• Title/Summary/Keyword: On/off 제어

Search Result 1,210, Processing Time 0.027 seconds

A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers (두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

An Implementation of the RGB Remote Controller for LED Emotion Lighting of AtoN Facilities (항로표지 시설의 LED 감성조명을 위한 RGB 원격 콘트롤러의 구현)

  • Jeong, Yeong-Cheol;Choi, Jo-Cheon;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.475-480
    • /
    • 2012
  • This study on the methode is easied to distinguish with emotional visual lighting on AtoN facility using 3colors LED, and which is controlled to on-off switching of approach light in shore or harbor. The identification have easied to provide a differentiation between the AtoN facility of red and white light and surrounding light in harbor both sides. And the integrated controller have designed to left-right and serial sequential lighting system for harbor guidance using the GPS synchronous or timer. There is expectation effect that is prevent a confusion about distinguish of facility by ship's operator and to beautify a night scene of harbor, which is expressed to emotional identification lighting and variable color lighting on AtoN body by vertical layer color lighting using LED. In addition, the performance of AtoN is implemented to display with guidance light the harbor safety message by morse code lighting. Effectiveness of system is enhanced that age and power consumption reduce by candle alternated high light LED.

A Study on Smart Home Power-Control System with Power-Saving Green Adapter (전력절감 그린어뎁터를 이용한 스마트홈 전력 통제시스템)

  • Yoo, Seung-Jae;Park, Hee-Dong;Kim, Song-Gang
    • Convergence Security Journal
    • /
    • v.13 no.4
    • /
    • pp.85-92
    • /
    • 2013
  • Today we have an obligation to pass the beautiful earth and enrich people's lives to next generations. According to the keynote, governments have a lot of resources to support the smart grid policies. Also the demand of the implementation of smart home applied the concept of smart grid is increasing rapidly. But the construction of smart home is centered on a new public housing except the pre-existing house which is counted for most of more than 90% of total. In this study, we suggest the implementation solution to make smart-homelike for the pre-existing houses without additional wiring or construction. We develop the technology reducing the unnecessary standby power 800mW to 20mW drastically. If we apply this technology, by the power off of main IC the actual power depends on the consumption of minimal devise located on the AC input side. Then the standby power becomes approximately 20mW(110ac).

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

Design and Implementation of Education Globe System Based on Multimedia (멀티미디어 기반 교육용 지구의 시스템의 설계 및 구현)

  • Cho Soo-Hyun;Kim Young-Hak;Lee Jae-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.127-135
    • /
    • 2006
  • In the existing education using the globe. teaching contents are very simple and the relationship among learning units lacks a little bit because teaching materials are composed individually with the globe. Therefore, in this study, we developed the education glove system based on multimedia that is closely connected with teaching materials and the globe. This system is composed of the globe device and the learning software based on computer control. The globe device rotates itself on its axis as the solar center, and provides more efficient and visual education environment to students through the link between computer and the globe. The learning software provides the multimedia contents such as parallax, climate, culture, and education information about each country, and this software also can simulate the revolution of the earth around the sun. The globe device can be operated in off-line without the computer link. This system was developed by the industry cooperation and was displayed in the principal exhibitions. We have obtained positive results through the exhibitions and will promote the product in the future.

  • PDF

Field Experiment on Influence of Stack Effect to Pressure Differential System for Smoke Control (연돌효과가 급기가압 제연시스템에 미치는 영향에 대한 현장실험)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.194-200
    • /
    • 2008
  • In order to design and operate successfully the pressure differential system for smoke control which uses difference of pressure between compartments of building, architectural factors affecting the pressure field of building should be examined and the stack effect is one of the important factors. The field experiments on pressure field in two buildings of 21 stories and 31 stories in summer and winter season with regard to on/off condition of the pressure differential system are carried out to evaluate the influence of stack effect to evacuation and smoke management of high-rise building. In winter season when the stack effect increases, as the pressure differential system starts to operate, the pressure in upper stair rises largely due to the combination effect of the air infiltration from lobby to stair and the stack effect.

