A STUDY ABOUT ALVEOLAR CREST BONE HEIGHT BEFORE AND AFTER ORTHODONTIC TREATMENT BY USING BITEWING FILM (교익사진을 이용한 교정치료 전후의 치조골 높이 변화에 관한 연구)
-
- The korean journal of orthodontics
- /
- v.27 no.3 s.62
- /
- pp.421-430
- /
- 1997
Alveolar bone grows with development of tooth germs and roots; bone deposition occurs with tooth eruption. Bone components undergoes processes of resorption and deposition, and when the balance between them is disrupted, decrease in alveolar bone height or excessive bone deposition result. It has been hon that repositioning of teeth through orthodontic treatment can cause alveolar bone resorption which result in decreased alveolar bone height, and there have been many studies to evaluate such effects. X-ray films that could be replicated and standardized were chosen in clinical studies, and among them, bitewing films were used for objective evaluation of changes in alveolar bone level. Twenty subjects, 10 to 13-year- old (average 12.2) children with Cl I molar key, healthy oral condition, no congenital missing, no periodontal disease, and pre-and post-orthodontic bitewing films, were randomly selected for comparison of alveolar bone heights. Amounts of tooth and changes in alveolar bone heights were analyzed. The following results were obtained: 1. Amount of tooth movement in canine, premolar, and molar regions, changes in tooth axis, and changes in alveolar bone heights were measured, and the mean and median values were obtained. 2. When pre-and post-orthodontic alveolar bone levels were compared, larger changes were noticed in maxilla than mandible. 3. When mesio-distally compared, larger changes were observed in the distal sides of 3D3 and 4M3, mesial sides of 4M3 and 4D3, distal sides of 4D3 and 5M3, mesial sides of 5M3 and 5D3, md distal sides of 5D3 and 6M3. 4. When the amounts of tooth movements(TX, TY)and changes in tooth axis(A) were compared,34TX, 34TY, 34A of both sides in maxilla were greater, iud changes in alveolar bone level were greater than any other region.
The seventeen barnyardgrass [Echinochloa crus-galli (L.) Beauv.] accessions, which were collected national-widely in 1986 and selected two times through 1987, were experimented at 1988. To study the degree of ecological variations of the collected accessions of native barngardgrass species as a weed, the experiment was conducted with Wagner pots in size of 1/5000a and under P.E. film house. Among 57 characters, 100 grains weight, rate of tiller increase from transplanting to 30 days, the number of the maximum tillers and rate of dry weight increase from 15 DAS to 22 DAS were become intra-specific variarions as higher coefficient of varation than 30%, the size of the first leaf, fresh weight and dry 22 seedlings, rate of productive tiller, panicle number and tillering divergence made intra-specific variations as more and less C. V. than 25%, while the required days upto heading since seeding at June 6. rate of fresh/dry weight and plant height of 22 days old seedling made intra-specific variations as the coefficient of variation of about 50%. Among the attributes the color in leaf, leaf sheath, mid-ribs, node, spike, grain, and plant type, length of leaf marginal tooth, grain shape, purple bend on leaf were seemed useful to indentify the accessible specific.
This paper examines how the cinematic representation of the Japanese military "comfort women" stimulates 'imagination' in the realm of everyday life and in the memory of the masses, creating a common awareness and affect. The history of the Japanese military "comfort women" was hidden for a long time, and it was not until the 1990s that it entered the field of public recognition. Such a transition can be attributed to the external and internal chronopolitics that made possible the testimony of the victims and the discourse of the "comfort women" issue. It shows the peculiar status of the comfort women history as 'politics of time'. In the same vein, the cinematic representations of the Japanese military "comfort women" can be found in similar chronopolitics. The 'comfort women' films have shown the dual time frame of the continuity and discontinuity of the 'silence'. In Korean film history, the chronotope of the reproduction of "comfort women" can be divided into four phases: 1) the fictional representations of "comfort women" before the 1990s 2) documentaries in the late 1990s as the work of testimony and history writing, 3) melodramatic transformation in the feature films in the 2000s, and 4) the diffusion of media and categories. The purpose of this article is to focus on the first phase and the third phase in which the issue of 'comfort women' is represented in the category of popular fiction films. While the "comfort women" representations before 1990 were strictly adhering to the framework of commercial movies and pursued the sexual exploitation of "comfort women" history, the recent films since the 2000s are experimenting with various attempts in the style of popular imagination. Especially, the emergence of 'comfort women' feature films in the 2000s, such as Spirit's Homecoming, I Can Speak, and Herstory, raise various questions as to whether we are "properly" aware of issues and how to remember and present the "cultural memory" of comfort women. Also, focusing on the cinematic representation strategies of the 2000s "comfort women", this article discusses the popular politics of melodrama, the representation of victims and violence, and the feature of 'comfort women' as meta-memory. As a melodramatic imagination and meta-memory for the historical trauma, the "comfort women" drama shows the historical, political, and aesthetic gateways to which the "comfort women" problem must pass. As we have seen in recent fiction films, the issue of "comfort women" goes beyond transnational relations between Korea and Japan; it demands a postcolonial task to dismantle the old colonial structure and explores a transnational project in which women's movements and human rights movements are linked internationally.
The habit of finger sucking is a reflex occurring in the oral stage, due to nutritive and psychological desire. The habit of finger sucking is considered to be normal till 3 years of age. Dento-skeletal effect on maxillo-mandibular complex including occlusion is naturally correction, when habit stopped before 3 years. If finger sucking continues till
Alcoholics increased susceptibility to microbial infection that is associated with decreased immunity. but there has been little experimental evidence to support alcoholics-induced increase of microbial infection directly in non-specific immunity. Therefore, we were used the method of phagocytic-plaque including all the stimulating factors for the phagocytosis, subtypes of lymphocytes and T-lymphocyte proliferation. The experimental groups were divided into 3 groups: (1) alcoholics who were hospitalized less than 1 week (newly hospitalized alcoholics), (2) alcoholics who were hospitalized more than 2 weeks (old hospitalized alcoholics), (3) healthy blood donors. We have studied 98 alcoholics and 35 healthy blood donors and control groups. A physician has checked the biological markers and diagnosed the body-condition alcoholics. The immunity and non-specific immunity on the alcoholics were analyzed by using the simultest kit and flow cytometry. Proliferation of the lymphocytes was analyzed by the phytohemmagglutinine mitogen. Phagocytosis and migration properties of leukocytes were identified on the layer formed by Staphylococcus aureus Cowan I strain. Biological markers of alcoholics and control groups, by such as blood glucose,
This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.
The study aimed to determine effects of light emitting diode (LED) and the ultraviolet radiation (UVA) light of plant factory on plant growth and ascorbic acid content of spinach (Spinacia oleracea cv. Shusiro). Plants were grown in a NFT (Nutrient Film Technique) system for 28 days after transplanting with fluorescent light (FL, control), LEDs and UVA (Blue+UVA (BUV), Red and Blue (R:B(2:1)) + UVA (RBUV), Red+UVA (RUV), White LED (W), Red and Blue (R:B(2:1)), Blue (B), Red (R)) under the same light intensity (
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70