• Title/Summary/Keyword: Oil-filled transformer

Search Result 53, Processing Time 0.025 seconds

A Study on the UHF PD Sensor and Novel Pattern Analysis Technology for Diagnosis of the High Power Apparatus (초고압 전력기기 진단을 위한 UHF PD 센서 및 패턴분석 기술에 관한 연구)

  • 강원종;이창준;강윤식;이희철;박종화
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.83-90
    • /
    • 2004
  • This paper describes investigations of the UHF(Ultra High Frequency) PD(Partial Discharge) measuring technology designed for monitoring of PD in high power apparatus. Based on the spiral antenna theory, the hole type sensor for GIS with metal flange spacer and injection type sensor for oil filled transformer are developed. The experimental results show measurement characteristics of the PD sensor for several artificial defects in gas-insulated system(GIS) and oil transformer. Moreover, we proposed the new $\phi$-f-q method for the purpose of condition assessment of high power apparatus.

A Fault Diagnosis Method of Oil-Filled Power Transformers Using IEC Code based Neuro-Fuzzy Model (IEC 코드 기반의 뉴로-퍼지모델을 이용한 유입변압기 고장진단 기법)

  • Seo, Myeong-Seok;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using IEC code based neuro-fuzzy model. The proposed method proceeds two steps. First, IEC 60599 method is applied to diagnosis. If IEC code can't determine the fault type, neuro-fuzzy model is applied to effectively classify the fault type. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration (유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

Developement of Gas Detector Dissolved In Transfomer Oil (변압기 절연유중 수소 가스의 검지 시스템 설계)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.207-210
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases($CO,\;CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system

  • PDF

A Fault Diagnostic Expert System for Silicone Oil-filled Transformer Using Dissolved Gas Analysis (유중가스분석법을 이용한 실리콘 유입변압기 고장진단 전문가 시스템)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Jun, Young-Jae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.374-376
    • /
    • 2001
  • In this paper, we developed the fault diagnostic expert system of silicone-immersed transformer using dissolved gas analysis. The knowledge base module consists of the knowledge using the rule: if Then . The inference engine uses the fuzzy rule for the management of uncertainty of the boundary and rule and derivate the Belief and Plausibility of the normality and fault using Dempster-Shafer theory. The expert system is connected to the database and it can manages the history of gas-data of the transformer.

  • PDF

Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer (식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

Developement of Gas Detector Dissolved In Transfomer Oil (변압기 절연유중 수소 가스의 검지 시스템 설계)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1842-1844
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases(CO, $CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system.

  • PDF

Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers (배전용 변압기의 진단을 위한 위상 검출 장치의 개발)

  • Kim, Young-Chun;Choi, Do-Hyuk;Yoon, Yong-Han;Min, Kyeoung-Rae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.