Development of Power Quality Measurement System for Harmonics Diagnosis of Electrical Equipment (전기설비의 고조파 진단을 위한 전력품질 측정시스템의 개발)

  • 유재근;이상익;전정채
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • Because of falling-off in power quality by harmonics, obstacles like lowering of capability, noise, vibration of power facilities and so on are occurred. Also generation of harmonics is inevitable and the point at harmonics is seriously gathering strength because energy saving installation using semiconductor circuit as countermeasures to enhance energy efficiency will be broadly spread and the use of energy conversion equipment like motor speed control contrivance, energy keeping installation and so on will increase, in the future. In order to eliminate harmonics obstacle, precision measurement and analysis on voltage, current, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion, and so forth are needed. In this paper, we developed low-cost measurement system to measure and analyze power quality connected with harmonics and verified it's performance by measuring and analyzing power quality in the three-phase and four-wire system.

An Efficient Algorithm to Minimize Total Error of the Imprecise Real Time Tasks with 0/1 Constraint (0/1 제약조건을 갖는 부정확한 실시간 태스크들의 총오류를 최소화시키는 효율적인 알고리즘)

  • Song, Gi-Hyeon
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.4
    • /
    • pp.309-320
    • /
    • 2006
  • The imprecise real-time system provides flexibility in scheduling time-critical tasks. Most scheduling problems of satisfying both 0/1 constraint and timing constraints, while the total error is minimized, are NP-complete when the optional tasks have arbitrary processing times. Liu suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on uniprocessors for minimizing the total error. Song et al suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on multiprocessors for minimizing the total error. But, these algorithms are all off-line algorithms. In the online scheduling, NORA algorithm can find a schedule with the minimum total error for the imprecise online task system. In the NORA algorithm, the EDF strategy is adopted in the optional scheduling.<중략> The algorithm, proposed in this paper, can be applied to some applications efficiently such as radar tracking, image processing, missile control and so on.

  • PDF

An experimental study on the fire hazard of Sheath Heater (시즈히터의 화재위험성에 관한 실험 연구)

  • Kim, Hakjoong
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.511-517
    • /
    • 2014
  • Recently, the fire by sheath heater has been occurred frequently on winter season. The sheath heater has simple internal structure and boils water simply. Therefore, the use of sheath heater has been increased. In this study, found the fire hazard property of sheath heater from understanding the fire mechanism through the experiment to get the measure for decreasing the occurrence of fire. For the analysis of the fire hazard property of the sheath heater, performed the test of temperature change and ignition temperature by using current product. On the result of test, the sheath heaters are the most dangerous appliance to arise fire. Water temperature controller attached to sheath heater is not sufficient to prevent overheating it. The sheath heater should have level switch of water and temperature controller for heater itself to shut off the power supply. Because the cause of fire by sheath heater is overheating itself in the situation of lack water.

A SRM driving with voltage and switching angle for maximum torque/efficiency and minimum torque ripple (최대 토크/효율 및 최소 토크맥동을 위한 스위칭각/전압에 의한 SRM 운전)

  • 차현록;김현덕;김광현;임영철;장도현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2000
  • This paper presents the switching angle and voltage to maximize torque/efficiency and minimize torque ripple in the 4-phase 6-poles Switched Reluctance Motor(SRM). SRM drive has high saturation and nonlinear characteristics of inductance. So we cannot hard to find optimal condition by using analytic method. Therefore it is hard to find the operating the switching angle and voltage through the approximated analysis and computer simulation by using SIMULINK according to the speed and torque required by load. From the results, we can say that the optimum average voltage is determined by the load only and the speed is determined by the optimum turn-on/off angle only. And the maximum efficiency and minimum torque ripple depend on switching angle, not on voltage. And then one-chip microcontroller controls the switching angle and voltage of an asymmetrical inverter in the SRM driver. This drive method, which is expect that the driving methods, which are maximizing torque/efficiency and minimizing torque ripple, will be suitable for the electric vehicle, the industrial application and household appliances.

  • PDF