• Title/Summary/Keyword: Oil and gas

Search Result 2,000, Processing Time 0.038 seconds

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

A Study on the Quantitative Risk Analysis Using CFD for the Fuel Gas Supply System of Gas Fueled Ship (가스추진선박의 가스연료공급시스템에 대한 CFD를 이용한 정량적 위험도 해석에 관한 연구)

  • Kim, Kipyoung;Kim, Daeheon;Lee, Youngho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • LNG has significant advantages in regard to environmental aspects comparing with conventional fuel oil. In fact, it is estimated that NOx and SOx emission can be reduced by about 90% and 100%, respectively in case of using LNG as a fuel. LNG-fuelled ship has been considered to be the best option both from an environmental and an economic point of view. Along with these trends, some major shipyards and Classification Societies have started to carry out the risk-based system design for LNG-fuelled ship such as passenger ship, platform supply vessel and large container vessel etc. However, new conceptual gas fuelled ship has high risk level compared with vessel using traditional crude oil especially in view of gas explosion accident. Therefore safety area where installed fuel gas supply system is required risk based system design with special considerations. On this paper, the entire process necessary for the quantitative risk analysis was explained to meet the satisfactory safety level of gas fuelled ship.

A Numerical investigation of Oil Jet in an Engine Piston (피스톤 냉각용 Oil Jet 유동 수치해석)

  • Li, Li;Kwon, Ji-Hyuk;Jung, Ho-Yun;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.33-34
    • /
    • 2005
  • The internal state of an automotive engine is very severe. A piston exposes burnt gas of over $2000^{\circ}$ nd is shocked by high pressure at the time of explosion. Furthermore strong friction is caused by high speed motion. A study on the cooling of the piston requires because the cooling and lubrication of the piston has an effect on the life and efficiency of engine directly. The previous system of oil jet cooled only the bottom of the piston. In order to improve the cooling efficiency, the oil gallery is made inside the piston, and oil flows into the oil gallery. The flow rate of oil at the entrance of oil gallery is important because of the cooling efficiency. The purpose of this study is the investigation of fluid flow characteristics of oil jet and flow rate into the oil gallery.

  • PDF

A Study on the Performance of Small Diesel Engine Using Blend Fuel Oil ( 3 ) - Rape Seed Oil 20 % and Diesel Oil 80 % - (혼합 연료를 사용한 소형 디이젤 기관의 성능에 관한 연구 ( 3 ) - 유연기름 20 % 와 디이젤유 80 % -)

  • 고장권
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.2
    • /
    • pp.127-132
    • /
    • 1984
  • Performance tests of small diesel engine were carried out, using the blend fuel oil as the substitute fuel oil and the following results were obtained. (1) The character at the blend oil as substitute fuel for small diesel engine was examined. (2) In the case of operating small diesel engine with blend oil, the exhaust gas volume increases at 8% in comparison with diesel oil. (3) In the case of operating small diesel engine with blend oil, the fuel consumption Increases at 3% in comparison with diesel oil. (4) In the brake thermal efficiency, blend oil is similar to diesel oil.

  • PDF

The Intrinsic Safety Evaluation of Solar Photovoltaic Cell (태양전지셀의 본질안전 방폭성능 평가)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Si-Kuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

Measurement of two dimensional oil film thickness in piston by induced fluorescence method (유기형광법을 이용한 피스톤 유막두께의 이차원적 측정)

  • 민병순;최재권
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Analysis of Sterols and Its Hydrogenation to Stanols in Vegetable Oils for the Development of a Cholesterol Absorption-lowering Neutraceutical (콜레스테롤 흡수저하 기능성소재 개발을 위한 식물성 유지 중이 Sterols 분석 및 Stanol로의 수소첨가반응)

  • 인만진;김동청;채희정;김명희;임병순;김의용
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.5
    • /
    • pp.980-983
    • /
    • 1999
  • The contents of sterols and stanols in vegetable oils and mist oil were analyzed by gas chromatography using a capillary column. The total sterol contents showed high values of 0.67~0.89g/100g in corn oil, rice bran oil, red pepper seed oil and sesame oil. Mist oil, a byproduct of soybean oil manufacture, was a suitable raw material for the production of stanol since it showed high sterol content (10.2g/100g). In the hydrogenation of sterol contained in mist oil using Pd catalyst, the effects saponification of oil were examined. The conversion of sterol to stanol was improved by a factor of 4~5 through saponification of oil, compared to the reaction without saponification.

  • PDF

Development of Greenhouse Gas Emission Factor of B-C Oil Fired Power Plants in Korea (우리나라 B-C유 사용 발전시설의 온실가스 배출계수 개발)

  • Kim, Jinsu;Lee, Seehyung;Myeong, Soojeong;Jeong, Jae-Hak;Lee, Seongho;Kim, Ki-Hyun;Bae, Wisup;Jeon, Eui-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.2
    • /
    • pp.69-78
    • /
    • 2009
  • In order to provide fundamental data for developing greenhouse gas emission factor, we investigated power plants in Korea using B-C oil as Energy source. The power plant is a major source of greenhouse gases among the sectors of fossil fuel combustion, thus information of its emission factors is very essential to the establishment of control strategies for the greenhouse gas emissions. The caloric value of fuel was analyzed using calorimeter and the calorific value was 10,419 kcal/kg. The $CO_2$ concentration of flue gas and elemental analysis were conducted using GC-FID and elemental analyzer. The $CO_2$ emission factors from fuel analysis was 75,410 kg/TJ and that from $CO_2$ gas analysis was 94,265 kg/TJ. When compared with IPCC values, the emission factors by the fuel analysis was 2.5% lower, and that by $CO_2$ gas analysis was about 21.85% higher.

An Implementation for Oil Mixing Preventive Device and Time Indicator (혼유 주유 방지 및 세차 대기 표시기 구현)

  • Kim, Seong-Jin;Sunwoo, Yong-Woon;Lee, Sung-Hyun;Lee, Jung-Woong;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.191-198
    • /
    • 2019
  • In this paper, we implemented the prevention of oil mixing accidents caused by stereotypes or novice drivers at gas stations. After the CO gas concentration of the fuel tank is measured using the MQ-9 gas sensor, the gasoline and diesel are distinguished from each other. This is decided by using a servomotor to lock of the fueling nozzle to prevent the mixing of oil. In addition, car washes time display is implemented by using infrared sensor to save the time and to provide convenience for customers who want to wash car after fueling.

Pyrolysis Characteristics of Waste Ship Lubricating Oil using Waste Catalyst in Isothermal Tubular Type Pyrolysis Reactor (등온 열분해 반응기에서 폐촉매를 이용한 선박용 폐윤활유의 열분해반응 특성 연구)

  • Kim, Seung-Soo
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.511-515
    • /
    • 2007
  • The yield of oil was rapidly increased at $440^{\circ}C$ compared to $400^{\circ}C$ and $420^{\circ}C$ when the isothermal pyrolysis of waste ship lubricating oil was carried out in tubular type reactor, and pyrolysis was almost finished within 30 min. The yield of gas was decreased depending on the reaction temperature in which that of solid was not much changed. Pyrolysis experiments of waste ship lubricating oil were carried out with used ZSM-5 produced from a petrochemical process. The yield of gas was highly increased in the case of used ZSM-5 and fresh ZSM-5 compared to the case without catalyst. The produced oil and gas were almost constant for fresh ZSM-5 and used ZSM-5 at the same reaction temperature. In the reaction temperature $400{\sim}440^{\circ}C$, the selectivity of $C_5-C_{11}$ was two times higher with fresh ZSM-5 and used ZSM-5 than the case without catalyst.