• 제목/요약/키워드: Oil removal system

검색결과 79건 처리시간 0.029초

Development of an Integrated Oil Purification System (통합형 오일 정제 시스템의 개발)

  • Hong, Sung-Ho;Lee, Kyung-Hee;Jeong, Nam-Wha
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System (Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제25권6호
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

Reactive separation of boron using a liquid membrane of diol in vegetable oil

  • Hossain, Md. M.;Maraqa, M.A.
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.19-34
    • /
    • 2017
  • Boron exists in dilute concentrations in sea water, ground water and waste waters. Reactive liquid extraction can be used for removing boron to make the treated water suitable for drinking and irrigation, with its final concentration less than 0.5 ppm. The results of equilibrium experiments are reported on the removal of boron using 2-butyl-2-ethyl-1, 3-propanediol (BEPD as a nonionic carrier) in sunflower oil, a non-traditional solvent. The results of removal of boron from aqueous solutions in the concentration range 0.5-20 ppm are presented. It is shown that this new liquid membrane system, is able to remove boron from ground waters at their natural pH of 6-8 (without any chemical addition for pH adjustments). The removal efficiency is good when the process is upgraded to a hollow-fibre membrane contactor and approximately 45% boron can be removed in a single-stage contact. There are additional advantages of this new approach that includes reduced operational health and safety and environmental issues. The results reported here provide guidelines to the development of boron removal process using renewable, biodegradable, safe and cheap solvent system such as sunflower oil.

Influence of Reaction Temperature on Bio-oil Production from Rice Straw by the Pyrolysis (볏짚으로부터 바이오오일 생산에 대한 열분해 반응온도의 영향)

  • Kang Bo-Sung;Park Young-Kwon;Kim Joo-Sik
    • Resources Recycling
    • /
    • 제15권1호
    • /
    • pp.12-19
    • /
    • 2006
  • Rice straw is one or the main renewable energy sources in Korea. Bio-oil is produced from rice straw with a lab-scale equipment mainly with a fluidized bed and a char removal system. It was investigated how the reaction temperature affected the production of bio-oil and the efficiency of a char removal system. To elucidate how the temperature depended on the production of bio-oil, experiments were conducted at $466^{\circ}C,\;504^{\circ}C\;and\;579^{\circ}C$, respectively. The mass balance was established in each experiment, and the produced gas and oil were analyzed with the aid of GCs and a GC-MS system. The char removal system is composed of a cyclone and a hot filter. Tn the experiments, we observed that the production of bio-oil was decreased with temperature, and the bio-oil contained very useful chemicals.

Influence of Reaction Temperature on the Pyrolytic Product of Rice Straw by Fast Pyrolysis using a Fluidized Bed (볏짚의 급속 열분해 생성물에 대한 반응온도의 영향)

  • Kang, Bo-Sung;Park, Young-Kwon;Kim, Joo-Sik
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 한국자원리싸이클링학회 2005년도 추계정기총회 및 제26회 학술발표대회 고분자리싸이클링기술 특별심포지엄
    • /
    • pp.47-58
    • /
    • 2005
  • Rice straw is one of the main renewable energy sources in Korea, and bio-oil is produced from rice straw with a lab. scale plant equipped mainly with a fluidized bed and a char removal system. We investigated how the reaction temperature affected the production of bio-oil and the efficiency of a char removal system. To elucidate how the temperature depended on the production of bio-oil, experiment were conducted between $450^{\circ}C\;and\;600^{\circ}C$ with a feed rate of about 300g/h. The mass balance was established in each experiment, and the produced gas and oil were analyzed with the aid of GCs and a GC-MS system. The char removal system is composed of a cyclone and a hot filter. In the experiments, we observed that the optimum reaction temperature range for the production of bio-oil is between $450^{\circ}C\;and\;500^{\circ}C$.

  • PDF

Ultrasonic flushing 기법에 의한 유류오염토양의 복원에 관한 실험연구

  • Jeong, Ha-Ik;Oh, In-Gyu;Kim, Sang-Geun;Lee, Yong-Su;Yoo, Jun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.13-17
    • /
    • 2002
  • Ultrasonic waves have several mechanical, chemical, and biological effects on a saturated soil medium. Their mechanical effects, popularly known as cavitation. Cavitation is the rapid and repeated formation, and resulting implosion, of imcrobubbles in a liquid, resulting in the propagation of microscopic shock waves. In a soil-liquid system, their mechanical effects generate high differntial fluid-particle velocities and microscopic shock waves. The velocity perturbations are capable of dislodging oil in the system by overcoming the forces binding oil to sand particles. In this study, a series of laboratory experiments involving the simple flushing and ultrasonic flushing were carried out. An increase in permeability and oil removal rate were observed in ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of ultrasonics.

