• Title/Summary/Keyword: On pump conversion

Search Result 51, Processing Time 0.026 seconds

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

열교환기에서 부식이 열전달에 미치는 영향에 관한 연구 (A Study of The Effect of Corrosion on Heat Transfer in a Heat Exchanger)

  • 권현민;권정태
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.227-232
    • /
    • 2019
  • 심층수와 표층수의 온도 차이를 이용하는 히트펌프 시스템이나 해수열원 발전시스템(OTEC)의 열교환기는 해수의 염분에 의하여 발생하는 열교환기의 표면 위에서의 부식 현상에 의하여 열전달 성능이 저하된다. 본 연구는 이중관식 열교환기 실험을 통하여 부식시간에 따른 열전달저하를 실험하고 분석한 내용을 제시한다. 이러한 연구는 고가의 티타늄 열교환기를 대체하기 위하여 알루미늄에 전착 코팅을 하여 제작된 코팅 관을 통해 수행되었다. 코팅 두께 10, 15, $20{\mu}m$의 알루미늄 관 및 티타늄 관을 각각 6주, 12주, 18주씩 가속 부식시킨 후에 이중관 열교환기 실험을 통하여 코팅 두께 및 부식 시간에 따른 열전달의 변화를 측정하고 분석하였다. 코팅이 얇을수록 더 빠르게 블리스터 현상이 발생하였다. $15{\mu}m$의 코팅 관의 경우 12주 부식까지는 좋은 열전달 성능을 보였으나, 18주 부식의 경우에서 열전달 성능의 감소를 보였다. 연구결과로부터 본 실험 조건에서는 $20{\mu}m$의 두께로 코팅된 알루미늄관이 티타늄을 대체할 수 있는 열전달 성능을 가질 수 있음을 확인하였다. 또한, 부식 시간에 따른 부식 열저항의 증가에 대한 고찰을 통하여 향후 부식 열저항 모델 개발의 방법론을 제시하였다.

Mid-Term Results of Minimally Invasive Direct Coronary Artery Bypass Grafting

  • Seo, Dong Hyun;Kim, Jun Sung;Park, Kay-Hyun;Lim, Cheong;Chung, Su Ryeun;Kim, Dong Jung
    • Journal of Chest Surgery
    • /
    • 제51권1호
    • /
    • pp.8-14
    • /
    • 2018
  • Background: Minimally invasive direct coronary artery bypass grafting (MIDCAB) has the advantage of allowing arterial grafting on the left anterior descending artery without a sternotomy incision. We present our single-center clinical experience of 66 consecutive patients. Methods: All patients underwent MIDCAB through a left anterior small thoracotomy between August 2007 and July 2015. Preoperative, intraoperative, postoperative and follow-up data - including major adverse cardiovascular and cerebrovascular events (MACCE), graft patency, and the need for re-intervention - were collected. Results: The mean age of the patients was $69.4{\pm}11.1years$ and 73% were male. There was no conversion to an on-pump procedure or a sternotomy incision. The 30-day mortality rate was 1.5%. There were no cases of stroke, although 2 patients had to be re-explored for bleeding, and 81.8% were extubated in the operating room or on the day of surgery. The median stay in the intensive care u nit and in the hospital were 1.5 and 9.6 days, respectively. The median follow-up period was 11 months, with a 5-year overall survival rate of $85.3%{\pm}0.09%$ and a 5-year MACCE-free survival rate of $72.8%{\pm}0.1%$. Of the 66 patients, 32 patients with 36 grafts underwent a postoperative graft patency study with computed tomography angiography or coronary angiography, and 88.9% of the grafts were patent at $9.7{\pm}10.8months$ postoperatively. Conclusion: MIDCAB is a safe procedure with low postoperative morbidity and mortality and favorable mid-term MACCE-free survival.

에너지 절감형 항온항습기 운전 특성에 관한 연구 (Study on the energy-saving constant temperature and humidity machine operating characteristics)

  • 차인수;하민호;정경환
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 연구에서 적용한 열회복 방식은 적은 동력사용으로 최대의 냉각능력을 낼 수 있는 에너지 절약형이다. 항온항습기의 온습도를 보다 정밀 한 제어 기능을 갖도록 하기 위해 제어 알고리즘은 퍼지 PID 제어기를 설계하여 적용하였고, 외기보상장치(공냉식)를 갖추어 동절기에 $-20^{\circ}C$에서도 우수한 제습능력을 발휘하게 하였다. 고효율, 저소음형 시로코 팬을 채용하여 정숙운전이 되며 장비특성에 따라 상향식과 하향식에 맞도록 설계하였다. 실험한 결과 변환 효율은 95%이상, 정전복귀는 5sec 이내, 정지지연은 30sec 이내, 펌프다운은 10sec, 펌프지연은 5sec, 히팅지연은 5sec, 온도편차는 ${\pm}2^{\circ}C$(냉방편차: $2^{\circ}C$, 난방 편차: $2^{\circ}C$), 습도편차는 ${\pm}5%$(가습편차 3.0%, 제습편차 3.0%)을 갖게 하였다. 최근 유비쿼터스 기술이 중요시 되고 있기에 핸드폰을 통해 항온항습기를 원격 제어 할 수 있도록 하였고, MMI 소프트웨어와 자동 인터페이스를 지원하여 확장성이 뛰어나게 하였다. 또한 지능형 컨트롤러 고장진단에 의한 부품 및 장비의 수명이 연장 되도록 하였다.

