• Title/Summary/Keyword: On Line Maintenance

Search Result 633, Processing Time 0.027 seconds

A study on monitor filter PLC monitor device PON system (PON 시스템 감시 모니터용 PLC 소자)

  • Choi, Young-Bok;Park, Soo-Jin;Koh, Seok-Bong;Lee, Bong-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.22-26
    • /
    • 2007
  • In the fibre to the home (FTTH) era, it is expected that broadband network provisioning will require thousands of optical fibres to be accommodated in a central office for optical access networks. An optical fibre line testing system could be used to reduce maintenance costs and improve service availability depending on the PON's element manager capabilities and the maintenance procedures adopted by the network supplier. When monitoring optical fibres transmitting communication lights, a wavelength of 1625 nm is used for maintenance testing. The splitter installed optical filters allow the communication light to pass but that cut off the test light in the front of optical line terminals (OLTs) and optical network terminals (ONTs). In the economic point of view, We design new planer lightwave circuit splitter embedded filtter and study it optical property.

  • PDF

Case Study on Integrated In-line Oil Monitoring Sensor for Machine Condition Monitoring of Steel Making Industry (통합형 인-라인 오일 모니터링 센서의 제철설비 현장 적용사례)

  • Kong, H.;Han, H.G.;Kwak, J.S.;Chang, W.S.;Im, G.G.
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.73-77
    • /
    • 2010
  • One of the important trends for condition monitoring in the 21st century is the development of smart sensors that will permit the cost-effective continuous monitoring of key machine equipments. In this study, an integrated in-line oil monitoring sensor assigned for continuous in situ monitoring multiple parameters of oil performance is presented. The sensor estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical density of oil in three optical wave-bands ('Red', 'Green' and 'Blue') and water content is evaluated as relative saturation of oil by water. In order to evaluate the sensor's effectiveness, the sensor was applied to several used oil samples in steel making industry and the results were compared with those measured by standard test methods.

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

P2HYMN: Hybrid Network Systems for Maintenance Support in Power Plants (P2HYMN: 발전소 정비지원 하이브리드 네트워크 시스템)

  • Jin, Young-Hoon;Choo, Young-Yeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.7
    • /
    • pp.782-787
    • /
    • 2014
  • Due to the complicated steel structure and safety concern, it is very difficult to deploy wireless networks in power plants. This paper presents a hybrid network, named as $P^2HYMN$ (Power Plant HYbrid Maintenance Network), encompassing PLC (Power Line Communication), TLC (Telephone Line Communication), and Wireless LAN. The design goal of $P^2HYMN$ is to integrate multimedia data such as design drawings of control equipment, process data, and video image data for maintenance operation in electric power plants. A Multiplex Line Communication (MLC) device was designed and implemented to integrate PLC, TLC, and Wireless LAN into $P^2HYMN$. Performance test of $P^2HYMN$ has been conducted on a testbed under various conditions. The throughput of TLC was shown as 39 Mbps. Because the bandwidth requirement per camera is 8.5 Mbps on average, TLC is expected to support more thant four video camera at the same time.

A study on estimation of the total loss and damage ratio of maintenance monitoring sensor of subway tunnel (지하철 터널 유지관리 계측센서의 총 손망실율 산정 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • In this study, the total loss and damage ratio of maintenance monitoring which is installed and operated in the domestic and foreign tunnel structure is researched and analyzed for estimating the loss and damage ratio of maintenance monitoring sensor of subway tunnel. The total loss and damage ratio at the elapsed time of 5-6 years after installation is 14.2% in the Seoul metro line no.5,6 and 7, 14.8% in the section 1 of the Seoul metro line no.9, 13.9% in the Channel tunnel of England and all of them are close to 15%. Therefore, it is reasonable to reflect that the total loss and damage ratio of maintenance monitoring sensor of subway tunnel is estimated provisionally 15% on design, and hence the study of the loss and damage ratio with the number of elapsed years in long-term by the measurement category will be needed.

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

A Study on Line Classification for Efficient Maintenance of Railway Infrastructure (철도시설물 유지보수 효율화를 위한 선로등급 산정에 관한 연구)

  • Kim, In Kyum;Lee, Jun S.;Choi, Il-Yoon;Lee, Jeeha
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.672-684
    • /
    • 2016
  • UIC Codes 714R & 715R recommend the use of line classifications and their usage in maintenance work by employing notional traffic loads. However, the classification has not been applied to local lines and, therefore, a new line classification system based on UIC 714R has been proposed in this study. For this, various classification models of UIC, Germany, and UK have been studied first and equivalent traffic loads based on Korail's report, as well as on train timetables, have been derived. The results of the classifications have been compared with those of major European countries and it has been shown that the proposed classification is equivalent to the average value in the European cases. The line classification can be fully utilized during the decision making process of maintenance work and will also be used to model the Reliability Centered Maintenance (RCM) in the future.

Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line (배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.

A Prediction of the Electric Power in North Section of Kyongui-Line (경의선 북한구간 소요전력 예측)

  • 유원희;구동회;서정원
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.29-34
    • /
    • 2002
  • In relation to the connection of South-North railway(Kyongui-Line), the operating speed of the train in Kyongui-Line was reviewed. Due to the insufficient maintenance to support on the track of north section of Kyongui-Line, it is very old. The plan that the train run in the north section faster than present time was studied. Finally, the electric power required in the north section was predicted.

  • PDF