  • PDF

Development of Oil Flushing System with Microbubble Generator (마이크로 버블 발생장치와 결합된 오일 플러싱 장치 개발)

  • Hong, Sung-Ho;Lee, Kyung-Hee;Jeong, Nam-Wha
    • Tribology and Lubricants
    • /
    • 제38권3호
    • /
    • pp.109-114
    • /
    • 2022
  • This paper reports the development of an oil flushing system combined with a microbubble generator. Oil flushing plays a crucial role in regulating the lubricant's performance during the lubricant replacement process. Moreover, harmful contaminants, such as sludge, wear particles, and rust, from piping systems or lubrication system can be removed by oil flushing. Oil flushing aims to increase the system's efficiency using a dedicated flushing oil, increasing of the supply pressure and generating a vortex. In addition, it helps the mechanical system or equipment achieve peak performance and reduces the potential for premature failure. However, the contaminant-removal applications of existing oil flushing system are limited. In this research, we aim to improve the performance of oil flushing system by incorporating a microbubble generator, which uses the venture effect to generate microbubbles and mixes them with lubricant. The microbubbles in the blended lubricant remove contaminants from the lubrication system more effectively. Structural mechanics and fluid dynamics are analyzed through fluid-structure interaction (FSI) analysis, and the numerical analysis results are used for the designing the system. The magnitude of the maximum stress is investigated based on the pressure results obtained by the CFD analysis; through the CFD analysis, the mixing ratio of air (bubble) and lubricant is evaluated using the volume of fluid (VOF) model according to the working conditions.

Treatment of ground waters in a hollow-fibre liquid membrane contactor for removal of ions

  • Hossain, Md. M.
    • Membrane and Water Treatment
    • /
    • 제4권2호
    • /
    • pp.95-108
    • /
    • 2013
  • Metal ions exist in seawater, groundwater and industrial wastewaters. These source waters can be recycled if their concentrations are reduced. A number of processes can be applied for this purpose. Liquid-liquid extraction is one of the promising methods. In this paper, experimental results are presented on the removal of Cr(VI) using Aliquat-336, a reactive carrier, in sunflower oil (a non-toxic solvent). The performance of this new system is compared with those of kerosene (a toxic solvent). The extent of removal of Cr(VI) from samples with high and low concentrations are presented. The process was upgraded to a bench-scale module that can selectively remove about 50-90% Cr(VI) from samples of groundwater. Thus this process can produce water within the acceptable range for recycling and for use in secondary purposes such as irrigation.

A Study on Treatment of a Contaminated Soil by Oil using Continuous System of High Temperature Heating Element and Microwave (마이크로웨이브와 고온발열체를 이용한 연속식 공정의 유류오염토양 처리에 관한 연구)

  • Ha, Sang-An;You, Mi-Young
    • Journal of Soil and Groundwater Environment
    • /
    • 제17권1호
    • /
    • pp.8-12
    • /
    • 2012
  • This study is maintains the condition of high temperature (above $600^{\circ}C$) within a short time using on microwave and high temperature heating elements. And removal characteristics according to changes in soil moisture, microwave power and temperature through the decomposition of the contaminated soil by oil. The difficulty resolvability material was sort of lubricating oil having long carbocyclic (C18-C50) and TPH removal rate reached 85.2% at 6 kW and $700^{\circ}C$ and thus the contaminant was removed 1,788 mg/kg within a process time of 40 minutes. In the case of light oil, gasoline contaminated soil, the removal amount showed 567 mg/kg and the treatment rate reached 98.4% at 6 kW, $500^{\circ}C$ and 20 minute. In the case of non-resolvability reached TPH concentrations on 2,000 mg/kg of worrisome level of soil contamination in the 3 zones at 6 kW, $700^{\circ}C$ and 30 minute. At the time, showed up processing costs 8,173 won per ton.

Design of Structured Surfaces for Directional Mobility of Droplets

  • Osada, Takehito;Kaneko, Arata;Moronuki, Nobuyuki;Kawaguchi, Tomoyo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.13-17
    • /
    • 2008
  • This paper deals with the directional mobility of droplets on structured surfaces. Structured surfaces were micro-patterned with rectangular lines and spaces of varying pitch and height in the sub-millimeter range. The material used was polydimethylsiloxane, which is hydrophobic and wettable by oil. First, we studied the effect of the structural design on the sliding angle of pure water or oil through experiments. For pure water droplets, we found that a wider pitch enhanced the directionality. On the other hand, oil droplets spread along the groove because of their low surface tension and strong capillary force. The directionality of the sliding angle of oil droplets was larger than that of pure water, especially when the groove was narrower and deeper. Second, we poured a large amount of liquid on the structure and evaluated the removal rate on the tilted surface. We found that a parallel structure enhanced the liquid mobility for both pure water and oil.