200 Gbps WDM 시스템에서 Mid-Span Spectral Inversion 기법을 이용한 채널 왜곡의 보상 특성 (Compensation Characteristics of Distorted Channels in 200 Gbps WDM Systems using Mid-Span Spectral Inversion Method)

  • 이성렬
    • 한국전자파학회논문지
    • /
    • 제14권8호
    • /
    • pp.845-854
    • /
    • 2003
  • 광섬유의 색 분산과 비선형 효과에 의해 왜곡된 채널 신호를 보상하기 위한 방법으로 고비선형 분산 천이 광섬유의 광 위상 공액기를 이용한 경로 평균 강도 근사 MSSI(Mid-Span Spectral Inversion)를 채택한 채널 전송률 40 Gbps의 5-채널 WDM시스템의 시뮬레이션을 통하여 채널 각각의 MSSI 보상 특성을 다양한 광섬유 분산 계수에 따라 분석해 보았다. 채널별 보상 특성의 분석은 1 dB 기준 눈 열림 패널티, 수신단에서의 비트 에러율 특성, $10^{-9}$ BER에서의 채널 간 파워 패널티 등을 이용했다. 시스템 전송 길이, 광섬유의 분산 계수, 광 위상 공액기 펌프 광 파장, 광 위상 공액기에서의 WDM신호 파장에 따른 공액파 변환 효율 등에 관계하여 광 위상 공액기를 중심으로 한 첫 번째 전송 링크에서의 신호 평균 전력과 두 번째 전송 링크에서의 공액파 평균 전력을 동일하게 만드는 펌프 광 전력을 적절히 선택하면 고비선형 분산 천이 광섬유가 MSSI 보상을 통한 광대역 WDM 시스템을 위한 광 위상 공액기에서의 비선형 매질로 매우 적합하다는 것을 확인할 수 있었다.

유압동력 발생장치의 소음특성 개선을 위한 실험적 연구 (An experimental study on the improving noise characteristic of hydraulic power unit)

  • 이기천;이용범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.638-643
    • /
    • 2013
  • 유압시스템의 출력밀도를 높이기 위해 고압화, 대형화 되고 있으나, 유압동력 발생장치(HPU)를 구동할 때 110 dB(A) 정도의 높은 소음이 발생한다. 최근 산업안전규제 강화와 작업장 환경개선 요구 등으로 인하여 HPU의 소음저감을 위한 방안으로 실외나, 지하에 별도의 설치공간을 만들어 HPU를 이용하는 경우가 있었으나, 배관에서의 작동유 유동마찰로 인한 동력손실과 고장 났을 때 신속하게 대응하는데 문제가 있었다. 본 연구에서는 HPU의 동력변환 과정에서 필수적으로 발생되는 소음을 효과적으로 차폐시키면서 동력손실을 저감시키는 방음챔버(chamber)를 채용하여 소음특성을 개선하는 연구를 실험적으로 하였다.

수포화 암석코어의 상온 전기비저항 모니터링 (Resistivity Monitoring of Saturated Rock Cores at Room Temperature)

  • 이상규;이태종;이명종
    • 지구물리와물리탐사
    • /
    • 제18권3호
    • /
    • pp.105-114
    • /
    • 2015
  • 상온 상습 환경에서 수포화 암석코어의 전기비저항을 장시간 모니터링 할 수 있는 장치를 구현하였다. 양쪽 금속망 전극에 덧댄 종이필터와 암석코어를 감싼 열수축튜브의 상부 중앙 외피면에 3-채널 펌프로 물을 충분히 공급하면서 전기저항을 측정하면 암석코어의 수포화 상태를 유지하면서 일주일 이상 전기비저항을 모니터링 할 수 있다. 이 장치를 이용하여 흑운모 편마암, 안산암질 응회암, 셰일의 3종류 암석코어의 수포화 전기저항을 9일간 모니터링 한 결과 다음과 같은 2가지 가설을 제시할 수 있었다. 즉, 전기비저항 온도계수의 수렴 속도는 열물성과 관련이 있을 것이라는 것과 건조 저항을 수포화 때의 평균 저항으로 나눈 건조/수포화 저항비는 유효공극률과 상관될 것이라는 것이다. 실제로, 3가지 암석의 건조/수포화 저항비는 각각 48, 705, 2로 나타났고 이때 각각의 유효공극률은 3.7%, 3.3%, 13.0%이었다.

