• Title/Summary/Keyword: On Line Maintenance

Search Result 629, Processing Time 0.024 seconds

Development of Automatic Crack Detection using the Gabor Filter for Concrete Structures of Railway Tracks (가버 필터를 사용한 철도 콘크리트 궤도 도상의 자동 균열 감지 개발)

  • Na, Yong-Hyoun;Park, Mi-Yun;Park, Ji-Soo;Park, Sung-Baek;Kwon, Se-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.458-465
    • /
    • 2018
  • Purpose: Concrete track that affects on railway safety can detect cracks using image processing technique. However, since a condition of concrete track and surface noisy are obstructed to detect cracks, there is a need for a way to remove them effectively. Method: In this study, we proposed an image processing to detect cracks effectively for Korean railway and verified its performance through experiment. We developed image acquisition system for capture a railway concrete track and acquired railway concrete track images, randomly selected 2000 images and detected cracks in the image process using proposed Gabor Filter Bank methods. Results: As a result, 94% of detection rate are matched to the actual cracks in same quality and format railway concrete track image. Conclution: The crack detection method using Garbor Filter Bank was confirmed to be effective for crack image including noise in the Korean railway concrete track. This system is expected to become an automated maintenance system in the existing human-centered railway industry.

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

The Valuation of HSA Business Using Broadband over Power Line (전력선통신망을 이용한 HSA사업의 경제적 타당성 분석)

  • Lyoo, Tae-Ho;Kim, Chang-Seob
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.202-214
    • /
    • 2007
  • The concept of HSA (Home Service Aggregator) is derived from performing the energy IT business efficiently as well as successfully launcing a new service based on BPL (Broadband over Power Line). The HSA business using a BPL can extend the field of energy industry and an give a chance to create a new demand by consumer-oriented services. This study focuses on the exact evaluation of HSA business using BPL, and reasonable trusty evaluation should be the first step to launch the HSA business. In this study, the categories of cost are comprised of equipment (mainly RSM and MGW) cost, instalation cost, and maintenance cost. AMR (Automatic Meter Reading), internet integration billing service, integration charging service, internet service, sorority service, and electricity safety are listed for benefit. In this study, the ROI of HSA business is 0.9594, which is less than 1. However, that value does not consider the electricity safety benefit which is classified as a social benefit. Therefore, the value can be above 1 if it includes social and private benefits.

Application of resistivity monitoring with tunnel excavation area (터널 굴착에 따른 전기비저항 모니터링 기술 적용)

  • Ahn, Hee-Yoon;Jeong, Jae-Hyeung;Cho, In-Ky;Kim, Jung-Ho;Rae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.405-420
    • /
    • 2008
  • Resistivity survey is one of the widely used methods for the investigation of stability of the ground or bedrock around tunnel and is also used as an essential base data for stability and reduction of construction cost through first-hand approximation of rock quality at design step. Generally, the analysis of resistivity survey data is performed by single measurement. When distribution variation of groundwater around a tunnel over time is necessary for maintenance of a tunnel, resistivity monitoring is very useful survey method to grasp distribution variation of groundwater. So we performed the grid line resistivity survey to monitoring resistivity variation for six times. And we also tried to evaluate application possibility of the resistivity monitoring for construction safety through providing detailed information on fault zones.

  • PDF

Operation and Command of Virtual Router Redundancy Protocol in Open N2OS (Open N2OS를 활용한 가상 라우터 이중화 프로토콜의 기능 동작과 명령어)

  • Lee, ChangSik;Ryu, HoYong;Park, Jaehyung
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.693-700
    • /
    • 2018
  • Virtual router redundancy protocol (VRRP) was designed as a solution to support fast fail-over in case of network failure. There exists virtual router which acts as default gateway in LAN, and the virtual router is dynamically elected between master and backup router. Through this protocol, end-hosts can be provided seamless network service. However, it needs expensive license fees and maintenance costs to adopt current commercial network operating systems. Furthermore, they are commonly enterprise proprietary software and inherently closed source. In order to tackle these problem, Open N2OS which is open source based open network software platform was developed. It has no dependency on hardware equipment, and provides high availability, scalability, various networking functions. In this paper, we handle VRRP operation and mechanism with related command line interface (CLI).

