• 제목/요약/키워드: Old medical

검색결과 5,486건 처리시간 0.032초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

퇴원환자의 가정간호 이용의사와 관련 요인 (A Study on the Expressed Desire at Discharge of Patients to Use Home Nursing and Affecting Factors of the Desire)

  • 이지현;이영은;이명화;손수경
    • 재활간호학회지
    • /
    • 제2권2호
    • /
    • pp.257-270
    • /
    • 1999
  • The purpose of this study is to investigate factors related to the intent of using home nursing of chronic disease patients who got out of a university hospital. For the purpose, the study selected 153 patients who were hospitalized and left K university hospital with diagnoses of cancer, hypertension, diabetes and cerebral vascular accident and ordered to be discharged and performed interviews with them and surveys on their medical records to obtain the following results. For this study a direct-interview survey and medical record review was conducted from June 28 to Aug. 30, 1998. The frequency and mean values were computed to find the characteristics of the study subjects, and $X^2$-test, t-test, factor analysis and multiple logistic regession analysis were applied for the analysis of the data. The following results were obtained. 1) When characteristics of the subjects were examined, men and women occupied for 58.8% and 41.2%, respectively. The subjects were 41.3 years old in aver age and had the monthly aver age earning of 0.99 million won or below, which was the most out of the total subjects at 34.6%. Among the total, 87.6% resided in cities and 12.4 in counties. The most left the hospital with diagnosis of cancer at 51.6%, followed by hyper tension at 24.2%, diabetes at 13.7% and cerebral vascular accident at 7.2%. 2) 93.5% of the selected patients had the intent of using home nursing and 6.5%, didn't. Among those patients having the intent, 85.6% had the intent of paying for home nursing and 14.4%, didn't. The subjects expected that the nursing would be paid 9,143 won in aver age and 47.7% of them preferred national authorities as the main servers. 86.3% of the subjects thought that home nursing business had the main advantage of making it possible to learn nursing methods at home and thereby contributing to improving the ability of patients and their facilities to solve health problems. 3) Relations between the intent of use and characteristics of the subjects such as demography-related social, home environment, disease and physical function characteristics did not show statistically significant differences among one another. Compared to those who had no intent of using home nursing, the group having the intent had more cases of male patients, the age of 39 or below, residence in cities, 5 family member s or more, no existence of home nursing servers, leaving the hospital from a non-hospitalized building, disease development for five months or below, hospitalization for ten days or more, non-hospitalization with in the recent one month, two times or over of hospitalization, leaving the hospital with no demand of special treatment, operation underwent, poor results of treatment, leaving the hospital with demand of rehabilitation services, physical disablement and high evaluation point of daily life. 4) Among those patients having the intent of using home nursing, 47.6% demanded technical nursing and 55.9%, supportive nursing. As technical nursing,' inject into a blood vessel ' and 'treat pustule and teach basic prevention methods occupied for 57.4%, respectively, topping the list. Among demands of supportive nursing, 'observe patients 'status and refer them to hospitals or community resources as available, if necessary' was the most with percent age point of 59.5. Regarding the intent of paying for home nursing, 39.2% of those patients wishing to use the nursing responded paying for technical services and 20.2, supportive services. In detail, 70.0% wanted to pay for a service stated as 'inject into a blood vessel', highest among the former services and 30.7%, a service referred to as 'teaching exercises needed to make the body of patients move', highest among the latter. When this was analyzed in terms of a relation between the need(the need for home nursing) and the demand(the intent of paying for home nursing), The rate of the need to the demand was found two or three times higher in technical nursing(0.82) than in supportive nursing(0.35). In aspects of tech ical nursing, muscle injection(1.26, the 1st rank) was highest in the rate while among aspects of supportive nursing, a service referred to as 'teach exercises needed for making patients move their bodies normally'(0.58, the 1st rank). 5) factors I(satisfaction with hospital services), II(recognition of disease state), III(economy) and IV(period of disease) occupied for 34.4, 13.8, 11.9 and 9.2 percents, respectively among factors related to the intent by the subjects of using home nursing, totaled 59.3%. In conclusion, most of chronic disease patients have the intent of using hospital-based home nursing and satisfaction with hospital services is a factor affecting the intent most. Thus a post-management system is needed to continue providing health management to those patients after they leave the hospital. Further, supportive services should be provided in order that those who are satisfied with hospital services return to their community and live their in dependent lives. Based on these results, the researcher would make the following recommendation. 1) Because home nursing becomes more and more needed due to a sharp increase in chronic disease patients and elderly people, related rules and regulations should be made and implemented. 2) Hospital nurses specializing in home nursing should be cultivated.

