설계 (ECR device impedance matching circuit design)

  • 김성완;김창선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.445-446
    • /
    • 2012
  • Recently the interest in wireless power transfer have been studied. ECR (Electromagnetic Coupled Resonance) device, depending on the size of the frequency characteristics of the structure, increasing in volume and larger volume of wireless power transmission device to make use of ECR is a big barrier. So to solve this problem for ECR device miniaturization and high efficiency has been actively studied. In this paper, the size of the device for ECR IM (Impedance Matching) by applying a one-turn coil circuit, remove the device in the form of ECR Network Analyzer measured by removing the one-turn coil has demonstrated the possibility of the device in the form of ECR.

  • PDF

통합 체질진단 시스템 개발 및 반복성 평가 (Development and Evaluation of Repeatability of the Integrated Constitutional Diagnosis System)

  • 전영주;김장웅;김재욱;배장한;김종열;김근호
    • 사상체질의학회지
    • /
    • 제24권3호
    • /
    • pp.34-41
    • /
    • 2012
  • Objectives In this study, we developed a mock-up of the system for Sasang Constitutional (SC) diagnosis. This system consists of 5 devices which are the face analyzer, the voice analyzer, the skin analyzer, the pulse analyzer, and the computer-based questionnaire. Our goal is to evaluate the repeatability of the system. Methods Each device is capable of classifying SC types. The classification probability of the integrated system for the SC types was obtained by summing the probability from each device. For evaluating the repeatability of the system, we collected data for 5 subjects, and repeated the measurement three times for each individual. The average and standard deviation were used for calculating the Coefficient of Variation. Results The results showed that the repeatability of the classification probability of the integrated system is about 8%, which implies the system is repeatable. Conclusions To increase usability of this system, it is desirable for the system to offer information on health condition of the user. The integrated constitutional diagnosis system will be upgraded to complement the convenience and to develop the diagnostic algorithm for the user's health condition.

열선을 이용한 혼합기체의 농도와 유량의 측정 (Measurement of Gas Concentration and flow Rate Using Hot Wire)

  • 김영한;최종정
    • 제어로봇시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

Resistance Switching Mechanism of Metal-Oxide Nano-Particles Memory on Graphene Layer

  • Lee, Dong-Uk;Kim, Dong-Wook;Kim, Eun-Kyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.318-318
    • /
    • 2012
  • A graphene layer is most important materials in resent year to enhance the electrical properties of semiconductor device due to high mobility, flexibility, strong mechanical resistance and transparency[1,2]. The resistance switching memory with the graphene layer have been reported for next generation nonvolatile memory device[3,4]. Also, the graphene layer is able to improve the electrical properties of memory device because of the high mobility and current density. In this study, the resistance switching memory device with metal-oxide nano-particles embedded in polyimide layer on the graphene mono-layer were fabricated. At first, the graphene layer was deposited $SiO_2$/Si substrate by using chemical vapor deposition. Then, a biphenyl-tetracarboxylic dianhydride-phenylene diamine poly-amic-acid was spin coated on the deposited metal layer on the graphene mono-layer. Then the samples were cured at $400^{\circ}C$ for 1 hour in $N_2$ atmosphere after drying at $135^{\circ}C$ for 30 min through rapid thermal annealing. The deposition of aluminum layer with thickness of 200 nm was done by a thermal evaporator. The electrical properties of device were measured at room temperature using an HP4156a precision semiconductor parameter analyzer and an Agilent 81101A pulse generator. We will discuss the switching mechanism of memory device with metal-oxide nano-particles on the graphene mono-layer.

  • PDF

Building a Dynamic Analyzer for CUDA based System.

  • SALAH T. ALSHAMMARI
    • International Journal of Computer Science & Network Security
    • /
    • 제23권8호
    • /
    • pp.77-84
    • /
    • 2023
  • The utilization of GPUs on general-purpose computers is currently on the rise due to the increase in its programmability and performance requirements. The utility of tools like NVIDIA's CUDA have been designed to allow programmers to code algorithms by using C-like language for the execution process on the graphics processing units GPU. Unfortunately, many of the performance and correctness bugs will happen on parallel programs. The CUDA tool support for the parallel programs has not yet been actualized. The use of a dynamic analyzer to find performance and correctness bugs in CUDA programs facilitates the execution of sophisticated processes, especially in modern computing requirements. Any race conditions bug it will impact of program correctness and the share memory bank conflicts to improve the overall performance. The technique instruments the programs in a way that promotes accessibility of the memory locations accessed by different threads well as to check for any bugs in the code of a program. The instrumented source code will be used initiated directly in the device emulation code of CUDA to send report for the user about all errors. The current degree of automation helps programmers solve subtle bugs in highly complex programs or programs that cannot be analyzed manually.

반사광을 이용한 다채널 임상화학분석기개발 (Development of a multi-channel clinical chemistry analyzer)

  • 유동주;송은영
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.139-148
    • /
    • 1995
  • In this paper we report the device of a multi-channel clinical instrument developed for determi¬nation of the levels of the urinary urobilinogen, glucose, ketone, bilirubin, protein, ascorbic acid, nitrite, pH, occult-blood, specific gravity, and leukocytes semiquantitatively. The test parameters are expressed on the dry test strips as a range of color intensities by chemical reactions. The instrument measures the value of each substance by reading the reflectance light emanated from the test strips. We also designed the reagent strip cassette and loader in order to intercept the outside interference. The loader can be operated semi-automatically. The light source is consisted on light emitting diodes at three specific wavelengths (560 nm, 610 nm, 650 nm). Precision of the system was evaluated by testing a series of commercial control urine samples. Furthermore, the performance of the instrument was compared with two other test methods on the urine samples from 100 persons. Our results showed a good repeatability between tests and a satisfactory agreement between the readings by our instrument and visual evaluation.

  • PDF

DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델 (High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter)

  • 신주현;김우중;차한주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.

유도성 리액턴스 변화를 이용한 VCO의 설계 및 동작 연구 (A Design and Performance Investigation of VCO using Inductive Reactance Variation)

  • 오세환;서석태;구경완;이원희;허정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.405-408
    • /
    • 2000
  • We designed and fabricated VCO using inductive reactance variation at 2GHz. A varactor diode is one of the main devices in VCO, which varies capacitance depending on reverse voltage. In this paper, a varactor diode is not used as a variable capacitive reactance device but as an inductive device. The circuit design and simulation have been carried out using HP-MDS. The fabricated VCO is measured using the HP 8532B spectrum analyzer and the HP 4352B VCO/PLL analyzer. The experimental result shows the phase noise -110dBc/Hz at a 100kHz offset frequency, the control voltage sensitivity of 23MHz/V and a -3.5dBm output power with a D.C. current consumption of 5.9mA. The simulation and measurements show exact agreement except with regard to the oscillation frequency. The measured oscillation frequency is lower than the simulation result because there is some parasitic inductance in the PCB layout.

  • PDF