• Title/Summary/Keyword: On-board facility design

Search Result 17, Processing Time 0.023 seconds

Design and Implementation of 30" Geometry PIG

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.629-636
    • /
    • 2003
  • This paper introduces the developed geometry PIG (Pipeline Inspection Gauge), one of several ILI (In-Line Inspection) tools, which provide a full picture of the pipeline from only single pass, and has compact size of the electronic device with not only low power consumption but also rapid response of sensors such as calipers, IMU and odometer. This tool is equipped with the several sensor systems. Caliper sensors measure the pipeline internal diameter, ovality and dent size and shape with high accuracy. The IMU (Inertial Measurement Unit) measures the precise trajectory of the PIG during its traverse of the pipeline. The IMU also provide three-dimensional coordination in space from measurement of inertial acceleration and angular rate. Three odometers mounted on the PIG body provide the distance moved along the line and instantaneous velocity during the PIG run. The datum measured by the sensor systems are stored in on-board solid state memory and magnetic tape devices. There is an electromagnetic transmitter at the back end of the tool, the transmitter enables the inspection operators to keep tracking the tool while it travels through the pipeline. An experiment was fulfilled in pull-rig facility and was adopted from Incheon LT (LNG Terminal) to Namdong GS (Governor Station) line, 13 km length.

Design of Self-Powered Sensor System for Condition Monitoring of Industrial Electric Facilities (산업전기 설비의 상태 감시를 위한 자가 발전 센서 시스템의 설계)

  • Lee, Ki-Chang;Kang, Dong-Sik;Jeon, Jeong-Woo;Hwang, Don-Ha;Lee, Ju-Hun;Hong, Jeong-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.264-266
    • /
    • 2005
  • Recently, on-line diagnosis methods through wired and wireless networks are widely adopted in the diagnosis of industrial Electric Facilities, such as generators, transformers and motors. Also smart sensors which includes sensors, signal conditioning circuits and micro-controller in one board are widely studied in the field of condition monitoring. This paper suggests an self-powered system suitable for condition-monitoring smart sensors, which uses parasitic vibrations of the facilities as energy source. First, vibration-driven noise patterns of the electric facilities are presented. And then, an electromagnetic generator which uses mechanical mass-spring vibration resonance are suggested and designed. Finally energy consumption of the presented smart sensor, which consists of MEMS vibration sensors, signal conditioning circuits, a low-power consumption micro-controller, and a ZIGBEE wireless tranceiver, are presented. The usefulness and limits of the presented electromagnetic generators in the field of electric facility monitoring are also suggested.

  • PDF

An Analysis on the Relationship between the Art Elements and Preference of Urban Street Furnitures (도시 가로시설물의 조형 요소와 선호도 간의 상관성 분석)

  • Kang, Gui-Bum;Cho, Se-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.4
    • /
    • pp.10-20
    • /
    • 2014
  • This study was carried out for the purpose of analysis correlations between street furniture design elements and preference of street furniture. This research analyzed the various street furniture set on Ilsan new town street, which are rest, hygiene, light, information, sale, traffic, and landscape. This study has processed by analysing street furniture literature investigation and consideration of theory. First, for analysed effect of street furniture element, has been appear as element 'relaxation facilities', 'information facilities', landscape facilities' mainly effect on street. Specially, 'rest', 'landscape', 'information' in order had a major influence on scenery. Each kind of 'chair elements' in rest facilities, 'sign board' in information facilities, 'sculpture', 'fountain' in 'landscape facilities' has analyzed as the main elements in the landscape affinity property affecting factor. Second, the results of analyzed landscape elements (shape, colour, texture, scale) affect to the affinity of street furniture. chair which are included in rest facilities affect "texture", "form", "scale", "color" in the order of preference of the molding design elements that influence landscape. Particularly, showed statistically significant on 'colour' element affecting the landscape preference than the other three elements. It means as the chair element which is rest facilities mainly affect on preferences, rather than texture, form, scale, colour. Monument in the landscape associated with a preference 'colour', 'shape', 'texture' 'scale' and appears to be in order of impact so we could get the consequence like chair and rest facilities show different aspects of the respectively. It means, visual element which are colour and shape significantly impact on landscape preferences. Third, information facilities such as signboard formative elements of landscape design preferences and correlation with negative showed that the correlation. That mean if the sign board is very negative influence on landscape preferences and the correlations of the design formative elements appear in order of 'scale', 'colour', 'texture'. It also means that the 'scale' namely the size of advertising material and colour are adversely affected in terms of landscape. As these results, when design street furniture as the street scenery, facilities according to the kind of the shape element and need to focus on relative shape element according to the kind of facilities difference. Finally, so far as to clarify the street furniture, mainly 'function' and 'system' classification shows undesirable in outdoor scape. Thus, performed studies in relationship with landscape, classify 'kind of facilities' is more desirable than 'system'.