  • PDF

의료전달체계 실시 전후의 3차 진료기관 외래환자 이용양상 비교 (A Comparative Study on the Pattern of Outpatient Department Utilization at a Tertiary Level Hospital before and after Implementation of the Patient Referral System)

  • 이경수;김창윤;강복수
    • Journal of Preventive Medicine and Public Health
    • /
    • 제25권1호
    • /
    • pp.88-100
    • /
    • 1992
  • 1989년 7월 1일부터 실시된 의료전달체계가 3차진료기관에 미친 영향을 분석하기 위하여 실시전(1988년 7월 1일$\sim$1989년 6월 30일)과 실시후(1989년 7월 1일$\sim$1990년 6월 30일) 각 1년간 영남대학교 의과대학 부속병원의 내과, 일반외과, 소아과 외래를 이용한 공무원 및 사립학교교직원 의료보험 대상자 전원을 대상으로 실시한 성적을 요약하면 다음과 같다. 내과 환자는 의료전달체계 실시전 9,669건에 비해 실시후 6,181건으로 36.1% 감소했고, 일반외과는 1,864건에서 1,422건으로 23.7%, 소아과 환자는 3,372건에서 2,128건으로 36.9% 감소하였다. 내과 환자의 평균연령은 의료전달체계 실시전에 49.7세였으나 실시후 52.5세로 증가하였고, 일반외과도 46.5세에서 49.7세로 증가하였다. 성별 분포는 세 과 모두에서 큰 변화는 없었으나 일반외과의 경우 여자 환자가 약 3.0% 포인트 증가하였다. 지역별 분포에서 내과와 소아과 환자는 대구시내 이용자의 비율이 의료전달체계 실시후에 약간 증가하였고, 타 대진료권에서 방문한 환자 비율은 감소하였으나, 일반외과의 경우는 이와 상반된 결과를 보였다. 신환자의 비율은 내과의 경우 의료전달체계 실시전 24.4%에서 실시후 14.6%로 감소하였고, 일반외과는 36.0%에서 23.5%로, 소아과는 15.5%에서 8.3%로 현저히 감소하였다. 의료전달체계 실시 전후의 외래 방문 횟수는 내과가 각각 1.7회와 1.6회로 감소하였으나, 일반외과와 소아과는 큰 변화가 없었다. 의료전달체계 실시전후의 건당 외래진료 일수는 내과의 경우 각각 16.1일과 19.3일, 일반외과 12.0일과 15.2일, 그리고 소아과는 8.9일과 11.2일로 세 과 모두에서 실시후에 유의하게 증가하였다(P<0.01). 의료전달체계 실시 전후의 건당 검사건수는 내과가 각각 2.2건과 2.5건(P<0.01). 소아과가 0.8건과 1.1건(P<0.05)으로 유의하게 증가하였고, 일반외과의 검사건수도 약간 증가하였다. 건당 평균진료비를 불변가격으로 보았을 때, 일반외과가 실시전 75,900원에서 실시후 78,500원, 소아과는 실시전 12,700원에서 실신후 13,500원으로 증가하였으나, 내과는 43,900원에서 42,500원으로 실시후에 오히려 감소하였다. 질병분류를 17대 분류로 했을 때, 내과의 경우 내분비계질환, 순환기계 질환, 호흡기계 질환 등의 비율은 실시후에 증가하였으나, 소화기계 질환, 비뇨생식기 질환, 증상증후가 불명확한 질병은 감소하였다. 일반외과의 경우는 신생물 환자의 비율이 증가하였으나, 순환기계 질환과 증상증후가 불명확한 질병은 감소하였다. 소아과는 신생물, 신경감각계질환, 순환기계 질환 등의 비율은 증가하였으나, 호흡기계질환과 증상증후가 불명확한 질병은 감소하였다. 그리고 10대 다빈도 질환은 일반외과에서는 의료전달체계 실시후에 그 비중이 증가하였으나, 내과와 소아과는 변화가 없었다. 내과의 경우 위 십이지장염, 기타 간질환, 위기능 장애 등의 비율이 감소하였으나 본태성고혈압, 당뇨병, 폐결핵, 협심증 둥의 비율이 증가하였다. 일반외과의 경우에는 치핵, 항문열상, 종기 등의 비율이 감소하였고, 위암, 대장암, 담낭암 등의 비율은 증가하였다. 소아과의 경우 급성상기도염, 기관지염, 불명확한 장관감염 등의 비율은 감소하였고, 간질, 폐결핵, 천식, 임파성백혈병 등은 증가하였다. 이상의 결과로 보아 의료전달체계가 실시됨으로써 3차 진료기관의 외래 방문 환자의 건수, 건당 진료기간, 건당 방문횟수, 건당 검사건수, 건당 진료비, 질병의 구성 등에 변화를 준 것으로 생각된다. 향후 더욱 광범위한 자료를 이용하여 각 수준별 의료기관 간의 환자 흐름을 파악하고 세분화 된 질병분류를 이용하여 질병구조의 변화를 분석하는 연구가 필요할 것으로 생각된다.