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.

Analysis of Turbulence on a Merge Influence Section in Uninterrupted Facility (연속류도로 합류영향구간 교통류 난류현상 분석)

  • Kim, Hyun-Sang;Do, Tcheol-Woong
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.217-228
    • /
    • 2009
  • Sections under the influence of merging in an uninterrupted facility create irregular interaction between vehicles, such as lane change, speed acceleration and deceleration because of the merging of ramp traffic flows which have traffic characteristics different from those of the main line. This causes a confused traffic flow phenomenon(turbulence), which is considered an unstable traffic characteristic between various continuous points in consideration of v conditions. In this study, in merge influence sections, detectors by lane-point were installed to create time and space-series -traffic data. The least significant difference(LSD), as the criteria for discriminating a significant speed change between points, was calculated to examine the turbulence. As a result, turbulence in merge influence section was found to change the zones of such occurrence and the seriousness levels according to traffic condition. Thus, the maximum merge influence section due to the turbulence was created in the traffic condition before congestion when traffic increases. According to characteristics of changes in speed, merge influence section was divided into upstream 100m$\sim$downstream 100m(a section of speed reduction), and downstream 100m$\sim$downstream 400m(a section of reduced speed maintenance and acceleration).

  • PDF

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.

System Design and Application of External Feature Extraction for Quality Maintenance of Yukwa (유과의 품질규격 유지를 위한 외형 정보 측정 시스템 설계 및 적용 연구)

  • Cho, Sung Ho;Kim, Tae Jung;Hwang, Heon
    • The Korean Journal of Community Living Science
    • /
    • v.24 no.2
    • /
    • pp.251-258
    • /
    • 2013
  • Korean oil and honey Yukwa has been paid attention as formal cake for traditional national seasons' holiday and religious service. Quality of Yukwa, however, has been maintained arbitrarily by each Yukwa manufacturer. Since even same Yukwa had severe differences in size, weight, and pattern, it has given the negative effect to the consumer. Yukwa industries need to setup the quantitative quality specifications instead of qualitative ones to maintain the uniformity of Yukwa quality. Efficient and economical inspection and process control system should be developed. In developing quality standards of Yukwa, features which can measure quality quantitatively in real time should be properly chosen. Existing quality features such as acidity, oxidization, hardness, viscosity, and texture were measured by the chemical or physical base destructive methods. Many research and developments have been performed in investigating and analyzing chemical transition states of those quality features as environment or storage condition changes. Most methods, however, require either off-line or complex treatment or time consuming process of analysis in evaluating quality features. Consumer, however, selects products mostly based on the external features such as shape, size, and color. Therefore, critical visual quality features should be chosen and the efficient real time measurement system must be developed. In this paper, computer image acquisition and processing system were developed and software modules were developed to extract the quantitative data of those features in real-time. Computer image processing system will promote in maintaining uniform quality of Yukwa and establishing quality standards of Yukwa.

Performance Characteristics of Flooded Type Evaporator for Seawater Cooling System with Heat Source Temperature of Mid-year (중간기 열원수 온도에 따른 만액식 해수냉각시스템의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Lee, Jeong-Mok;Kang, In-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The purpose of this study is to investigate the performance characteristics of seawater cooling system for a fishing vessel. The circulation amount of refrigerant, condensation capacity, evaporation capacity, compression work and coefficient of performance(COP) were analyzed as the heat source temperature changed. The experimental setup consisted of an open-type compressor, a shell&tube type condenser, an evaporator and an expansion valve. The heat source was controlled by a constant temperature chamber. The main results of this study are summarized as follows. The condensation capacity increased with increasing heat source temperature, and it was confirmed that the effect of circulating amount of refrigerant was dominant. The amount of heat for vaporization was almost constant even though the temperature of the heat source increased. On the other hand, the compression power was increased. This is because the compression ratio increases as the condensation pressure, the enthalpy difference between inlet and outlet, the amount of circulating refrigerant increases. The performance coefficient of this system showed a tendency decreasing with increasing heat source temperature. Therefore, the basic data of the seawater cooling system for the maintenance of the catch line of the shore fishing boats was acquired through this study, and it is considered that it will be sufficient for the actual design.