Security Problem of National Major Facility's Parking Lot and its Improvement Method -Focused on Doonchi(Waterside) Parking Lot of National (국가중요시설의 주차장 보안의 문제점과 개선방안: 국회둔치주차장을 중심으로)

  • Lee, Sang-Hun;Lee, Sang-Yeol
    • Korean Security Journal
    • /
    • no.50
    • /
    • pp.61-87
    • /
    • 2017
  • National Assembly is a constitutional institution that is required to first consult the will of the people and it should do its effort continuously so that security of citizens using parking lot would be enhanced at the same time while improving parking service in order to increase customer satisfaction of the people. Under this recognition, in this study, Doonchi parking lot of National Assembly under consigned management was first reviewed in a perspective of criminal prevention through environmental design(CPTED) and particularly, fence installation and reinforcement work for securing 'territoriality' and operation of all round shooting camera and installation of No-trespassing warning board at entrance were suggested. Second, it was recommended to change independent control system in which CCTV security system of National Assembly Doonchi parking lot is operated separately from National Assembly safety situation room and integrate it with National Assembly safety situation room(revised to double safety system) and performance of CCTV camera was made to be increased to over 2m. In addition, video recording mode was converted to NVR mode for application to IP camera in the future and in order to avoid dead zone of security monitoring area and based on site inspection result, addition 3 places of newly installing CCTV were indicated. Third, it was recommended to introduce parking fare billing and management system through unmanned equipment in parking lot management and operation.(specialized management of professional parking service provider was reviewed). By doing so, risk of cash handling by charging personnel was removed by reducing current 7 working personnel to 3 and particularly, by converting parking lot management mode being operated temporarily from 9 A.M. to 9 P.M. at present to 24 hours operation mode and providing more specialized parking service, citizens visiting National Assembly were provided with convenience and image of National Assembly was also enhanced. This study was carried out in parallel with various literature and case studies, including data from the Office of the Defense Protection in the National Assembly.

  • PDF

The Changing Pattern of Physical and Psychological Health, and Maternal Adjustment Between Primiparas Who Used and Those Who did Not Use Sanhujori Facilities (산후조리원 이용여부에 따른 초산모의 신체적, 심리적 건강상태 및 모성역할적응의 변화양상에 관한 연구)

  • Song, Ju-Eun;Park, Bo-Lim
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.4
    • /
    • pp.503-514
    • /
    • 2010
  • Purpose: The purpose of this study was to compare levels of postpartum fatigue, depression, childcare stress, and maternal identity according to postpartum period between primiparas who used Sanhujori facilities and those who did not. Methods: The research design was a longitudinal descriptive study using self-report questionnaires. Participants were 55 healthy primiparas who delivered at one of 3 hospitals in Chungnam, 21 using Sanhujori facilities and 34 not using these facilities during the first three weeks after childbirth. Data were collected from October 2008 to April 2009 at three measurement points, 2-4 days after childbirth (T1), 4-6 weeks (T2), and 12-14 weeks (T3). Data were analyzed using the SPSS 17.0 WIN program. Results: There was a significant difference in childcare stress between the two groups at 4-6 weeks after childbirth. Postpartum depression and childcare stress at 4-6 weeks were significantly higher than those of the other postpartum periods, while maternal identity was significantly lower. Conclusion: Child care stress is the most important issue among women who use Sanhujori facilities and the 4-6 week period after childbirth is very difficult to primiparas. These results indicate that nursing interventions for primiparas in Sanhujori facilities should focus on reducing childcare stress. Furthermore proper follow-up programs at 4-6 weeks are needed to decrease the difficulties in adjustment by new mothers.

Development of Configuration Management Methodology for Rocket Development Test Facilities (발사체 개발 시험시설의 형상관리 방법론 개발)

  • Jeon, Chanmin;Choi, Minchan;Park, Taekeun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.3
    • /
    • pp.31-41
    • /
    • 2023
  • This study is a study to develop a configuration management methodology for efficient and systematic management in the event of configuration changes such as deformation, explosion, and remodeling of launch vehicle development test facilities, which are emerging as important national facilities in the era of full-scale space competition. Through the analysis of international standards for configuration management, a configuration management process framework to be applied to launch vehicle development test facilities is extracted, a survey was conducted on experts who performed life cycle engineering of launch vehicle development test facilities, and a configuration management methodology optimized for operation/management of domestic launch vehicle development test facilities was proposed. Identify the configuration for launch vehicle development test facilities, the configuration management manager, configuration management organization, and configuration management board approve/process the configuration changes, and after construction is completed according to design requirements, launch vehicle development test facilities try to manage the configuration in a controlled state.

Comparison on the Performance of Soil Improvement in Thick Soft Ground Using Single-Core and Double-Core PBD (단일 및 이중 코어 PBD에 의한 대심도 연약지반 개량 효과에 관한 비교연구)

  • Yang, Jeong-Hun;Hong, Sung-Jin;Kim, Hyung-Sub;Lee, Woo-Jin;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.33-45
    • /
    • 2009
  • The conventional single-core PBDs have been widely used in order to accelerate consolidation settlement of soft grounds. When using the single-core PBD in a thick clay deposit, a delay of consolidation may occur due to high confining pressure in the thick deposit and necking of drains. This study is to compare the performances of soil improvement by the single-core and double-core PBD installed at a site in Busan New Port which exhibits approximately a 40m-thick clay layer. An in-situ test program was performed at the test site where a set of the double-core PBDs and single-core PBDs were installed to compare the efficiency of each drain. In addition, the discharge capacity of each PBD has been measured using the modified Delft Test. A series of laboratory tests for estimating in-situ soil properties have also been performed in order to obtain input parameters for a numerical program ILLICON. The discharge capacity of the double-core PBD is higher than that of the single-core PBD in the modified Delft Test. However it is observed from the comparative in-situ test and numerical analysis that there is no difference in the performance of ground improvement between the two drain systems. This discrepancy comes from the fact that the amount of water released during consolidation in most common field conditions is much smaller than the capacity of even the single core PBD. And thus, considering actual field conditions, it can be concluded that the single-core PBD has enough discharge capacity even in the thick clay deposit such as this test site.