  • PDF

내과적 문제로 수술이 불가능한 조기 비소세포성 폐암에서의 방사선치료 (Radiotherapy in Medically Inoperable Early Stage Non-small Cell Lung Cancer)

  • 김보경;박찬일
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.257-264
    • /
    • 2000
  • 목적 : 조기 비소세포성 폐암의 경우 수술이 최선의 치료법으로 생각 되고있다. 환자가 내과적인 질환으로 수술이 불가능한 경우, 혹은 수술을 거부한 경우 방사선치료가 수술의 대체적 치료로 사용 가능하다. 근치적방사선치료를 시행 받은 환자에서의 치료성적 및 이에 영향을 미치는 요인의 분석을 통하여 향후 치료에 도움을 얻고자 본 연구를 시행하였다. 대상 및 방법 : 서울대학교병원 치료방사선과에서 1987년 6월부터 1997년 6월 사이에 치료를 시행 받은 조직학적으로 진단된 조기 비소세포성 폐암 환자 32명을 대상으로 하였다. 수술이 불가능했던 이유로는 폐질환이 21명으로 가장 많았다. 대상환자의 중간 연령은 68세였으며, 조직학적으로는 편평상피암이 24명으로 가장 많았다. 임상 병기는 T1, T2, T3가 각각 5명, 25명, 2명이었으며, 진단시의 종양의 크기는 3$\~$5 cm가 13명으로 가장 많았다. 방사선치료는 6 MV또는 10 MV 선형가속기를 이용하여, 종양부위에 54.0$\~$68.8 Gy (중앙값; 61.2 Gy)를 조사하였고 12명의 환자에서는 동시분할조사를 시행하였다. 추적관찰기간은 2개월에서 93개월 (중앙값; 23개월)이었고, 생존기간은 치료개시일을 기준으로 산정하였다. 결과 : 전체생존률은 코년, 5년이 각각 44.6$\%$, 24.5$\%$이었으며, 무병생존률은 38.9$\%$, 28.3$\%$, 중앙생존기간은 23개월이었다. 전체환자 32명중 최종 추적관찰 시 25명이 사망하였으며, 이중 7명이 페암이외의 질환으로 사망하였다. 단변량분석 상 종양의 크기는 전체생존률과 무병생존률에 통계적으로 유의한 영향을 주는 요인으로 판정되었고 (p=0.0015, p=0.0022), T 병기는 전체생존률에 의미있는 요인으로 판정되었다(p=0.0395). 다변량분석 상 종양의 크기는 무병생존률에 통계적으로 의미있는 요인으로 판정되었으며(p=0.0317), 전체생존률에 영향을 주는 경향을 보였다 (p=0.0649). 종격동의 방사선조사 여부는 생존률에 영향을 주지 않았다. 결론 : 근치적방사선치료는 조기 비소세포성 폐암 환자로 내과적인 질환으로 수술 불가능한 경우나 환자가 수술을 거부한 경우, 특히 T1 또는 3 cm 이하의 종양에서는 수술적치료를 대치할 수 있는 치료법이다. 그러나 종양의 크기가 5 cm를 넘는 경우에는 방사선치료만으로는 장기생존자가 거의 없었으며, 따라서 이러한 환자의 치료에 있어 과분할조사나 기관지내 추가조사, 방사선감작제의 사용, 입체조형방사선치료, 강도변조방사선치료 등의 이용을 고려해야 할 것이다.

