• 제목/요약/키워드: Oil-paper insulation

검색결과 149건 처리시간 0.022초

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.

유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성 (Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation)

  • 선종호;이상화;김광화
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.136-144
    • /
    • 2004
  • 본 논문에서는 유침절연에 대한 열열화와 전기적열화 실험을 실시하여 유중가스분석법을 이용한 유침절연의 고장원인 진단에 대한 신뢰성을 향상시키는 방안에 대하여 연구하였다. 유침절연의 고장원인에 대하여 주도가스법과 탄화수소가스의 구성률, CO/$CO_2$비와 같은 진단요소를 단독으로 사용하는 것보다는 진단요소들의 상호관계를 이용하는 것이 유침절연의 고장원인을 신뢰성 있게 진단하는 것으로 나타났다.

변압기 절연유의 열화에 따른 대전특성 (Characteristics of Static Electrification on Insulation Oil Aging)

  • 권동진;김한상;정용기;김경화;김두석;곽희로;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1615-1618
    • /
    • 1994
  • This paper studied the streaming electrification of the U.H.V. transformer with the spinning cylinder system, and compared and analyzed it with the conventional forced flowing system which uses a pump or gas for oil flowing. Also, accumulated surface voltage in its electrified material was measured with the electrostatic voltmeter, and the effect of insulation oil aging was measured. As results, in spinning cylinder system, characteristics of the streaming electrification to its rotational speed and oil temperature are same tendency as those of tile forced flowing system and it showed the spinning cylinder system is useful to study the streaming electrification. And, aging of insulation oil increases the electricity of streaming electrification at initial stage of aging.

  • PDF

식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성 (Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil)

  • 곽동순
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

유중 부분방전에 의한 방사전자파의 측정 (Measurement of Electromagnetic Wave Generated by Partial Discharges in an Insulation Oil)

  • 박대원;이정윤;조향은;김민수;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1453-1458
    • /
    • 2011
  • This paper dealt with the measurement and analysis of electromagnetic waves generated by partial discharges in insulation oil to develop insulation diagnostic techniques for power transformer. Two types of narrow-band monopole antennas with the resonant frequency of 500 MHz and 1 GHz were designed and fabricated. We simulated defects which consist of a needle electrode with curvature radius of 10 ${\mu}m$ and a plane electrode with diameter of 60 mm in insulation oil. From the experiment, the maximum output voltage of the fabricated antennas was measured; 620 $mV_{max}$ for 500 MHz resonant frequency and 920 $mV_{max}$ for 1 GHz resonant frequency.

  • PDF

Application of Dielectric Spectroscopy Measurements for Estimating Moisture Content in Power Transformers

  • Ekanayake, Chandima;Gubanski, Stanislaw M.;Fernando, M.A.R.M.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.81-89
    • /
    • 2004
  • Frequency Domain Spectroscopy (FDS) measurements were performed on pressboard samples containing different moisture contents and on insulation system of power transformers. The results were used for evaluating sensitivity of the so-called X - Y model, which is applied for estimating moisture content in transformer insulation using the results of FDS measurements. Based on the observations of this analysis a simplified model, called X model, was introduced in which the presence of spacers in transformer insulation has been neglected. Finally, reliability of the X model was assessed by comparing estimates of moisture contents based on FDS measurements on field installed power transformers with moisture contents obtained from chemical analyses of their oil samples.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

변압기 열열화 모의 고장어 대한 유중가스 분포연구 (A study on gas dissolved distribution in oil for simulated transformer thermal faults)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1800-1802
    • /
    • 2003
  • This paper describes a study on gas dissolved distribution in oil for simulated transformer thermal faults. Experimental chamber was setup for simulation of transformer thermal faults or discharge in oil with or without insulation paper. The experimental results showed that dissolved gases in oil excluding the paper did not evolved upto $150^{\circ}C$. Hereafter the planned gas dissolved analysis will be continuously carried out for transformer fault conditions with or without insulation paper related to water absorption, arc and partial discharge.

  • PDF

전극 형태와 전극 간 거리에 따른 전기적 특성 분석 (Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes)

  • 김태희;이순형;황미용;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

주상변압기의 절연매질인 광유의 절연파괴특성에서 분해생성물의 영향 (Effect of Decomposition Product on the Insulation Characteristics of Mineral Oil as Insulation Medium of Distribution Transformer)

  • 임동영;박숭규;박철호;김기채;이광식;최은혁
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper deals with the effect of decomposition products which occur in breakdown of mineral oil, on the insulation characteristics of its oil. Breakdown tests in the oil were conducted by the proposed experimental methods under a quasi-uniform field and AC HV (60Hz). The breakdown voltage in the oil shows characteristics of dispersion from successive breakdowns and, it is found that there are three patterns of the decomposition products behavior at the process of breakdown progress in the oil. Finally, the breakdown voltage dispersion in the oil can be described in detail based on the behavior patterns of the decomposition products and its diffusion time.