폐쇄형 해양온도차발전 사이클에 관한 연구 (A Study of Closed OTEC Power Plants)

  • 신상호;정동수;김종보;서태범;천원기;오정무
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.23-33
    • /
    • 1997
  • 본 연구에서는 Rankine 사이클을 이용한 해양 온도차 발전 시스템을 컴퓨터로 모사했고 작동유체를 변화시켜 가면서 그 성능을 비교하였다. 증발기와 응축기는 UA(총괄열전달계수$\times$전열면적)와 LMTD(대수평균온도차) 방법으로 모사하였으며 터빈과 펌프는 등엔트로피 효율로 모사하였다. 작동유체로는 R22, R290, R1270, R134a, R125, R143a, R32, R410A 그리고 암모니아 등을 사용하였다. 모사 결과 OTEC 발전 시스템의 효율은 작동유체에 상관없이 거의 일정한 것으로 드러났다. 한편 증발기 출구에서의 과열도와 응축기 출구에서의 과냉도는 시스템의 성능에 거의 영향을 미치지 않는 것으로 나타났지만 터빈의 효율과 열교환기의 크기는 시스템 성능에 큰 영향을 미치는 것으로 나타났다. 마지막으로 따뜻한 표층수와 차가운 심해수 사이의 온도차가 $20^{\circ}C$이상일 때 실제로 전기를 생산할 수 있다는 사실을 확인했다.

  • PDF

화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치 (Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system)

  • 홍지석;정원철;김현진;이민재;정대성;전창수;성홍계;신석재;남석우
    • 한국항공우주학회지
    • /
    • 제41권3호
    • /
    • pp.226-232
    • /
    • 2013
  • 소형 무인항공기의 동력장치로 연료전지 시스템을 적용하기 위해 화학수소화합물 수소 저장방법을 이용한 소형 수소 발생 제어장치를 설계하였다. 효율이 높은 소형/경량 수소 발생 제어장치를 설계하기 위하여 $NaBH_4$ 수용액 공급 유량에 따른 Co-B 촉매의 수소 전환율을 확인하였고, 100W 스택의 최대 수소 발생량에 적합한 Co-B 촉매양을 제안하였다. 효율적인 연료 소모를 위해 Dead-end 방식의 스택을 선택하였고, 수소 발생 제어장치 내부 압력을 이용한 펌프 on/off 제어로 수소 생성량을 제어하였다. 소형 수소 발생 제어장치를 이용한 연료전지 시스템의 각 작동구간에서 안정된 운전을 확인하였다. 장시간 운전 실험을 통하여 최대 7시간 운전이 가능하며, 임의의 비행 프로화일에 요구되는 추력 프로화일은 최소 4시간 이상 조정 가능함을 확인하였다.

Er3+, Yb3+ 이온이 동시 도핑된 NaGd(MoO4)2의 업컨버젼 분석 (Upconversion luminescence from poly-crystalline Yb3+, Er3+ co-doped NaGd(MoO4)2 by simple solid state method)

  • 강석현;강효상;이희애;심광보
    • 한국결정성장학회지
    • /
    • 제26권4호
    • /
    • pp.159-163
    • /
    • 2016
  • 본 연구에서는 간단 고상합성법(solid state reaction method)을 이용하여 $Yb^{3+}$, $Er^{3+}$ 이온이 동시도핑된 $NaGd(MoO4)_2$ ($NaGd(MoO_4)_2:Yb^{3+}/Er^{3+}$)를 성공적으로 합성하였으며, 결정구조 및 광학적 특성을 면밀히 분석하였다. 980nm의 근적외선 레이저를 합성된 NaGd(MoO4)2 파우더에 조사하였을 때 $NaGd(MoO_4)_2:Yb^{3+}/Er^{3+}$ 분말은 540 및 550 nm 부근에서 강한 녹색 발광과 함께 650 및 670 nm 부근에서의 매우약한 적색 발광을 하였으며 이러한 업컨버젼 발광 현상은 $Er^{3+}$ 이온 내의 infra 4f transition에 의한 현상임을 확인할 수 있었다. 또한, $Yb^{3+}$$Er^{3+}$ 이온의 최적 도핑 농도는 각각 (10.0/10.0 mol%)로 확인되었으며, 그에 따른 upconversion 발광 메커니즘에 대하여 상세히 논의하였다.