  • PDF

18인(人)의 비증(痺證) 논술(論述)에 대(對)한 연구(硏究) - 《비증전집(痺證專輯)》 에 대(對)한 연구(硏究) II - (Study of BiJeung by 18 doctors - Study of II -)

  • 손동우;오민석
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.595-646
    • /
    • 2000
  • I. Introduction Bi(痺) means blocking. BiJeung is one kind of symptoms making muscles, bones and jonts feel pain, numbness or edema. For example it can be gout or SLE etc. says that Bi is combination of PungHanSeup. And many doctors said that BiJeung is caused by food, fatigue, sex, stress and change of weather. Therefore we must treat BiJeung by character of patients and characteristic of the disease. Many famous doctors studied medical science by their fathers or teachers. So the history of medical science is long. So I studied ${\ll}Bijeungjujip{\gg}$. II. Final Decision 1. JoGeumTak(趙金鐸) devided BiJeung into Pung, Han, Seup and EumHeo, HeulHeo, YangHeo, GanSinHeo by charcter or reaction of pain. And he use DaeJinGyoTang, GyegiGakYakJiMoTang, SamyoSan, etc. 2. JangPaeGyeu(張沛圭) focused on division of HanYeol(寒熱; coldness and heat) in spite of complexity of BiJeung. He also used insects for treatment. They are very useful for treatment of BiJeung because they can remove EoHyeol(瘀血). 3. SeolMaeng(薛盟) said that the actual cause of BiJeung is Seup. So he thought that BiJeung can be divided into PungSeup, SeupYeol, HanSeup. And he established 6 rules to treat BiJeung and he studied herbs. 4. JangGi(張琪) introduced 10 prescriptions and 10 rules to cure BiJeung. The 1st prescription is for OyeSa, 2nd for internal Yeol, 3rd for old BiJeung, 4th for Soothing muscles, 5th for HanSeup, 6th for regular BiJeung, 7th for functional disorder, 8th for YeolBi, 9th for joint pain and 10th for pain of lower limb. 5. GangSeYoung(江世英) used PungYeongTang(風靈湯) for the treatment of PungBi, OGyeHeukHoTang(烏桂黑虎湯) for HanBi, BangGiMokGwaTang(防己木瓜湯) for SeupBi, YeolBiTang(熱痺湯) for YeolBi, WoDaeRyeokTang(牛大力湯) for GiHei, HyeolPungGeunTang(血楓根湯) for HyeolHeo, ToJiRyongTang(土地龍湯) for the acute stage of SeupBi, OJoRyongTang(五爪龍湯) for the chronic stage of SeupBi, and so on. 6. ShiGeumMook(施今墨) devided BiJeung into four types. They are PungSeupYeol, PungHanSeup, GiHyeolSil(氣血實) and GiHyeolHeo(氣血虛). And he introduced the eight rules of the treatment(SanPun(散風), ChukHan(逐寒), GeoSeuP(, CheongYeol(淸熱), TongRak(通絡), HwalHyeol(活血), HaengGi(行氣), BoHeo(補虛)). 7. WangYiYou(王李儒) explained the acute athritis and said that it can be applicable to HaneBi(行痺). And he used GyeJiJakYakJiMoTang(桂枝芍蘂知母湯) for HanBi and YeolBiJinTongTang(熱痺鎭痛湯) for YeolBi. 