Effective 3-D FEM for large-scale high temperature superconducting racetrack coil

  • Huang, Xiangyu;Huang, Zhen;Xu, Xiaoyong;Li, Wan;Jin, Zhijian
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.32-37
    • /
    • 2019
  • In various types of large-scale electrical applications, the number of coil turns in such machines is usually large. Electromagnetic simulation of large-scale superconducting coils (tens to hundreds of turns) is indispensable in the design process of superconducting electrical equipment. However, due to the large scale of the coil and the large aspect ratio of super-conducting material layer in HTS coated conductor, it is usually difficult or even unable to perform 3-D transient electromagnetic simulation. This paper introduces an effective 3-D electromagnetic simulation method for large-scale HTS coated conductor coil based on T-A formulation. The simulation and experimental results show that the 3-D model based on the T-A formulation using homogeneous strategy is more accurate than the traditional 2-D models. The memory usage is not sensitive to the number of turns and this model will be even more superior as the number of turns becomes larger.

Breakdown Properties of Coolant for HTS Apparatus Operating at Cryogenic Temperature

  • S.M. Baek;J.M. Joung;Kim, S.H
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.52-55
    • /
    • 2003
  • For the dielectric insulation design of any high temperature superconducting (HTS) apparatus in the electrical power systems, the breakdown properties of cryogenic coolants such as $LN_2$ are an important factor of the insulating engineering. Therefore, this paper presented an experimental investigation of breakdown phenomena in $LN_2$ under AC voltage. And we studied the breakdown properties of LN2 with decreasing temperature. Also, the Weibull plots of the breakdown voltage of subcooled $LN_2$ at 65 K for the needle-plane electrode with electrode distance d= 10 mm are studied. The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated. The experimental data suggested that the breakdown voltage of L$N_2$ depend strongly on the temperature of $LN_2$. The breakdown characteristics of $LN_2$ under quasi-uniform and non-uniform electrical field for temperature ranging from 77 K to 65 K were clarified.

식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성 (Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil)

  • 안정식;심명섭;정중일;김남렬;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF

코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성 (Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters)

  • 손창효
    • 한국가스학회지
    • /
    • 제11권3호
    • /
    • pp.44-48
    • /
    • 2007
  • 본 연구는 코일직경변화에 따른 헬리컬 코일 가스냉각기내 초임계 $CO_2$의 냉각 열전달 특성에 대해 실험적으로 조사하였다. 냉매 순환루프의 주요구성품은 수액기, 변속펌프, 질량유량계, 예열기, 헬리컬 코일형 가스냉각기(시험부)로 구성된다. 시험부는 내경 4.55 mm의 평활 동관과 26.75 mm와 41.35 mm인 코일직경으로 이루어져 있다. 냉매질량유속은 $200kg/m^2s$에서 $800kg/m^2s$가지 변화시켰고, 가스냉각기의 입구압력 범위는 7.5 MPa에서 10.0 MPa까지이다. 코일직경이 26.75 mm인 가스냉각기내 이산화탄소의 냉각열전달 계수가 코일직경이 41.35 mm인 열전달 계수보다 높은 것으로 나타났다. 또한 초임계 상태에서 제안한 종래의 냉각 열전달 상관식과 비교한 결과, 대부분의 상관식이 과소예측되었고, 그 중에서도 이산화탄소의 냉각 열전달 계수는 Pilta 등이 제안한 상관식과 좋은 일치를 보였다. 하지만, 유사임계 온도 영역부근에서는 실험데이터가 더 큰 것으로 나타났다.

  • PDF

이온 窒化된 SW3코일 스프링의 疲勞擧動에 관한 硏究 (Study on the Fatigue Behavior of Ion-Nitrided SW3 Coil Spring)

  • 염영하;장성대
    • 대한기계학회논문집
    • /
    • 제7권4호
    • /
    • pp.355-360
    • /
    • 1983
  • This paper deals with fatigue behavior of ion-nitrided coil spring. It is found that fatigue limit can be significantly increased by ion-nitriding. Ion-nitribed specimen which is treated at 550.deg. C for 5 hours improves in the fatigue limit by 30 percent in comparison with that of non-nitrided specimen. On the other hand, the value of spring constant K has nothing to do with nitriding time and temperature in this experimental range. Besides fatigue behavior, the following effects are discussed such as compound layer, diffusion layer, hardness distribution and their relations.

Correlation between Coil Configurations and Discharge Characteristics of a Magnetized Inductively Coupled Plasma

  • Cheong, Hee-Woon
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.222-228
    • /
    • 2016
  • Correlation between coil configurations and the discharge characteristics such as plasma density and the electron temperature in a newly designed magnetized inductively coupled plasma (M-ICP) etcher were investigated. Radial and axial magnetic flux density distributions as well as the magnetic flux density on the center of the substrate holder were controllable by placing multiple circular coils around the etcher. The plasma density increased up to 60.7% by arranging coils (or optimizing magnetic flux density distributions inside the etcher) properly although the magnetic flux density on the center of the substrate holder was fixed at 7 Gauss.

나선코일 튜브 내에서의 압력손실에 관한 연구 (A Study on the Pressure Loss in Helically Coiled Tubes)

  • 한규일;박종운
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF

인버터 서지와 온도스트레스 하에서 PAI/Nano Silica 에나멜와이어의 가속절연수명 평가 (Accelerated Insulation Life Estimation for PAI/Nano Silica Enamelled Wire under Inverter Surge and Temperature Stress)

  • 박재준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1712-1720
    • /
    • 2016
  • AC and DC insulation breakdown voltage was studied for magnet wire coated with double layers of high flexural PAI layer and high anti-corona PAI/nanosilica (15 wt%) layer. The specimens were prepared at various drying temperatures (T/D): $22^{\circ}C$, $240^{\circ}C$, and $260^{\circ}C$, respectively. The increase effects of nanosilica on AC and DC insulation breakdown voltage were not so significant compared to that of magnet wire coil coated with original PAI. And the AC and DC insulation breakdown voltage was improved by decreasing diameter of winding coil. As T/D temperature increased, AC and DC insulation breakdown voltage decreased.

전자기식 교반법을 이용한 입자강화형 금속복합재료의 제조 및 Thixoforming을 위한 재가열 공정 (Fabrication of Particulates Reinforced Metal Matrix Composites by Electro-Magnetic Stirring and Reheating Process for Thixoforming)

  • 임해정;강충길;조형호
    • 소성∙가공
    • /
    • 제9권5호
    • /
    • pp.494-503
    • /
    • 2000
  • The electro-magnetic stirring and mechanical process were applied to fabricate particulate metal matrix composites(PMMCs) with various particle size. The mechanical test on PMMCs was carried out in order to clarify the effect of 76 heat treatment on tensile behaviors. In order to study the thixoforming of PMMCs, fabricated billet are reheated by using the coil designed as a function of length between PMMC billet and coil surface, coil diameter and billet length. The effect of reinforcement distribution on billet temperature variation has been investigated with the calculated solid fraction theory based on a function of matrix alloy and volume fraction of reinforcement.

  • PDF

50 kVA 주상용 몰드변압기의 설계 및 특성평가 (The Design and Performance Test of Mold Transformer for Outdoor Pole)

  • 조한구;이운용;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF