• Title/Summary/Keyword: Oil diagnosis

Search Result 163, Processing Time 0.021 seconds

Review on the Relationship of Dissolved Gas Analysis and Internal Inspection of Transformer (변압기 절연재료 분석과 내부점검 결과와의 상관성 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Jung, Nyun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1869-1873
    • /
    • 2010
  • For reliable operation of oil-filled electrical equipment, monitoring and maintenance of insulating oil is essential. Dissolved gas analysis(DGA) is widely used for monitoring faults in high voltage electrical equipment in service. Therefore, oil analysis should be monitored regularly during its service life. KEPCO has investigated thousands of dissolved gas analysis data since 1985, and conducted studies on the relationship of gas in oil analysis and internal inspection results of transformer. As the results, KEPCO revised criteria for transformer diagnosis and has applied it since 2008. Almost of 100 cases of internal inspection results since 2001 have been investigated. This paper presents the correlation of the fault-identifying gases with faults found in actual transformers and how should we approach to internal inspection of transformer by dissolved gas analysis.

Characteristics and Signal Analysis of Fiber-optic Sensor for Detecting Ultrasonic Waves Generated by Discharge in Insulation Oil (유중 방전에 의한 초음파 측정용 광섬유 센서 특성 및 측정 데이터 분석)

  • 이상훈;송현직;이광식;김달우
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.481-486
    • /
    • 2003
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

Monitoring method of transformer insulationg oil using pulsed-laser and photodiode (펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법)

  • Cho, J.S.;Yang, D.M.;An, K.S.;Yoon, S.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration (유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구)

  • Park, Jin-Yeub;Chin, Soo-Hwan;Park, In-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor (가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Choo, Y.B.;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

Quantitative Analysis of Fuel in Engine Oil (엔진오일 내 연료성분 정량분석)

  • Lim, Young-Kwan;Kim, Jiyeon;Na, Yong-Gyu;Kim, Jong-Ryeol
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.714-719
    • /
    • 2017
  • The contaminated engine oil by fuel can intimidate driver safety due to vehicle problems such as engine abrasion, fire and sudden unintended acceleration. In this study, we investigate various functional properties of the engine oil contaminated with fuel. The test results indicated that the engine oil contaminated with fuel had relatively low values of the flash point, pour point, density, kinematic viscosity and cold cranking simulator. Furthermore, a four ball test suggested that the contaminated engine oil increased wear scar due to the poor lubricity. Moreover, SIMDIST (simulated distillation) using ASTM D2887 was applied to analyze fuel characteristics in an engine oil. The SIMDIST analysis result showed a lower carbon number, and the fuel was detected at an earlier retention time than that of using engine oil in chromatogram. Also, it is possible to quantitatively analyze for fuel contents in the engine oil. The SIMDIST method for the diagnosis of oil conditions can be used whether the fuel was involved or not, instead of analyzing other physical properties that require various analytical instruments, large volumes of oil samples, and long analysis time.

Study of Condition Analysis and Diagnosis on Oil Paintings with Terahertz Imaging (테라헤르츠 이미징기법을 이용한 유화의 상태분석 및 진단)

  • Baek, Na Yeon;Song, You Na;Kim, Moon Jeong;Chung, Yong Jae;Lee, Han Hyoung
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.237-244
    • /
    • 2019
  • In this study, we applied terahertz imaging technology to three Korean modern oil paintings ('Boy,' 'Girl,' and 'Hyehwadong Landscape'); investigated the types of inner layer information in the pictures that can be extracted with terahertz imaging technology; and analyzed the conditions for extracting them. The biggest problem in the terahertz imaging analysis we encountered was the image distortion caused by the change of the distance between the target surface and the terahertz detector, depending on the surface curvature of the target paintings. We then developed a 'working distance maintaining device' to solve this problem. As a result, the terahertz imaging technique was used to identify the base material characteristics and any patterns of damage inside, and presented the optimal conditions for identifying each characteristic. In addition, it was useful to employ the terahertz frequency-division image to check the characteristics of the background materials. To confirm coloring techniques such as brush strokes, it is effective to compare the maximum reflection peak image with the cross-section image; and to detect damage information inside the paintings that cannot be observed on the surface, to compare the cross-section image with the frequency-division image. On the other hand, according to the terahertz imaging analysis of the oil paintings, the internal structural damage marks of 'Boy' and 'Girl' were confirmed, and the artist's painting style was confirmed in 'Hyehwadong Landscape.' The above results are expected to be useful for the analysis and diagnosis of Korean modern oil paintings for their preservation.

A Hybrid Type Based Expert System for Fault Diagnosis in Transformers (변압기 고장 진단을 위한 하이브리드형 전문가 시스템)

  • Jeon, Young-Jae;Yoon, Yong-Han;Kim, Jae-Chul;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.143-145
    • /
    • 1996
  • This paper presents the hybrid type based expert system for fault diagnosis in transformers. The proposed system uses the novel fault diagnostic technique based on dissolved gas analysis(DGA) in oil-immersed transformers. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set. Also, the uncertainty of the fault diagnostic rules are handled by using fuzzy measures. Finally, kohnen's feature map performs fault classification in transformers. To verify the effectiveness of the proposed diagnosis technique, the hybrid type based expert system for fault diagnosis has been tested by using KEPCO's transformer gas records.

  • PDF

A Case of Lipoid Pneumonia Induced by Aspiration of Shark Liver Oil (상어 간유 흡인에 의한 지방성 폐렴 1예)

  • Lee, Jin-Suk;Ju, Hong-Don;Han, Chang-Wan;Lee, Gwi-Lae;Cho, Yung-Sam;Park, Un-Slk;Jeong, Dong-Seong;Han, Jong-Hak;Kim, Jae-Hong;Son, Yong-Woo;Roh, Yong-Ho;Kim, Jeong-Lae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.670-675
    • /
    • 1994
  • Lipoid pneumonia is a chronic inflammatory reaction of the lungs that results from the aspiration of vegetable, animal, or mineral oils. The most frequently implicated agent is mineral oil used as a laxative and to reduce dysphagia. Lipoid pneumonia is suggested when there is a history of chronic oral or intranasal use of an oil- or lipid-based product. The characteristic findings of lipid materials in CT or MRI are used in the diagnosis of lipoid pneumonia. The presence of lipid-laden macrophages in the sputum, bronchoalveolar larvage or pulmonary parenchymal biopsy confirms the diagnosis. Sputum study is simple and inexpensive. We report a case of lipoid pneumonia of 75 year old male with cough and sputum, confirmed by sputum study, and review the literature.

  • PDF

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.