8. JangJinYeo(章眞如) said that YeolBi is more common than HanBi. The sympthoms of YeolBi are severe pain, fever, dried tongue, insomnia, etc. And he devided YeolBi into SilYeol and HeoYeol. In case of SilYeol, he used GyeoJiTangHapBaekHoTang(桂枝湯合白虎湯) and in case of HeoYeol he used JaEumYangAekTang(滋陰養液湯). 9. SaHaeJu(謝海洲) introduced three important rules of treatment and four appropriate rules of treatment of BiJeung. 10. YouDoJu(劉渡舟) said that YeolBi is more common than HanBi. He used GaGamMokBanGiTang(加減木防已湯) for YeolBi, GyeJiJakYakJiMoTang or GyeJiBuJaTang(桂枝附子湯) for HanBi and WooHwangHwan(牛黃丸) for the joint pain. 11. GangYiSon(江爾遜) focused on the internal cause. The most important internal cause is JeongGiHeo(正氣虛). So he tried to treat BiJeung by means of balance of Gi and Hyeol. So he ususlly used ODuTang(烏頭湯) and SamHwangTang(三黃湯) for YeolBi, OJeokSan(五積散) for HanBi, SamBiTang(三痺湯) for the chronic BiJeung. 12. HoGeonHwa(胡建華) said that to distinguish YeolBi from Hanbi is very difficult. So he used GyeJiJakYakJiMoTang in case of mixture of HanBi and YeoBi. 13. PiBokGo(畢福高) said that the most common BiJeung is HanBi. He usually used acupuncture with medicine. He followed the theory of EumYongHwa(嚴用和)-he focused on SeonBoHuSa(先補後瀉). 14. ChoiMunBin(崔文彬) used GeoPungHwalHyeolTang(祛風活血湯) for HanBi, SanHanTongRakTang(散寒通絡湯) for TongBi(痛痺), LiSeupHwaRakTang(利濕和絡湯) for ChakBi(着痺), CheongYeolTongGyeolChukBiTang(淸熱通經逐痺湯) for YeolBi(熱痺) and GeoPungHwalHyeolTang(祛風活血湯) for PiBi(皮痺). 15. YouleokSeon(劉赤選) introduced the common principle for the treatment of BiJeung. He used HaePuneDeungTang(海風藤湯) for HaengBi(行痺), SinChakTang(腎着湯), DokHwalGiSaengTang(獨活寄生湯) for TongBi(痛痺), TongPungBang(痛風方) for ChakBi(着痺) and SangGiYiMiTangGaYeongYangGakTang(桑枝苡米湯加羚羊角骨) for YeolBi(熱痺). 16. LimHakHwa(林鶴和) said about TanTan(movement disorders or numbness) and devided TanTan into the acute stage and the chronic stage. He used acupuncture at the meridian spot like YeolGyeol(列缺), HapGok(合谷), etc. And he also used MaHwangBuJaSeSinTang(麻黃附子細辛湯) in case of the acute stage. In the chronic stage he used BangPungTang(防風湯). 17. JinBaekGeun(陳伯勤) liked to use three rules(HwaHyeol(活血), ChiDam(治痰), BoSin(補腎)) to treat BiJeung. He used JinTongSan(鎭痛散) for the purpose of HwalHyeol(活血), SoHwalRakDan(小活絡丹) for ChiDam(治痰) and DokHwalGiSaengTang(獨活寄生湯) for BoSin(補腎). 18. YimGyeHak(任繼學) focused on YangHyeolJoGi(養血調氣) if the stage of BiJeung is chronic. And in the chronic stage he insisted on not using GalHwal(羌活), DokHwal(獨活) and BangPung(防風).

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

한국의 세계기록유산 보존 현황 및 과제 (Preservation of World Records Heritage in Korea and Further Registry)

  • 김성수
    • 한국기록관리학회지
    • /
    • 제5권2호
    • /
    • pp.27-48
    • /
    • 2005
  • 이 논문은 한국의 세계기록유산에 대하여 먼저 그 의미와 가치를 재확인하고, 이들 세계기록유산에 대한 보존 관리 및 그 현황을 조사하며, 한국의 기록유산을 디지털화 하는데 있어서의 문제점과 해결책을 모색하고, 추후 한국의 기록유산 중 세계기록유산으로 등록되기를 희망하는 4종의 기록물들에 대한 가치와 의의를 고찰한 연구이다. 본 연구의 상세 사항은 다음과 같다. 첫째, 제2장에서는 한국의 세계기록유산에 대한 가치와 의의를 고찰하였다. 먼저 세계기록유산의 선정기준과 절차 등을 먼저 파악하고, 한국의 세계기록유산인 "훈민정음" "조선왕조실록" "승정원일기" "직지(백운화상초록불조직지심체요절(白雲和尙抄錄佛祖直指心體要節))"에 대하여 각각 그 가치와 의미를 분석하였다. 둘째, 제3장에서는 '한국의 세계기록유산 보존 관리 현황'에서는 세계기록유산을 보존하고 있는 <서울대학교 규장각> <국가기록원 부산기록정보센터> <간송미술관>의 기관별로 그 보존 관리 현황을 고찰하였다. 그 결과, 이 3기관 모두 세계기록유산 보존 관리 현황은 '매우 우수하다'고 평가할 수 있었다. 즉, 1)그 세부적인 보안대책이 완벽하다. 2)그 보존방법에 있어서도 항온 항습의 특별한 서고를 별도로 마련하고, 이 서고 내에서 다시 '오동나무 상자 서장(書欌)'을 설치한 후, 이들 상자와 서장 속에 세계기록유산을 납입하여 보존하고 있다. 3)방화장치와 서고조명 및 소독 등에도 철저를 기하고 있음 등을 파악하였다. 셋째, 제4장에서는 '한국의 기록유산 디지털화 과제'에 대하여 개괄적으로 고찰하였다. 그 결과, 한국 기록유산의 디지털작업 및 DB구축에서 '디지털화 표준'이 가장 중요한 문제이며, 이 문제의 해결을 위해서는 디지털화(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 시급함을 지적하였다. 그리고 국가기록관리시스템을 개발한 경험이 있는 <국가기록원>과 한국학 고기록물의 디지털화에 많은 관심을 가진 <문화재청>이 공동으로 노력하여, 한국학 관련 기록유산의 디지타이제이션(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 요구됨을 파악하였다. 넷째, 제5장 '세계기록유산 등록을 추후 희망하는 한국의 기록유산'에서는 한민족의 기록유산 중에서 차후 세계기록유산으로 등재되기를 희망하는 4종 즉, 1)<해인사 고려대장경 경판>, 2)"동의보감", 3)"삼국유사", 4)"무구정광대다라니경"의 기록물에 국한하여, 그 어떤 의미에서 세계적인 가치와 의의가 있는가를 고찰하였다.

선천성 근육성 사경의 임상적 특징과 경과 (Clinical characteristics and courses of congenital muscular torticollis)

  • 최경은;이희철;윤소영;천정미;신손문;한병희;이용택
    • Clinical and Experimental Pediatrics
    • /
    • 제52권11호
    • /
    • pp.1273-1278
    • /
    • 2009
  • 목 적:선천성 근육성 사경은 흉쇄유돌근의 단축으로 경부가 기울어지고 이로 인해 안면의 비대칭적인 발달을 야기하며 목에 종괴가 만져지는 경우가 흔하다. 대부분 생후 수개월 이내에 소실되나 수술이 필요할 수도 있어 빠르고 정확한 진단이 요구된다. 선천성 근육성 사경 발생에 관여하는 산과적 위험요인을 살펴보고 임상 양상 및 치료 경과를 살펴보고자 하였다. 방 법:2007년 2월부터 2008년 8월까지 관동대학교 소아청소년과 외래에 사경으로 내원한 6개월 이하 영아들 중 본원에서 출생한 98명을 대상으로 병력청취, 이학적 검사, 신경학적 검사와 경추 방사선 및 초음파 검사를 시행하였다. 종괴군과 자세군으로 분류하고 산전 병력과 출생력, 산과적 위험요인을 조사하였으며, 재활의학과와 협진을 통해 가정 및 외래에서 물리치료를 받았고, 보호자와 전화 통화 및 외래 면담을 실시하였다. 결 과:진찰 소견 상 36명(36.7%)은 흉쇄유돌근의 종괴나 긴장이 촉진되었으며, 62명(63.3%)은 종괴 없이 목이 한쪽으로 기울었다. 81명의 환아에서 경부 초음파를 시행하였고, 종괴군은 모두 초음파에서 근육성 사경을 확인하였고, 자세군 62명 중 48명이 초음파를 시행하여 1명에서 근육성 사경이 확인되었다. 종괴군의 사경 발견시기는 평균 1.4개월, 자세군은 2.7개월로, 종괴군이 자세군에 비해 어린 나이에 발견되었다(P<0.001). 종괴군은 두혈종과 산류가 자세군보다 흔했고, 자세군은 사두증이 종괴군보다 흔하게 관찰되었다. 안과 검진이나 경추 방사선 검사는 모두 정상이었다. 재활의학과에서 물리치료를 시행한 43명 중 평균 재활 치료 기간은 종괴군 4.6개월, 자세군 2.6개월로, 자세군이 종괴군보다 유의하게 치료 기간이 짧았다(P=0.005). 총 88명의 환아 중 87명이 완전히 회복하였고, 불완전 회복을 보인 1명은 외래 추적관찰 중이다. 결 론:선천성 근육성 사경은 대부분 예후가 좋으나 수술을 요할 수도 있기 때문에 조기에 정확한 진단 및 치료를 요한다. 6개월 이하의 선천성 근성 사경 환아를 대상으로 산과적 위험 요인을 살펴봄으로써 출생 손상 및 복잡 분만과의 관련성을 확인하였고 조기 진단 및 치료를 통해 대부분 호전되는 것을 확인할 수 있었다.

섬유농성 농흉의 비디오 흉강경을 이용한 치료 (Video-Assisted Thoracoscopic Surgery for Fibrinopurulent Empyema)

  • 손정환;모은경;지현근;김응중;신호승;신윤철
    • Journal of Chest Surgery
    • /
    • 제36권6호
    • /
    • pp.404-410
    • /
    • 2003
  • 농흉은 단계에 따라 각기 다른 치료방법이 적용되어 왔다. 삼출성 농흉단계(stage I, exudate stage)에서는 적절한 항생제와 흉관 삽입을 통한 배농이, 기질화된 농흉단계(stage III, organized stage)에서는 개흉술을 통한 흉막박피술이 우선적으로 고려되어 왔다. 하지만 섬유농성 농흉(stage II, fibrinopurulent stage)의 치료법은 아직 확립이 안 되어 각자의 경험에 의존하여 여러 방법으로 치료되어 왔고, 최근 흉강경수술(Video-Assisted Thoracoscopic Surgery, VATS)이 치료방법 중 하나로 시도되고 있다. 이에 비디오 흉강경을 이용하여 섬유농성 농흉(stage II, fibrinopurulent stage)을 치료한 5예를 분석하여 보고하고자 한다. 대상 및 방법: 2001년 6월부터 2002년 2월까지 강동성심병원 내과에서 폐렴과 이에 동반된 농흉으로 진단받고 치료받던 환자들 중 1차 치료인 항생제 및 경피적 배농술(Percutaneous Catherter Drainage, PCD) 또는 흉관삽입을 통한 배농과 섬유소 용해제 치료에 반응하지 않은 5명의 환자를 대상으로 비디오 흉강경을 이용하여 농흉 제거와 흉강세척술을 시행하였다. 모든 환자에서 수술 전 흉부 컴퓨터단층촬영을 통해 농흉의 국한된 위치와 크기, 폐 실질 내 기저질환의 유무를 확인하였다. 결과: 5명의 환자에서 모두 개흉술로의 전환 없이 비디오 흉강경을 이용하여 흉강내 농을 제거하고 흉관을 적절한 위치에 삽입하였다. 남녀비는 4 : 1이었고, 평균 연령은 53세(26~73세)였다. 평균 수술시간은 73.4분(52~95분), 수술 후 평균 흉관삽입 기간은 12.4일(6~19일), 수술 후 평균 재원일수는 20.8일(10~36일)이었으며, 모든 환자에서 수술 후 백혈구 수치의 감소, 통증 및 발열의 소실 등 임상증상의 호전과 함께 흉부 단순촬영 소견에서 폐의 충분한 확장소견이 보였다. 수술 후 재원기간 중 수술에 따른 특별한 합병증은 없었으며, 5예 모두 추적검사를 시행하였고 추적검사 기간은 평균 6.7개월(1~12개월)이었으며, 모든 환자가 재발 얼이 잘 지내고 있었다. 걸론 흉관삽 입과 항생제 치료에 반응 없는 섬유농성 농흉(stage II, fibrinopurulent stage)의 치료방법으로 비디오 흉강경을 이용한 조기수술로서 이 단계의 농흉을 적절히 치료할 수 있었고, 기질화된 농흉 단계로의 진행을 막을 수 있었다고 생각한다.

Bootstrap 기법을 이용한 개의 혈청검사 일부 항목의 참고범위 평가 (Evaluation of Reference Intervals of Some Selected Chemistry Parameters using Bootstrap Technique in Dogs)

  • 김으뜸;박선일
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.509-513
    • /
    • 2007
  • 혈청검사항목의 해석기준으로 사용하는 참고범위는 측정 장비와 병원마다 차이를 보이기 때문에 병원 간 정보를 교환하고 해석하는데 어려움이 많다. 또한 동일한 병원에서도 내원한 환자의 특성을 고려하여 참고범위를 재설정하는 것이 일반모집단의 특성을 제대로 반영한다. 본 연구에서는 강원대학교 수의학부대학 동물병원에서 설정한 혈청화학 검사 항목의 참고범위를 재평가하기 위하여 2005-2006년 동안 본원에 내원한 임상적으로 건강한 개 100두(1-8세, 체중 2.2-5.8 kg)의 혈청검사 일부 항목을 모수 및 비모수적 bootstrap 모의시험으로 분석하였다. 평가항목은 BUN(mg/dl), cholesterol(mg/dl), calcium(mg/dl), aspartate aminotransferase(AST, U/L), alanine aminotransferase(ALT, U/L), alkaline phosphatase(ALP, U/L) 및 total protein(g/dl)으로 Ektachem DT 60 분석기(Johnson & Johnson)로 측정하였다. 칼슘을 제외한 모든 항목이 왜곡이 매우 심한 분포를 보였으며 특히 혈청 효소항목의 outlier는 전체 자료의 5-9%, 기타 항목은 1-2%를 보였다. 각 항목의 분포에 상관없이 모수적 방법에 비하여 비모수적 방법으로 추정한 참고범위가 임상적으로 유용하였으며 추정된 참고범위는 BUN 14.7(7.0-24.2), cholesterol 227.3(120.7-480.8), calcium 10.9(8.1-12.5), AST 25.4(11.8-66.6), ALT 25.5(11.7-68.9), ALP 87.7(31.1-240.8), and total protein 6.8(5.6-8.2)로 나타났다. 이러한 결과는 모집단의 특성을 고려하여 참고범위를 재설정하는데 비모수적 모의시험이 매우 유용하며 특히 측정항목의 분포에 무관하게 사용할 수 있는 장점이 있는 것으로 사료된다.